Loading…

A Hall Probe Calibration System at Low Temperature for the TPS Cryogenic Permanent Magnet Undulator

A cryogenic permanent-magnet undulator (CPMU) with a 15-mm period length is being constructed for the TPS. Field measurements of this undulator will be performed with a Hall probe at cryogenic temperatures, for which a field strength and temperature-dependent calibration system is necessary. This sy...

Full description

Saved in:
Bibliographic Details
Published in:IEEE transactions on applied superconductivity 2018-04, Vol.28 (3), p.1-5
Main Authors: Chin-Kang Yang, Wen-Hsuan Hsieh, Yun-Liang Chu, Chang, C. H., Cheng-Ying Kuo, Sei-Da Chen, Jui-Che Huang, Ching-Shiang Hwang
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c265t-f34504cb6bcdb6e12116e2941e9a8d82fedc591e1133f688eecf707e3fd796073
cites cdi_FETCH-LOGICAL-c265t-f34504cb6bcdb6e12116e2941e9a8d82fedc591e1133f688eecf707e3fd796073
container_end_page 5
container_issue 3
container_start_page 1
container_title IEEE transactions on applied superconductivity
container_volume 28
creator Chin-Kang Yang
Wen-Hsuan Hsieh
Yun-Liang Chu
Chang, C. H.
Cheng-Ying Kuo
Sei-Da Chen
Jui-Che Huang
Ching-Shiang Hwang
description A cryogenic permanent-magnet undulator (CPMU) with a 15-mm period length is being constructed for the TPS. Field measurements of this undulator will be performed with a Hall probe at cryogenic temperatures, for which a field strength and temperature-dependent calibration system is necessary. This system consists of a cryo-cooler and a heater to control the Hall probe temperature, a home-made dipole electromagnet, a nuclear magnetic resonant Tesla meter, and two angle adjusting stages. These stages will rotate the Hall probe to adjust the angular accuracy of the Hall probe axes with respect to a reference ceramic surface and to measure the planar Hall effect coefficient. A two-axis compact 0.9-mm SENIS Hall probe is used in the very small gap of 4 mm of this CPMU. Design details and performance of this system, its calibrating process, and calibration results at various temperatures will be discussed in this paper.
doi_str_mv 10.1109/TASC.2018.2795575
format article
fullrecord <record><control><sourceid>crossref_ieee_</sourceid><recordid>TN_cdi_crossref_primary_10_1109_TASC_2018_2795575</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>8264773</ieee_id><sourcerecordid>10_1109_TASC_2018_2795575</sourcerecordid><originalsourceid>FETCH-LOGICAL-c265t-f34504cb6bcdb6e12116e2941e9a8d82fedc591e1133f688eecf707e3fd796073</originalsourceid><addsrcrecordid>eNo9kN9KwzAYxYMoOKcPIN7kBTrzJU2TXo6ibjBxsO66pOmXWWmbkWbI3t6NDa_OgfPn4kfIM7AZAMtfy_mmmHEGesZVLqWSN2QCUuqES5C3J88kJJpzcU8exvGHMUh1KifEzunCdB1dB18jLUzX1sHE1g90cxwj9tREuvK_tMR-j6fkEJA6H2j8RlquN7QIR7_DobV0jaE3Aw6RfprdgJFuh-bQmejDI7lzphvx6apTsn1_K4tFsvr6WBbzVWJ5JmPiRCpZauustk2dIXCADHmeAuZGN5o7bKzMAQGEcJnWiNYpplC4RuUZU2JK4PJrgx_HgK7ah7Y34VgBq86UqjOl6kypulI6bV4umxYR__uaZ6lSQvwBxcVkIQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>A Hall Probe Calibration System at Low Temperature for the TPS Cryogenic Permanent Magnet Undulator</title><source>IEEE Xplore (Online service)</source><creator>Chin-Kang Yang ; Wen-Hsuan Hsieh ; Yun-Liang Chu ; Chang, C. H. ; Cheng-Ying Kuo ; Sei-Da Chen ; Jui-Che Huang ; Ching-Shiang Hwang</creator><creatorcontrib>Chin-Kang Yang ; Wen-Hsuan Hsieh ; Yun-Liang Chu ; Chang, C. H. ; Cheng-Ying Kuo ; Sei-Da Chen ; Jui-Che Huang ; Ching-Shiang Hwang</creatorcontrib><description>A cryogenic