Correction of Deflection Defocusing in Cathode-Ray Tubes
This investigation deals with the problem of minimizing spot distortion by suitable design of the deflecting plates in a cathode-ray tube with electrostatic deflection. The treatment is mathematical throughout. A number of the results obtained may be applicable to a much wider range of problems. A n...
Saved in:
Published in: | Proceedings of the IRE 1951-01, Vol.39 (1), p.10-15 |
---|---|
Main Author: | |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | This investigation deals with the problem of minimizing spot distortion by suitable design of the deflecting plates in a cathode-ray tube with electrostatic deflection. The treatment is mathematical throughout. A number of the results obtained may be applicable to a much wider range of problems. A number of special design formulas are given which solve the problem satisfactorily. |
---|---|
ISSN: | 0096-8390 2162-6634 |
DOI: | 10.1109/JRPROC.1951.230414 |