Loading…
Parameter Determination of PMSM Using Coupled Electromagnetic and Thermal Model Incorporating Current Harmonics
With advent in permanent magnet synchronous machine (PMSM) structure and inverter topologies, accurate parameter determination is of significance for high-performance control, analysis, and making critical decisions on inter-dependent design parameter variations for machine optimization. However, th...
Saved in:
Published in: | IEEE transactions on magnetics 2018-11, Vol.54 (11), p.1-5 |
---|---|
Main Authors: | , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c293t-1defc34371a369f82f544b103cc326c92997bf74685f0e873884bc7923e6ee8a3 |
---|---|
cites | cdi_FETCH-LOGICAL-c293t-1defc34371a369f82f544b103cc326c92997bf74685f0e873884bc7923e6ee8a3 |
container_end_page | 5 |
container_issue | 11 |
container_start_page | 1 |
container_title | IEEE transactions on magnetics |
container_volume | 54 |
creator | Mukundan, Shruthi Dhulipati, Himavarsha Tjong, Jimi Kar, Narayan C. |
description | With advent in permanent magnet synchronous machine (PMSM) structure and inverter topologies, accurate parameter determination is of significance for high-performance control, analysis, and making critical decisions on inter-dependent design parameter variations for machine optimization. However, the machine parameters, including permanent magnet (PM) flux linkage and dq -axis inductances, vary during operation with machine nonlinearities such as magnetic saturation, temperature rise, and the introduction of spatial- and time-harmonic contents contributing toward inaccuracies during machine parameter determination. While classical dq -axis modeling fails to accommodate non-sinusoidal winding distributions and the effects of temperature rise, finite-element analysis (FEA) is computationally expensive and coupling of electromagnetic and thermal analysis including current harmonics becomes complex. Therefore, in this paper, a novel magnetic equivalent circuit model incorporating the effects of temperature rise and current harmonics has been developed for parameter determination of PMSMs. A lumped thermal model is implemented to determine the temperatures at each point of the machine. The proposed coupled electromagnetic and thermal model has been validated for various operating conditions of a fractional-slot distributed wound laboratory PMSM with FEA and experimental investigations. |
doi_str_mv | 10.1109/TMAG.2018.2837087 |
format | article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1109_TMAG_2018_2837087</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>8479301</ieee_id><sourcerecordid>2121939476</sourcerecordid><originalsourceid>FETCH-LOGICAL-c293t-1defc34371a369f82f544b103cc326c92997bf74685f0e873884bc7923e6ee8a3</originalsourceid><addsrcrecordid>eNo9kE1Lw0AQhhdRsFZ_gHhZ8Jy6X83uHkutbaHBgu05bDeTmpLsxt304L83ocXLDMO8zww8CD1TMqGU6LddNltOGKFqwhSXRMkbNKJa0ISQVN-iEelXiRapuEcPMZ76UUwpGSG_NcE00EHA70NtKme6yjvsS7zNvjK8j5U74rk_tzUUeFGD7YJvzNFBV1lsXIF33z1mapz5Amq8dtaH1of-ysCdQwDX4ZUJjXeVjY_orjR1hKdrH6P9x2I3XyWbz-V6PtsklmneJbSA0nLBJTU81aVi5VSIAyXcWs5Sq5nW8lBKkappSUBJrpQ4WKkZhxRAGT5Gr5e7bfA_Z4hdfvLn4PqXOaOMaq6FTPsUvaRs8DEGKPM2VI0Jvzkl-eA1H7zmg9f86rVnXi5MBQD_eSWk5oTyP6ySdIA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2121939476</pqid></control><display><type>article</type><title>Parameter Determination of PMSM Using Coupled Electromagnetic and Thermal Model Incorporating Current Harmonics</title><source>IEEE Electronic Library (IEL) Journals</source><creator>Mukundan, Shruthi ; Dhulipati, Himavarsha ; Tjong, Jimi ; Kar, Narayan C.</creator><creatorcontrib>Mukundan, Shruthi ; Dhulipati, Himavarsha ; Tjong, Jimi ; Kar, Narayan C.