Loading…

Harmonic Distortions on Grid Connected Double Fed Generator: A Review

There are a number of distortions that affect the correct operation of a wind energy conversion system, among them one of the most significant is the presence of harmonics, which can lead to power or torque pulsations, overheating and increased losses in the stator windings, low power factor, etc. A...

Full description

Saved in:
Bibliographic Details
Published in:Revista IEEE América Latina 2016-04, Vol.14 (4), p.1745-1751
Main Authors: Lopez, A., Mina, J., Cardenas, V., De Leon, S., Calderon, G., Alquicira, J. A.
Format: Article
Language:English
Subjects:
Citations: Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c254t-95a69974663f516efb20e3c7f796ae0a66bfdac7d404b7737371973229805a623
cites
container_end_page 1751
container_issue 4
container_start_page 1745
container_title Revista IEEE América Latina
container_volume 14
creator Lopez, A.
Mina, J.
Cardenas, V.
De Leon, S.
Calderon, G.
Alquicira, J. A.
description There are a number of distortions that affect the correct operation of a wind energy conversion system, among them one of the most significant is the presence of harmonics, which can lead to power or torque pulsations, overheating and increased losses in the stator windings, low power factor, etc. According to the literature, the harmonic sources in a wind energy conversion system can be classified from the grid and harmonics produced in the wind energy conversion system. This paper presents a review about the solutions for harmonic distortions on grid connected double fed generator based in a back to back converter. The techniques employed to reduce the harmonic contamination to the grid in both scenarios are reviewed.
doi_str_mv 10.1109/TLA.2016.7483510
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1109_TLA_2016_7483510</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>7483510</ieee_id><sourcerecordid>1825489980</sourcerecordid><originalsourceid>FETCH-LOGICAL-c254t-95a69974663f516efb20e3c7f796ae0a66bfdac7d404b7737371973229805a623</originalsourceid><addsrcrecordid>eNpdkM9LwzAYhoMoOKd3wUvAi5fOpGmTxtvofgkDQeY5pO1XyOiSmbSK_70ZmyKSQ17I8-b7eBC6pWRCKZGPm_V0khLKJyIrWE7JGRrRPCsSImV6_idfoqsQtoSwghdshOYr7XfOmhrPTOid742zATuLl940uHTWQt1Dg2duqDrAixiXYMHryD7hKX6FDwOf1-ii1V2Am9M9Rm-L-aZcJeuX5XM5XSd1mmd9InPNpRQZ56zNKYe2SgmwWrRCcg1Ec161ja5Fk5GsEoLFQ6VgaSoLEqspG6OH4797794HCL3amVBD12kLbgiKFnFOISMe0ft_6NYN3sbtFBWSMZHLKGCMyJGqvQvBQ6v23uy0_1KUqINXFb2qg1d18hord8eKAYBf_Of1Gxt3cNs</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1793375968</pqid></control><display><type>article</type><title>Harmonic Distortions on Grid Connected Double Fed Generator: A Review</title><source>IEEE Xplore (Online service)</source><creator>Lopez, A. ; Mina, J. ; Cardenas, V. ; De Leon, S. ; Calderon, G. ; Alquicira, J. A.</creator><creatorcontrib>Lopez, A. ; Mina, J. ; Cardenas, V. ; De Leon, S. ; Calderon, G. ; Alquicira, J. A.</creatorcontrib><description>There are a number of distortions that affect the correct operation of a wind energy conversion system, among them one of the most significant is the presence of harmonics, which can lead to power or torque pulsations, overheating and increased losses in the stator windings, low power factor, etc. According to the literature, the harmonic sources in a wind energy conversion system can be classified from the grid and harmonics produced in the wind energy conversion system. This paper presents a review about the solutions for harmonic distortions on grid connected double fed generator based in a back to back converter. The techniques employed to reduce the harmonic contamination to the grid in both scenarios are reviewed.