Loading…

A time-dependent dose model for glovebox processing of fissile material

A new modeling system for high-intensity neutral particle radiation fields is presented. The code PANDEMONIUM calculates external effective dose rates from neutrons and photons produced at specific locations within an industrial-size plutonium processing facility. The new version of PANDEMONIUM intr...

Full description

Saved in:
Bibliographic Details
Published in:Radiation protection dosimetry 2005-01, Vol.115 (1-4), p.350-356
Main Authors: Wooten, H. Omar, Dudziak, Donald J., Hertel, Nolan E., Kornreich, Drew E.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:A new modeling system for high-intensity neutral particle radiation fields is presented. The code PANDEMONIUM calculates external effective dose rates from neutrons and photons produced at specific locations within an industrial-size plutonium processing facility. The new version of PANDEMONIUM introduces time-dependent neutronics for source multiplication coupled with transient source and detector positions. The code is designed to provide quick and acceptably accurate total effective dose estimates for scenarios and facilities for which conventional methods prove to be too impractical or costly to model. The energy range of the code has also been extended to include the effects of prompt-fission photons.