</creatorcontrib><description>With advent in permanent magnet synchronous machine (PMSM) structure and inverter topologies, accurate parameter determination is of significance for high-performance control, analysis, and making critical decisions on inter-dependent design parameter variations for machine optimization. However, the machine parameters, including permanent magnet (PM) flux linkage and dq -axis inductances, vary during operation with machine nonlinearities such as magnetic saturation, temperature rise, and the introduction of spatial- and time-harmonic contents contributing toward inaccuracies during machine parameter determination. While classical dq -axis modeling fails to accommodate non-sinusoidal winding distributions and the effects of temperature rise, finite-element analysis (FEA) is computationally expensive and coupling of electromagnetic and thermal analysis including current harmonics becomes complex. Therefore, in this paper, a novel magnetic equivalent circuit model incorporating the effects of temperature rise and current harmonics has been developed for parameter determination of PMSMs. A lumped thermal model is implemented to determine the temperatures at each point of the machine. The proposed coupled electromagnetic and thermal model has been validated for various operating conditions of a fractional-slot distributed wound laboratory PMSM with FEA and experimental investigations.</description><identifier>ISSN: 0018-9464</identifier><identifier>EISSN: 1941-0069</identifier><identifier>DOI: 10.1109/TMAG.2018.2837087</identifier><identifier>CODEN: IEMGAQ</identifier><language>eng</language><publisher>New York: IEEE</publisher><subject>Circuits ; Computational modeling ; Decision analysis ; Design optimization ; Design parameters ; Electromagnetic modeling ; Equivalent circuits ; Finite element method ; finite-element analysis (FEA) ; Harmonic analysis ; Harmonics ; inductance ; magnetic circuits ; Magnetic saturation ; Magnetism ; Mathematical models ; parameter determination ; permanent magnet machines ; Permanent magnets ; Saturation magnetization ; Stators ; Synchronous machines ; Temperature ; Temperature effects ; Thermal analysis ; Windings</subject><ispartof>IEEE transactions on magnetics, 2018-11, Vol.54 (11), p.1-5</ispartof><rights>Copyright The Institute of Electrical and Electronics Engineers, Inc. (IEEE) 2018</rights><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c293t-1defc34371a369f82f544b103cc326c92997bf74685f0e873884bc7923e6ee8a3</citedby><cites>FETCH-LOGICAL-c293t-1defc34371a369f82f544b103cc326c92997bf74685f0e873884bc7923e6ee8a3</cites><orcidid>0000-0003-3796-5503 ; 0000-0002-5086-3627</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/8479301$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>314,780,784,27924,27925,54796</link.rule.ids></links><search><creatorcontrib>Mukundan, Shruthi</creatorcontrib><creatorcontrib>Dhulipati, Himavarsha</creatorcontrib><creatorcontrib>Tjong, Jimi</creatorcontrib><creatorcontrib>Kar, Narayan C.</creatorcontrib><title>Parameter Determination of PMSM Using Coupled Electromagnetic and Thermal Model Incorporating Current Harmonics</title><title>IEEE transactions on magnetics</title><addtitle>TMAG</addtitle><description>With advent in permanent magnet synchronous machine (PMSM) structure and inverter topologies, accurate parameter determination is of significance for high-performance control, analysis, and making critical decisions on inter-dependent design parameter variations for machine optimization. However, the machine parameters, including permanent magnet (PM) flux linkage and dq -axis inductances, vary during operation with machine nonlinearities such as magnetic saturation, temperature rise, and the introduction of spatial- and time-harmonic contents contributing toward inaccuracies during machine parameter determination. While classical dq -axis modeling fails to accommodate non-sinusoidal winding distributions and the effects of temperature rise, finite-element analysis (FEA) is computationally expensive and coupling of electromagnetic and thermal analysis including current harmonics becomes complex. Therefore, in this paper, a novel magnetic equivalent circuit model incorporating the effects of temperature rise and current harmonics has been developed for parameter determination of PMSMs. A lumped thermal model is implemented to determine the temperatures at each point of the machine. The proposed coupled electromagnetic and thermal model has been validated for various operating conditions of a fractional-slot distributed wound laboratory PMSM with FEA and experimental investigations.