Correction of Deflection Defocusing in Cathode-Ray Tubes

This investigation deals with the problem of minimizing spot distortion by suitable design of the deflecting plates in a cathode-ray tube with electrostatic deflection. The treatment is mathematical throughout. A number of the results obtained may be applicable to a much wider range of problems. A n...

Full description

Saved in:
Bibliographic Details
Published in:Proceedings of the IRE 1951-01, Vol.39 (1), p.10-15
Main Author: Rosenthal, J.E.
Format: Article
Language:English
Subjects:
Citations: Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:This investigation deals with the problem of minimizing spot distortion by suitable design of the deflecting plates in a cathode-ray tube with electrostatic deflection. The treatment is mathematical throughout. A number of the results obtained may be applicable to a much wider range of problems. A number of special design formulas are given which solve the problem satisfactorily.