permanent-magnet undulator (CPMU) with a 15-mm period length is being constructed for the TPS. Field measurements of this undulator will be performed with a Hall probe at cryogenic temperatures, for which a field strength and temperature-dependent calibration system is necessary. This system consists of a cryo-cooler and a heater to control the Hall probe temperature, a home-made dipole electromagnet, a nuclear magnetic resonant Tesla meter, and two angle adjusting stages. These stages will rotate the Hall probe to adjust the angular accuracy of the Hall probe axes with respect to a reference ceramic surface and to measure the planar Hall effect coefficient. A two-axis compact 0.9-mm SENIS Hall probe is used in the very small gap of 4 mm of this CPMU. Design details and performance of this system, its calibrating process, and calibration results at various temperatures will be discussed in this paper.</description><identifier>ISSN: 1051-8223</identifier><identifier>EISSN: 1558-2515</identifier><identifier>DOI: 10.1109/TASC.2018.2795575</identifier><identifier>CODEN: ITASE9</identifier><language>eng</language><publisher>IEEE</publisher><subject>Calibration ; cryogenic permanent-magnet undulator ; Hall-probe calibration ; Low temperature ; Magnetic field measurement ; magnetic field measurements in vacuum ; Magnetic fields ; Probes ; Superconducting magnets ; Temperature measurement ; Temperature sensors</subject><ispartof>IEEE transactions on applied superconductivity, 2018-04, Vol.28 (3), p.1-5</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c265t-f34504cb6bcdb6e12116e2941e9a8d82fedc591e1133f688eecf707e3fd796073</citedby><cites>FETCH-LOGICAL-c265t-f34504cb6bcdb6e12116e2941e9a8d82fedc591e1133f688eecf707e3fd796073</cites><orcidid>0000-0002-4943-1253 ; 0000-0003-4211-9985 ; 0000-0002-0225-4018 ; 0000-0001-8525-3506 ; 0000-0003-3558-2787 ; 0000-0003-0121-2008</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/8264773$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>314,780,784,27924,27925,54796</link.rule.ids></links><search><creatorcontrib>Chin-Kang Yang</creatorcontrib><creatorcontrib>Wen-Hsuan Hsieh</creatorcontrib><creatorcontrib>Yun-Liang Chu</creatorcontrib><creatorcontrib>Chang, C. H.</creatorcontrib><creatorcontrib>Cheng-Ying Kuo</creatorcontrib><creatorcontrib>Sei-Da Chen</creatorcontrib><creatorcontrib>Jui-Che Huang</creatorcontrib><creatorcontrib>Ching-Shiang Hwang</creatorcontrib><title>A Hall Probe Calibration System at Low Temperature for the TPS Cryogenic Permanent Magnet Undulator</title><title>IEEE transactions on applied superconductivity</title><addtitle>TASC</addtitle><description>A cryogenic permanent-magnet undulator (CPMU) with a 15-mm period length is being constructed for the TPS. Field measurements of this undulator will be performed with a Hall probe at cryogenic temperatures, for which a field strength and temperature-dependent calibration system is necessary. This system consists of a cryo-cooler and a heater to control the Hall probe temperature, a home-made dipole electromagnet, a nuclear magnetic resonant Tesla meter, and two angle adjusting stages. These stages will rotate the Hall probe to adjust the angular accuracy of the Hall probe axes with respect to a reference ceramic surface and to measure the planar Hall effect coefficient. A two-axis compact 0.9-mm SENIS Hall probe is used in the very small gap of 4 mm of this CPMU. Design details and performance of this system, its calibrating process, and calibration results at various temperatures will be discussed in this paper.