Loading…
An Automated Noncontact Measurement System for Current Harmonics in Aerial Transmission and Distribution Systems
Using magnetic field data from under aerial power transmission lines, tomographic reconstruction techniques have been applied to determine the magnitudes and phases of currents in each power conductor. Phasor current values at fundamental (60 Hz) and harmonic frequencies are produced. This measureme...
Saved in:
Published in: | IEEE transactions on instrumentation and measurement 1984-01, Vol.33 (1), p.31-36 |
---|---|
Main Authors: | , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Using magnetic field data from under aerial power transmission lines, tomographic reconstruction techniques have been applied to determine the magnitudes and phases of currents in each power conductor. Phasor current values at fundamental (60 Hz) and harmonic frequencies are produced. This measurement technique requires no physical contact with power lines (even by clamp-around transformers) and hence should be convenient for monitoring and trouble-shooting cases of excessive harmonic currents on transmission and distribution facilities. The method has been implemented experimentally, and laboratory and initial field tests have demonstrated its basic validity. |
---|---|
ISSN: | 0018-9456 1557-9662 |
DOI: | 10.1109/TIM.1984.4315147 |