</description><subject>Circuits</subject><subject>Computational modeling</subject><subject>Decision analysis</subject><subject>Design optimization</subject><subject>Design parameters</subject><subject>Electromagnetic modeling</subject><subject>Equivalent circuits</subject><subject>Finite element method</subject><subject>finite-element analysis (FEA)</subject><subject>Harmonic analysis</subject><subject>Harmonics</subject><subject>inductance</subject><subject>magnetic circuits</subject><subject>Magnetic saturation</subject><subject>Magnetism</subject><subject>Mathematical models</subject><subject>parameter determination</subject><subject>permanent magnet machines</subject><subject>Permanent magnets</subject><subject>Saturation magnetization</subject><subject>Stators</subject><subject>Synchronous machines</subject><subject>Temperature</subject><subject>Temperature effects</subject><subject>Thermal analysis</subject><subject>Windings</subject><issn>0018-9464</issn><issn>1941-0069</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2018</creationdate><recordtype>article</recordtype><recordid>eNo9kE1Lw0AQhhdRsFZ_gHhZ8Jy6X83uHkutbaHBgu05bDeTmpLsxt304L83ocXLDMO8zww8CD1TMqGU6LddNltOGKFqwhSXRMkbNKJa0ISQVN-iEelXiRapuEcPMZ76UUwpGSG_NcE00EHA70NtKme6yjvsS7zNvjK8j5U74rk_tzUUeFGD7YJvzNFBV1lsXIF33z1mapz5Amq8dtaH1of-ysCdQwDX4ZUJjXeVjY_orjR1hKdrH6P9x2I3XyWbz-V6PtsklmneJbSA0nLBJTU81aVi5VSIAyXcWs5Sq5nW8lBKkappSUBJrpQ4WKkZhxRAGT5Gr5e7bfA_Z4hdfvLn4PqXOaOMaq6FTPsUvaRs8DEGKPM2VI0Jvzkl-eA1H7zmg9f86rVnXi5MBQD_eSWk5oTyP6ySdIA</recordid><startdate>20181101</startdate><enddate>20181101</enddate><creator>Mukundan, Shruthi</creator><creator>Dhulipati, Himavarsha</creator><creator>Tjong, Jimi</creator><creator>Kar, Narayan C.</creator><general>IEEE</general><general>The Institute of Electrical and Electronics Engineers, Inc. (IEEE)</general><scope>97E</scope><scope>RIA</scope><scope>RIE</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7SP</scope><scope>7U5</scope><scope>8BQ</scope><scope>8FD</scope><scope>JG9</scope><scope>L7M</scope><orcidid>https://orcid.org/0000-0003-3796-5503</orcidid><orcidid>https://orcid.org/0000-0002-5086-3627</orcidid></search><sort><creationdate>20181101</creationdate><title>Parameter Determination of PMSM Using Coupled Electromagnetic and Thermal Model Incorporating Current Harmonics</title><author>Mukundan, Shruthi ; Dhulipati, Himavarsha ; Tjong, Jimi ; Kar, Narayan C.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c293t-1defc34371a369f82f544b103cc326c92997bf74685f0e873884bc7923e6ee8a3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2018</creationdate><topic>Circuits</topic><topic>Computational modeling</topic><topic>Decision analysis</topic><topic>Design optimization</topic><topic>Design parameters</topic><topic>Electromagnetic modeling</topic><topic>Equivalent circuits</topic><topic>Finite element method</topic><topic>finite-element analysis (FEA)</topic><topic>Harmonic analysis</topic><topic>Harmonics</topic><topic>inductance</topic><topic>magnetic circuits</topic><topic>Magnetic saturation</topic><topic>Magnetism</topic><topic>Mathematical models</topic><topic>parameter determination</topic><topic>permanent magnet machines</topic><topic>Permanent magnets</topic><topic>Saturation magnetization</topic><topic>Stators</topic><topic>Synchronous machines</topic><topic>Temperature</topic><topic>Temperature effects</topic><topic>Thermal analysis</topic><topic>Windings</topic><toplevel>online_resources</toplevel><creatorcontrib>Mukundan, Shruthi</creatorcontrib><creatorcontrib>Dhulipati, Himavarsha</creatorcontrib><creatorcontrib>Tjong, Jimi</creatorcontrib><creatorcontrib>Kar, Narayan C.