Loading…
Diaphragm-type fiber-optic interferometric acoustic sensor
A diaphragm-type fiber-optic acoustic sensor is developed. In such a sensor, the sound-induced strain is imposed on the fiber on the diaphragm-type sensing element, and can be measured by the use of a Mach-Zehnder interferometer. The diaphragm structure can provide directional response with high sen...
Saved in:
Published in: | Optical Engineering 2003-09, Vol.42 (9), p.2558-2562 |
---|---|
Main Authors: | , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | A diaphragm-type fiber-optic acoustic sensor is developed. In such a sensor, the sound-induced strain is imposed on the fiber on the diaphragm-type sensing element, and can be measured by the use of a Mach-Zehnder interferometer. The diaphragm structure can provide directional response with high sensitivity. The experimental measurement frequency range is from 100 Hz to 5 kHz. The sensitivity and minimum detectable acoustic pressure of the system are
and 82 dB re Pa, respectively. © |
---|---|