Fluid Excitation Forces Acting on a Square Tube Array

Fluid forces acting on a tube array are important in the assessment of vibration of system components consisting of multiple circular cylinders. This paper presents test results for a square tube array with the pitch-to-diameter ratio of 1.75 subject to turbulent flow. The fluctuating drag and lift...

Full description

Saved in:
Bibliographic Details
Published in:Journal of fluids engineering 1987-12, Vol.109 (4), p.415-423
Main Authors: Chen, S. S, Jendrzejczyk, J. A
Format: Article
Language:English
Subjects:
Citations: Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Fluid forces acting on a tube array are important in the assessment of vibration of system components consisting of multiple circular cylinders. This paper presents test results for a square tube array with the pitch-to-diameter ratio of 1.75 subject to turbulent flow. The fluctuating drag and lift forces are measured as a function of Reynolds number, incoming flow conditions, and tube location in an array.