Loading…
Fluid Excitation Forces Acting on a Square Tube Array
Fluid forces acting on a tube array are important in the assessment of vibration of system components consisting of multiple circular cylinders. This paper presents test results for a square tube array with the pitch-to-diameter ratio of 1.75 subject to turbulent flow. The fluctuating drag and lift...
Saved in:
Published in: | Journal of fluids engineering 1987-12, Vol.109 (4), p.415-423 |
---|---|
Main Authors: | , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Fluid forces acting on a tube array are important in the assessment of vibration of system components consisting of multiple circular cylinders. This paper presents test results for a square tube array with the pitch-to-diameter ratio of 1.75 subject to turbulent flow. The fluctuating drag and lift forces are measured as a function of Reynolds number, incoming flow conditions, and tube location in an array. |
---|---|
ISSN: | 0098-2202 1528-901X |
DOI: | 10.1115/1.3242682 |