Loading…

Optimal Placement of GIC Blocking Devices Considering Equipment Thermal Limits and Power System Operation Constraints

A practical mitigation of the geomagnetic disturbance (GMD) consequences in power systems is not possible without taking into account the equipment thermal limits and operational constraints. This paper presents such limitations, develops the required equations and characteristics, and proposes a ge...

Full description

Saved in:
Bibliographic Details
Published in:IEEE transactions on power delivery 2018-02, Vol.33 (1), p.200-208
Main Authors: Rezaei-Zare, Afshin, Etemadi, Amir H.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c267t-9de6bc0c7d2b8f2b8649cb4a48b255f793e1c6c301aa46ca0454f1eeb3de0733
cites cdi_FETCH-LOGICAL-c267t-9de6bc0c7d2b8f2b8649cb4a48b255f793e1c6c301aa46ca0454f1eeb3de0733
container_end_page 208
container_issue 1
container_start_page 200
container_title IEEE transactions on power delivery
container_volume 33
creator Rezaei-Zare, Afshin
Etemadi, Amir H.
description A practical mitigation of the geomagnetic disturbance (GMD) consequences in power systems is not possible without taking into account the equipment thermal limits and operational constraints. This paper presents such limitations, develops the required equations and characteristics, and proposes a general and comprehensive approach to incorporate these limits in any short-term or long-term geomagnetically induced current (GIC) mitigating solution. As an application, this study formulates the limits in the context of an optimal placement of the GIC blocking devices at the neutral point of the power transformers in the IEEE 118-bus benchmark study system. The proposed optimization problem takes into account synchronous generator real/reactive power capability, acceptable bus voltage magnitudes, transformer hot-spot heating, transmission-line thermal limits, capacitor bank harmonic loading, and synchronous generator rotor heating. This paper shows that the existing standards significantly underestimate the generator rotor heating under the GMD conditions and propose more accurate alternatives. The study results show that considering the equipment thermal limits results in a noticeably different solution when compared with the case of ignoring such limits.
doi_str_mv 10.1109/TPWRD.2017.2711502
format article
fullrecord <record><control><sourceid>crossref_ieee_</sourceid><recordid>TN_cdi_crossref_primary_10_1109_TPWRD_2017_2711502</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>7938414</ieee_id><sourcerecordid>10_1109_TPWRD_2017_2711502</sourcerecordid><originalsourceid>FETCH-LOGICAL-c267t-9de6bc0c7d2b8f2b8649cb4a48b255f793e1c6c301aa46ca0454f1eeb3de0733</originalsourceid><addsrcrecordid>eNo9kNtOwzAMhiMEEmPwAnCTF-hw0rRpL2EbB2nSJqjEZZWmLgR6IslAe3vabeLCsmT58y9_hFwzmDEG6W22eXtZzDgwOeOSsQj4CZmwNJSB4JCckgkkSRQkqZTn5MK5TwAQkMKEbNe9N42q6aZWGhtsPe0q-vg8p_d1p79M-04X-GM0OjrvWmdKtONs-b01_X47-0A78ivTGO-oaku66X7R0ted89jQdY9WedO1e95bZVrvLslZpWqHV8c-JdnDMps_Bav1EH23CjSPpQ_SEuNCg5YlL5JqqFikuhBKJAWPokqmITId6xCYUiLWCkQkKoZYhCWCDMMp4Yez2nbOWazy3g7P2l3OIB-95Xtv-egtP3oboJsDZBDxHxiyEsFE-Ae-1WxU</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Optimal Placement of GIC Blocking Devices Considering Equipment Thermal Limits and Power System Operation Constraints</title><source>IEEE Xplore (Online service)</source><creator>Rezaei-Zare, Afshin ; Etemadi, Amir H.</creator><creatorcontrib>Rezaei-Zare, Afshin ; Etemadi, Amir H.</creatorcontrib><description>A practical mitigation of the geomagnetic disturbance (GMD) consequences in power systems is not possible without taking into account the equipment thermal limits and operational constraints. This paper presents such limitations, develops the required equations and characteristics, and proposes a general and comprehensive approach to incorporate these limits in any short-term or long-term geomagnetically induced current (GIC) mitigating solution. As an application, this study formulates the limits in the context of an optimal placement of the GIC blocking devices at the neutral point of the power transformers in the IEEE 118-bus benchmark study system. The proposed optimization problem takes into account synchronous generator real/reactive power capability, acceptable bus voltage magnitudes, transformer hot-spot heating, transmission-line thermal limits, capacitor bank harmonic loading, and synchronous generator rotor heating. This paper shows that the existing standards significantly underestimate the generator rotor heating under the GMD conditions and propose more accurate alternatives. The study results show that considering the equipment thermal limits results in a noticeably different solution when compared with the case of ignoring such limits.