Loading…
Partial discharge acoustic emission detector using mandrel-connected fiber Bragg grating sensor
This paper proposes and investigates a partial discharge (PD) detector based on fiber Bragg grating (FBG) sensor and a mandrel to detect and localize PD in power transformers. An identification of PD in the early stages is important, so using high-resolution sensor is considerable. A Teflon hollow m...
Saved in:
Published in: | Optical engineering 2018-07, Vol.57 (7), p.074107-074107 |
---|---|
Main Authors: | , , , , |
Format: | Article |
Language: | English |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | This paper proposes and investigates a partial discharge (PD) detector based on fiber Bragg grating (FBG) sensor and a mandrel to detect and localize PD in power transformers. An identification of PD in the early stages is important, so using high-resolution sensor is considerable. A Teflon hollow mandrel with attached FBG is chosen as the inner transformer PD detector. The design of the sensor in terms of materials, dimensions, and the shape is chosen; it receives signal strength according to the obtained distance and angle. Standard deviation of angle data is |
---|---|
ISSN: | 0091-3286 1560-2303 |
DOI: | 10.1117/1.OE.57.7.074107 |