</description><identifier>ISSN: 1548-0992</identifier><identifier>EISSN: 1548-0992</identifier><identifier>DOI: 10.1109/TLA.2016.7483510</identifier><language>eng</language><publisher>Los Alamitos: IEEE</publisher><subject>Automatic voltage control ; back to back ; Coils (windings) ; Conversion ; DFIG ; Distortion ; Generators ; Harmonic analysis ; Harmonic distortion ; Harmonics ; Power system harmonics ; Pulsation ; Rotors ; WECS ; Wind energy</subject><ispartof>Revista IEEE América Latina, 2016-04, Vol.14 (4), p.1745-1751</ispartof><rights>Copyright The Institute of Electrical and Electronics Engineers, Inc. (IEEE) 2016</rights><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c254t-95a69974663f516efb20e3c7f796ae0a66bfdac7d404b7737371973229805a623</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/7483510$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>314,780,784,27924,27925,54796</link.rule.ids></links><search><creatorcontrib>Lopez, A.</creatorcontrib><creatorcontrib>Mina, J.</creatorcontrib><creatorcontrib>Cardenas, V.</creatorcontrib><creatorcontrib>De Leon, S.</creatorcontrib><creatorcontrib>Calderon, G.</creatorcontrib><creatorcontrib>Alquicira, J. A.</creatorcontrib><title>Harmonic Distortions on Grid Connected Double Fed Generator: A Review</title><title>Revista IEEE América Latina</title><addtitle>T-LA</addtitle><description>There are a number of distortions that affect the correct operation of a wind energy conversion system, among them one of the most significant is the presence of harmonics, which can lead to power or torque pulsations, overheating and increased losses in the stator windings, low power factor, etc. According to the literature, the harmonic sources in a wind energy conversion system can be classified from the grid and harmonics produced in the wind energy conversion system. This paper presents a review about the solutions for harmonic distortions on grid connected double fed generator based in a back to back converter. The techniques employed to reduce the harmonic contamination to the grid in both scenarios are reviewed.</description><subject>Automatic voltage control</subject><subject>back to back</subject><subject>Coils (windings)</subject><subject>Conversion</subject><subject>DFIG</subject><subject>Distortion</subject><subject>Generators</subject><subject>Harmonic analysis</subject><subject>Harmonic distortion</subject><subject>Harmonics</subject><subject>Power system harmonics</subject><subject>Pulsation</subject><subject>Rotors</subject><subject>WECS</subject><subject>Wind energy</subject><issn>1548-0992</issn><issn>1548-0992</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2016</creationdate><recordtype>article</recordtype><recordid>eNpdkM9LwzAYhoMoOKd3wUvAi5fOpGmTxtvofgkDQeY5pO1XyOiSmbSK_70ZmyKSQ17I8-b7eBC6pWRCKZGPm_V0khLKJyIrWE7JGRrRPCsSImV6_idfoqsQtoSwghdshOYr7XfOmhrPTOid742zATuLl940uHTWQt1Dg2duqDrAixiXYMHryD7hKX6FDwOf1-ii1V2Am9M9Rm-L-aZcJeuX5XM5XSd1mmd9InPNpRQZ56zNKYe2SgmwWrRCcg1Ec161ja5Fk5GsEoLFQ6VgaSoLEqspG6OH4797794HCL3amVBD12kLbgiKFnFOISMe0ft_6NYN3sbtFBWSMZHLKGCMyJGqvQvBQ6v23uy0_1KUqINXFb2qg1d18hord8eKAYBf_Of1Gxt3cNs</recordid><startdate>20160401</startdate><enddate>20160401</enddate><creator>Lopez, A.</creator><creator>Mina, J.</creator><creator>Cardenas, V.</creator><creator>De Leon, S.</creator><creator>Calderon, G.</creator><creator>Alquicira, J. A.</creator><general>IEEE</general><general>The Institute of Electrical and Electronics Engineers, Inc. (IEEE)</general><scope>97E</scope><scope>RIA</scope><scope>RIE</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7SC</scope><scope>7SP</scope><scope>8FD</scope><scope>JQ2</scope><scope>L7M</scope><scope>L~C</scope><scope>L~D</scope><scope>F28</scope><scope>FR3</scope></search><sort><creationdate>20160401</creationdate><title>Harmonic Distortions on Grid Connected Double Fed Generator: A Review</title><author>Lopez, A. ; Mina, J. ; Cardenas, V. ; De Leon, S. ; Calderon, G. ; Alquicira, J. A.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c254t-95a69974663f516efb20e3c7f796ae0a66bfdac7d404b7737371973229805a623</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2016</creationdate><topic>Automatic voltage control</topic><topic>back to back</topic><topic>Coils (windings)</topic><topic>Conversion</topic><topic>DFIG</topic><topic>Distortion</topic><topic>Generators</topic><topic>Harmonic analysis</topic><topic>Harmonic distortion</topic><topic>Harmonics</topic><topic>Power system harmonics</topic><topic>Pulsation</topic><topic>Rotors</topic><topic>WECS</topic><topic>Wind energy</topic><toplevel>online_resources</toplevel><creatorcontrib>Lopez, A.