</description><subject>Calibration</subject><subject>cryogenic permanent-magnet undulator</subject><subject>Hall-probe calibration</subject><subject>Low temperature</subject><subject>Magnetic field measurement</subject><subject>magnetic field measurements in vacuum</subject><subject>Magnetic fields</subject><subject>Probes</subject><subject>Superconducting magnets</subject><subject>Temperature measurement</subject><subject>Temperature sensors</subject><issn>1051-8223</issn><issn>1558-2515</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2018</creationdate><recordtype>article</recordtype><recordid>eNo9kN9KwzAYxYMoOKcPIN7kBTrzJU2TXo6ibjBxsO66pOmXWWmbkWbI3t6NDa_OgfPn4kfIM7AZAMtfy_mmmHEGesZVLqWSN2QCUuqES5C3J88kJJpzcU8exvGHMUh1KifEzunCdB1dB18jLUzX1sHE1g90cxwj9tREuvK_tMR-j6fkEJA6H2j8RlquN7QIR7_DobV0jaE3Aw6RfprdgJFuh-bQmejDI7lzphvx6apTsn1_K4tFsvr6WBbzVWJ5JmPiRCpZauustk2dIXCADHmeAuZGN5o7bKzMAQGEcJnWiNYpplC4RuUZU2JK4PJrgx_HgK7ah7Y34VgBq86UqjOl6kypulI6bV4umxYR__uaZ6lSQvwBxcVkIQ</recordid><startdate>201804</startdate><enddate>201804</enddate><creator>Chin-Kang Yang</creator><creator>Wen-Hsuan Hsieh</creator><creator>Yun-Liang Chu</creator><creator>Chang, C. H.</creator><creator>Cheng-Ying Kuo</creator><creator>Sei-Da Chen</creator><creator>Jui-Che Huang</creator><creator>Ching-Shiang Hwang</creator><general>IEEE</general><scope>97E</scope><scope>RIA</scope><scope>RIE</scope><scope>AAYXX</scope><scope>CITATION</scope><orcidid>https://orcid.org/0000-0002-4943-1253</orcidid><orcidid>https://orcid.org/0000-0003-4211-9985</orcidid><orcidid>https://orcid.org/0000-0002-0225-4018</orcidid><orcidid>https://orcid.org/0000-0001-8525-3506</orcidid><orcidid>https://orcid.org/0000-0003-3558-2787</orcidid><orcidid>https://orcid.org/0000-0003-0121-2008</orcidid></search><sort><creationdate>201804</creationdate><title>A Hall Probe Calibration System at Low Temperature for the TPS Cryogenic Permanent Magnet Undulator</title><author>Chin-Kang Yang ; Wen-Hsuan Hsieh ; Yun-Liang Chu ; Chang, C. H. ; Cheng-Ying Kuo ; Sei-Da Chen ; Jui-Che Huang ; Ching-Shiang Hwang</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c265t-f34504cb6bcdb6e12116e2941e9a8d82fedc591e1133f688eecf707e3fd796073</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2018</creationdate><topic>Calibration</topic><topic>cryogenic permanent-magnet undulator</topic><topic>Hall-probe calibration</topic><topic>Low temperature</topic><topic>Magnetic field measurement</topic><topic>magnetic field measurements in vacuum</topic><topic>Magnetic fields</topic><topic>Probes</topic><topic>Superconducting magnets</topic><topic>Temperature measurement</topic><topic>Temperature sensors</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Chin-Kang Yang</creatorcontrib><creatorcontrib>Wen-Hsuan Hsieh</creatorcontrib><creatorcontrib>Yun-Liang Chu</creatorcontrib><creatorcontrib>Chang, C. H.</creatorcontrib><creatorcontrib>Cheng-Ying Kuo</creatorcontrib><creatorcontrib>Sei-Da Chen</creatorcontrib><creatorcontrib>Jui-Che Huang</creatorcontrib><creatorcontrib>Ching-Shiang Hwang</creatorcontrib><collection>IEEE All-Society Periodicals Package (ASPP) 2005-present</collection><collection>IEEE All-Society Periodicals Package (ASPP) 1998-Present</collection><collection>IEEE Electronic Library Online</collection><collection>CrossRef</collection><jtitle>IEEE transactions on applied superconductivity</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Chin-Kang Yang</au><au>Wen-Hsuan Hsieh</au><au>Yun-Liang Chu</au><au>Chang, C. H.