Loading…
The use of Flourocarbon Gases to Prevent Arc-Over in DC Capacitors
The use of Fr-14 (CF 4 ) and Fr-116 (C 2 F 6 ) to increase the margin arc-over voltage in dry Mylar energy storage capacitors is investigated. It is found that pressurization of capacitors with Fr-14 results in a small increase in arc-over voltage. However, pressurization with Fr-116 results in arco...
Saved in:
Published in: | IEEE transactions on parts, hybrids, and packaging hybrids, and packaging, 1975-06, Vol.11 (2), p.108-110 |
---|---|
Main Author: | |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | The use of Fr-14 (CF 4 ) and Fr-116 (C 2 F 6 ) to increase the margin arc-over voltage in dry Mylar energy storage capacitors is investigated. It is found that pressurization of capacitors with Fr-14 results in a small increase in arc-over voltage. However, pressurization with Fr-116 results in arcover voltages 1.5 to 2.5 times larger than obtained in air. |
---|---|
ISSN: | 0361-1000 1558-2469 |
DOI: | 10.1109/TPHP.1975.1135046 |