</creatorcontrib><creatorcontrib>Mina, J.</creatorcontrib><creatorcontrib>Cardenas, V.</creatorcontrib><creatorcontrib>De Leon, S.</creatorcontrib><creatorcontrib>Calderon, G.</creatorcontrib><creatorcontrib>Alquicira, J. A.</creatorcontrib><collection>IEEE All-Society Periodicals Package (ASPP) 2005-present</collection><collection>IEEE All-Society Periodicals Package (ASPP) 1998-Present</collection><collection>IEEE/IET Electronic Library (IEL)</collection><collection>CrossRef</collection><collection>Computer and Information Systems Abstracts</collection><collection>Electronics &amp; Communications Abstracts</collection><collection>Technology Research Database</collection><collection>ProQuest Computer Science Collection</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>Computer and Information Systems Abstracts – Academic</collection><collection>Computer and Information Systems Abstracts Professional</collection><collection>ANTE: Abstracts in New Technology &amp; Engineering</collection><collection>Engineering Research Database</collection><jtitle>Revista IEEE América Latina</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Lopez, A.</au><au>Mina, J.</au><au>Cardenas, V.</au><au>De Leon, S.</au><au>Calderon, G.</au><au>Alquicira, J. A.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Harmonic Distortions on Grid Connected Double Fed Generator: A Review</atitle><jtitle>Revista IEEE América Latina</jtitle><stitle>T-LA</stitle><date>2016-04-01</date><risdate>2016</risdate><volume>14</volume><issue>4</issue><spage>1745</spage><epage>1751</epage><pages>1745-1751</pages><issn>1548-0992</issn><eissn>1548-0992</eissn><abstract>There are a number of distortions that affect the correct operation of a wind energy conversion system, among them one of the most significant is the presence of harmonics, which can lead to power or torque pulsations, overheating and increased losses in the stator windings, low power factor, etc. According to the literature, the harmonic sources in a wind energy conversion system can be classified from the grid and harmonics produced in the wind energy conversion system. This paper presents a review about the solutions for harmonic distortions on grid connected double fed generator based in a back to back converter. The techniques employed to reduce the harmonic contamination to the grid in both scenarios are reviewed.</abstract><cop>Los Alamitos</cop><pub>IEEE</pub><doi>10.1109/TLA.2016.7483510</doi><tpages>7</tpages></addata></record>
fulltext fulltext
identifier ISSN: 1548-0992
ispartof Revista IEEE América Latina, 2016-04, Vol.14 (4), p.1745-1751
issn 1548-0992
1548-0992
language eng
recordid cdi_crossref_primary_10_1109_TLA_2016_7483510
source IEEE Xplore (Online service)
subjects Automatic voltage control
back to back
Coils (windings)
Conversion
DFIG
Distortion
Generators
Harmonic analysis
Harmonic distortion
Harmonics
Power system harmonics
Pulsation
Rotors
WECS
Wind energy
title Harmonic Distortions on Grid Connected Double Fed Generator: A Review
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-26T11%3A18%3A47IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Harmonic%20Distortions%20on%20Grid%20Connected%20Double%20Fed%20Generator:%20A%20Review&rft.jtitle=Revista%20IEEE%20Am%C3%A9rica%20Latina&rft.au=Lopez,%20A.&rft.date=2016-04-01&rft.volume=14&rft.issue=4&rft.spage=1745&rft.epage=1751&rft.pages=1745-1751&rft.issn=1548-0992&rft.eissn=1548-0992&rft_id=info:doi/10.1109/TLA.2016.7483510&rft_dat=%3Cproquest_cross%3E1825489980%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c254t-95a69974663f516efb20e3c7f796ae0a66bfdac7d404b7737371973229805a623%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=1793375968&rft_id=info:pmid/&rft_ieee_id=7483510&rfr_iscdi=true