</description><identifier>ISSN: 0885-8977</identifier><identifier>EISSN: 1937-4208</identifier><identifier>DOI: 10.1109/TPWRD.2017.2711502</identifier><identifier>CODEN: ITPDE5</identifier><language>eng</language><publisher>IEEE</publisher><subject>Circuit faults ; Geomagnetic disturbances (GMD) ; geomagnetically induced current (GIC) ; GIC blocking device ; Harmonic analysis ; Power system harmonics ; Power system stability ; Reactive power ; Transformer cores ; transformer saturation ; voltage stability</subject><ispartof>IEEE transactions on power delivery, 2018-02, Vol.33 (1), p.200-208</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c267t-9de6bc0c7d2b8f2b8649cb4a48b255f793e1c6c301aa46ca0454f1eeb3de0733</citedby><cites>FETCH-LOGICAL-c267t-9de6bc0c7d2b8f2b8649cb4a48b255f793e1c6c301aa46ca0454f1eeb3de0733</cites><orcidid>0000-0001-9006-673X</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/7938414$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>314,777,781,27905,27906,54777</link.rule.ids></links><search><creatorcontrib>Rezaei-Zare, Afshin</creatorcontrib><creatorcontrib>Etemadi, Amir H.</creatorcontrib><title>Optimal Placement of GIC Blocking Devices Considering Equipment Thermal Limits and Power System Operation Constraints</title><title>IEEE transactions on power delivery</title><addtitle>TPWRD</addtitle><description>A practical mitigation of the geomagnetic disturbance (GMD) consequences in power systems is not possible without taking into account the equipment thermal limits and operational constraints. This paper presents such limitations, develops the required equations and characteristics, and proposes a general and comprehensive approach to incorporate these limits in any short-term or long-term geomagnetically induced current (GIC) mitigating solution. As an application, this study formulates the limits in the context of an optimal placement of the GIC blocking devices at the neutral point of the power transformers in the IEEE 118-bus benchmark study system. The proposed optimization problem takes into account synchronous generator real/reactive power capability, acceptable bus voltage magnitudes, transformer hot-spot heating, transmission-line thermal limits, capacitor bank harmonic loading, and synchronous generator rotor heating. This paper shows that the existing standards significantly underestimate the generator rotor heating under the GMD conditions and propose more accurate alternatives. The study results show that considering the equipment thermal limits results in a noticeably different solution when compared with the case of ignoring such limits.</description><subject>Circuit faults</subject><subject>Geomagnetic disturbances (GMD)</subject><subject>geomagnetically induced current (GIC)</subject><subject>GIC blocking device</subject><subject>Harmonic analysis</subject><subject>Power system harmonics</subject><subject>Power system stability</subject><subject>Reactive power</subject><subject>Transformer cores</subject><subject>transformer saturation</subject><subject>voltage stability</subject><issn>0885-8977</issn><issn>1937-4208</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2018</creationdate><recordtype>article</recordtype><recordid>eNo9kNtOwzAMhiMEEmPwAnCTF-hw0rRpL2EbB2nSJqjEZZWmLgR6IslAe3vabeLCsmT58y9_hFwzmDEG6W22eXtZzDgwOeOSsQj4CZmwNJSB4JCckgkkSRQkqZTn5MK5TwAQkMKEbNe9N42q6aZWGhtsPe0q-vg8p_d1p79M-04X-GM0OjrvWmdKtONs-b01_X47-0A78ivTGO-oaku66X7R0ted89jQdY9WedO1e95bZVrvLslZpWqHV8c-JdnDMps_Bav1EH23CjSPpQ_SEuNCg5YlL5JqqFikuhBKJAWPokqmITId6xCYUiLWCkQkKoZYhCWCDMMp4Yez2nbOWazy3g7P2l3OIB-95Xtv-egtP3oboJsDZBDxHxiyEsFE-Ae-1WxU</recordid><startdate>201802</startdate><enddate>201802</enddate><creator>Rezaei-Zare, Afshin</creator><creator>Etemadi, Amir H.</creator><general>IEEE</general><scope>97E</scope><scope>RIA</scope><scope>RIE</scope><scope>AAYXX</scope><scope>CITATION</scope><orcidid>https://orcid.org/0000-0001-9006-673X</orcidid></search><sort><creationdate>201802</creationdate><title>Optimal Placement of GIC Blocking Devices Considering Equipment Thermal Limits and Power System Operation Constraints</title><author>Rezaei-Zare, Afshin ; Etemadi, Amir H.