Loading…

Computational comparison of AC losses in different kinds of HTS composite conductors

AC losses of different kinds of available or anticipated HTS composite conductors were computed by using a magnetic diffusion model. The model takes into account the real current density-electric field characteristic of the superconductor and the spatial dependence of the current density, The comput...

Full description

Saved in:
Bibliographic Details
Published in:IEEE transactions on applied superconductivity 1997-06, Vol.7 (2), p.322-325
Main Authors: Paasi, J., Lahtinen, M.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:AC losses of different kinds of available or anticipated HTS composite conductors were computed by using a magnetic diffusion model. The model takes into account the real current density-electric field characteristic of the superconductor and the spatial dependence of the current density, The computation was carried out for self-field losses due to transport current ramps and for magnetization losses in magnet operation due to ramping external magnetic field. Special attention was paid to filament coupling in various conductor models at different ramp rates.
ISSN:1051-8223
1558-2515
DOI:10.1109/77.614495