Loading…

The use of Flourocarbon Gases to Prevent Arc-Over in DC Capacitors

The use of Fr-14 (CF 4 ) and Fr-116 (C 2 F 6 ) to increase the margin arc-over voltage in dry Mylar energy storage capacitors is investigated. It is found that pressurization of capacitors with Fr-14 results in a small increase in arc-over voltage. However, pressurization with Fr-116 results in arco...

Full description

Saved in:
Bibliographic Details
Published in:IEEE transactions on parts, hybrids, and packaging hybrids, and packaging, 1975-06, Vol.11 (2), p.108-110
Main Author: Loescher, D.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:The use of Fr-14 (CF 4 ) and Fr-116 (C 2 F 6 ) to increase the margin arc-over voltage in dry Mylar energy storage capacitors is investigated. It is found that pressurization of capacitors with Fr-14 results in a small increase in arc-over voltage. However, pressurization with Fr-116 results in arcover voltages 1.5 to 2.5 times larger than obtained in air.
ISSN:0361-1000
1558-2469
DOI:10.1109/TPHP.1975.1135046