</creatorcontrib><collection>IEEE All-Society Periodicals Package (ASPP) 2005-present</collection><collection>IEEE All-Society Periodicals Package (ASPP) Online</collection><collection>IEEE/IET Electronic Library</collection><collection>CrossRef</collection><collection>Electronics & Communications Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>Materials Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>IEEE transactions on magnetics</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Mukundan, Shruthi</au><au>Dhulipati, Himavarsha</au><au>Tjong, Jimi</au><au>Kar, Narayan C.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Parameter Determination of PMSM Using Coupled Electromagnetic and Thermal Model Incorporating Current Harmonics</atitle><jtitle>IEEE transactions on magnetics</jtitle><stitle>TMAG</stitle><date>2018-11-01</date><risdate>2018</risdate><volume>54</volume><issue>11</issue><spage>1</spage><epage>5</epage><pages>1-5</pages><issn>0018-9464</issn><eissn>1941-0069</eissn><coden>IEMGAQ</coden><abstract>With advent in permanent magnet synchronous machine (PMSM) structure and inverter topologies, accurate parameter determination is of significance for high-performance control, analysis, and making critical decisions on inter-dependent design parameter variations for machine optimization. However, the machine parameters, including permanent magnet (PM) flux linkage and dq -axis inductances, vary during operation with machine nonlinearities such as magnetic saturation, temperature rise, and the introduction of spatial- and time-harmonic contents contributing toward inaccuracies during machine parameter determination. While classical dq -axis modeling fails to accommodate non-sinusoidal winding distributions and the effects of temperature rise, finite-element analysis (FEA) is computationally expensive and coupling of electromagnetic and thermal analysis including current harmonics becomes complex. Therefore, in this paper, a novel magnetic equivalent circuit model incorporating the effects of temperature rise and current harmonics has been developed for parameter determination of PMSMs. A lumped thermal model is implemented to determine the temperatures at each point of the machine. The proposed coupled electromagnetic and thermal model has been validated for various operating conditions of a fractional-slot distributed wound laboratory PMSM with FEA and experimental investigations.</abstract><cop>New York</cop><pub>IEEE</pub><doi>10.1109/TMAG.2018.2837087</doi><tpages>5</tpages><orcidid>https://orcid.org/0000-0003-3796-5503</orcidid><orcidid>https://orcid.org/0000-0002-5086-3627</orcidid></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0018-9464 |
ispartof | IEEE transactions on magnetics, 2018-11, Vol.54 (11), p.1-5 |
issn | 0018-9464 1941-0069 |
language | eng |
recordid | cdi_crossref_primary_10_1109_TMAG_2018_2837087 |
source | IEEE Electronic Library (IEL) Journals |
subjects | Circuits Computational modeling Decision analysis Design optimization Design parameters Electromagnetic modeling Equivalent circuits Finite element method finite-element analysis (FEA) Harmonic analysis Harmonics inductance magnetic circuits Magnetic saturation Magnetism Mathematical models parameter determination permanent magnet machines Permanent magnets Saturation magnetization Stators Synchronous machines Temperature Temperature effects Thermal analysis Windings |
title | Parameter Determination of PMSM Using Coupled Electromagnetic and Thermal Model Incorporating Current Harmonics |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-07T15%3A30%3A21IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Parameter%20Determination%20of%20PMSM%20Using%20Coupled%20Electromagnetic%20and%20Thermal%20Model%20Incorporating%20Current%20Harmonics&rft.jtitle=IEEE%20transactions%20on%20magnetics&rft.au=Mukundan,%20Shruthi&rft.date=2018-11-01&rft.volume=54&rft.issue=11&rft.spage=1&rft.epage=5&rft.pages=1-5&rft.issn=0018-9464&rft.eissn=1941-0069&rft.coden=IEMGAQ&rft_id=info:doi/10.1109/TMAG.2018.2837087&rft_dat=%3Cproquest_cross%3E2121939476%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c293t-1defc34371a369f82f544b103cc326c92997bf74685f0e873884bc7923e6ee8a3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2121939476&rft_id=info:pmid/&rft_ieee_id=8479301&rfr_iscdi=true |