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c267t-9de6bc0c7d2b8f2b8649cb4a48b255f793e1c6c301aa46ca0454f1eeb3de0733</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2018</creationdate><topic>Circuit faults</topic><topic>Geomagnetic disturbances (GMD)</topic><topic>geomagnetically induced current (GIC)</topic><topic>GIC blocking device</topic><topic>Harmonic analysis</topic><topic>Power system harmonics</topic><topic>Power system stability</topic><topic>Reactive power</topic><topic>Transformer cores</topic><topic>transformer saturation</topic><topic>voltage stability</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Rezaei-Zare, Afshin</creatorcontrib><creatorcontrib>Etemadi, Amir H.</creatorcontrib><collection>IEEE All-Society Periodicals Package (ASPP) 2005-present</collection><collection>IEEE All-Society Periodicals Package (ASPP) 1998-Present</collection><collection>IEEE Electronic Library (IEL)</collection><collection>CrossRef</collection><jtitle>IEEE transactions on power delivery</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Rezaei-Zare, Afshin</au><au>Etemadi, Amir H.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Optimal Placement of GIC Blocking Devices Considering Equipment Thermal Limits and Power System Operation Constraints</atitle><jtitle>IEEE transactions on power delivery</jtitle><stitle>TPWRD</stitle><date>2018-02</date><risdate>2018</risdate><volume>33</volume><issue>1</issue><spage>200</spage><epage>208</epage><pages>200-208</pages><issn>0885-8977</issn><eissn>1937-4208</eissn><coden>ITPDE5</coden><abstract>A practical mitigation of the geomagnetic disturbance (GMD) consequences in power systems is not possible without taking into account the equipment thermal limits and operational constraints. This paper presents such limitations, develops the required equations and characteristics, and proposes a general and comprehensive approach to incorporate these limits in any short-term or long-term geomagnetically induced current (GIC) mitigating solution. As an application, this study formulates the limits in the context of an optimal placement of the GIC blocking devices at the neutral point of the power transformers in the IEEE 118-bus benchmark study system. The proposed optimization problem takes into account synchronous generator real/reactive power capability, acceptable bus voltage magnitudes, transformer hot-spot heating, transmission-line thermal limits, capacitor bank harmonic loading, and synchronous generator rotor heating. This paper shows that the existing standards significantly underestimate the generator rotor heating under the GMD conditions and propose more accurate alternatives. The study results show that considering the equipment thermal limits results in a noticeably different solution when compared with the case of ignoring such limits.</abstract><pub>IEEE</pub><doi>10.1109/TPWRD.2017.2711502</doi><tpages>9</tpages><orcidid>https://orcid.org/0000-0001-9006-673X</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 0885-8977
ispartof IEEE transactions on power delivery, 2018-02, Vol.33 (1), p.200-208
issn 0885-8977
1937-4208
language eng
recordid cdi_crossref_primary_10_1109_TPWRD_2017_2711502
source IEEE Xplore (Online service)
subjects Circuit faults
Geomagnetic disturbances (GMD)
geomagnetically induced current (GIC)
GIC blocking device
Harmonic analysis
Power system harmonics
Power system stability
Reactive power
Transformer cores
transformer saturation
voltage stability
title Optimal Placement of GIC Blocking Devices Considering Equipment Thermal Limits and Power System Operation Constraints
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-19T19%3A18%3A11IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-crossref_ieee_&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Optimal%20Placement%20of%20GIC%20Blocking%20Devices%20Considering%20Equipment%20Thermal%20Limits%20and%20Power%20System%20Operation%20Constraints&rft.jtitle=IEEE%20transactions%20on%20power%20delivery&rft.au=Rezaei-Zare,%20Afshin&rft.date=2018-02&rft.volume=33&rft.issue=1&rft.spage=200&rft.epage=208&rft.pages=200-208&rft.issn=0885-8977&rft.eissn=1937-4208&rft.coden=ITPDE5&rft_id=info:doi/10.1109/TPWRD.2017.2711502&rft_dat=%3Ccrossref_ieee_%3E10_1109_TPWRD_2017_2711502%3C/crossref_ieee_%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c267t-9de6bc0c7d2b8f2b8649cb4a48b255f793e1c6c301aa46ca0454f1eeb3de0733%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=7938414&rfr_iscdi=true