</au><au>Cheng-Ying Kuo</au><au>Sei-Da Chen</au><au>Jui-Che Huang</au><au>Ching-Shiang Hwang</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A Hall Probe Calibration System at Low Temperature for the TPS Cryogenic Permanent Magnet Undulator</atitle><jtitle>IEEE transactions on applied superconductivity</jtitle><stitle>TASC</stitle><date>2018-04</date><risdate>2018</risdate><volume>28</volume><issue>3</issue><spage>1</spage><epage>5</epage><pages>1-5</pages><issn>1051-8223</issn><eissn>1558-2515</eissn><coden>ITASE9</coden><abstract>A cryogenic permanent-magnet undulator (CPMU) with a 15-mm period length is being constructed for the TPS. Field measurements of this undulator will be performed with a Hall probe at cryogenic temperatures, for which a field strength and temperature-dependent calibration system is necessary. This system consists of a cryo-cooler and a heater to control the Hall probe temperature, a home-made dipole electromagnet, a nuclear magnetic resonant Tesla meter, and two angle adjusting stages. These stages will rotate the Hall probe to adjust the angular accuracy of the Hall probe axes with respect to a reference ceramic surface and to measure the planar Hall effect coefficient. A two-axis compact 0.9-mm SENIS Hall probe is used in the very small gap of 4 mm of this CPMU. Design details and performance of this system, its calibrating process, and calibration results at various temperatures will be discussed in this paper.</abstract><pub>IEEE</pub><doi>10.1109/TASC.2018.2795575</doi><tpages>5</tpages><orcidid>https://orcid.org/0000-0002-4943-1253</orcidid><orcidid>https://orcid.org/0000-0003-4211-9985</orcidid><orcidid>https://orcid.org/0000-0002-0225-4018</orcidid><orcidid>https://orcid.org/0000-0001-8525-3506</orcidid><orcidid>https://orcid.org/0000-0003-3558-2787</orcidid><orcidid>https://orcid.org/0000-0003-0121-2008</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 1051-8223
ispartof IEEE transactions on applied superconductivity, 2018-04, Vol.28 (3), p.1-5
issn 1051-8223
1558-2515
language eng
recordid cdi_crossref_primary_10_1109_TASC_2018_2795575
source IEEE Xplore (Online service)
subjects Calibration
cryogenic permanent-magnet undulator
Hall-probe calibration
Low temperature
Magnetic field measurement
magnetic field measurements in vacuum
Magnetic fields
Probes
Superconducting magnets
Temperature measurement
Temperature sensors
title A Hall Probe Calibration System at Low Temperature for the TPS Cryogenic Permanent Magnet Undulator
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-23T23%3A09%3A04IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-crossref_ieee_&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20Hall%20Probe%20Calibration%20System%20at%20Low%20Temperature%20for%20the%20TPS%20Cryogenic%20Permanent%20Magnet%20Undulator&rft.jtitle=IEEE%20transactions%20on%20applied%20superconductivity&rft.au=Chin-Kang%20Yang&rft.date=2018-04&rft.volume=28&rft.issue=3&rft.spage=1&rft.epage=5&rft.pages=1-5&rft.issn=1051-8223&rft.eissn=1558-2515&rft.coden=ITASE9&rft_id=info:doi/10.1109/TASC.2018.2795575&rft_dat=%3Ccrossref_ieee_%3E10_1109_TASC_2018_2795575%3C/crossref_ieee_%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c265t-f34504cb6bcdb6e12116e2941e9a8d82fedc591e1133f688eecf707e3fd796073%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=8264773&rfr_iscdi=true