A quick laboratory X-ray reflectometer for time-resolved observations
Abstract only The measurement of the X-ray reflectivity curve is a widely used method to obtain structural information about thin films, surfaces and interfaces. With conventional instruments, the reflectivity curve is measured sequentially for a range of incident angles, which takes a long time. A...
Saved in:
Published in: | Acta crystallographica. Section A, Foundations and advances Foundations and advances, 2014-08, Vol.70 (a1), p.C884-C884 |
---|---|
Main Authors: | , , , , , |
Format: | Article |
Language: | English |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Abstract only The measurement of the X-ray reflectivity curve is a widely used method to obtain structural information about thin films, surfaces and interfaces. With conventional instruments, the reflectivity curve is measured sequentially for a range of incident angles, which takes a long time. A recently developed method using white synchrotron radiation can measure the whole curve at once [1, 2]. In this contribution, the adaption of this method to a laboratory characteristic X-ray source is presented. This will make it possible to do time-resolved or high-throughput measurements using standard laboratory sources. The basic idea of our method is to focus the divergent X-ray beam emitted from a point source with either a doubly-curved Si crystal monochromator or a bent-twisted Si crystal monochromator [1]. Instead of using the whole beam, however, only the fan-shaped beam from a diagonal line on the monochromator is focused onto the sample. This is realized by placing an inclined slit before the monochoromator. The beam reflected from the sample forms a line on a two-dimensional pixel array detector. For each horizontal position on the detector, the incident angle onto the sample, and therefore the momentum transfer, is different. The reflectivity curve for a range of momentum transfers can therefore be measured with a single detector exposure without moving the sample, monochromator or detector. Reflectivity curves from a silicon wafer sample measured by our method are compared with the conventional angle scan method in the figure. The reflectivity down to 10 to the -7th power can be obtained, because the background can be subtracted from the measured intensity. We will show an example of time-resolved (10 s) measurements of specular X-ray reflectivity curves. We will also discuss the momentum transfer range that can be measured simultaneously and factors limiting the resolution of the method. |
---|---|
ISSN: | 2053-2733 2053-2733 |
DOI: | 10.1107/S2053273314091153 |