SU‐GG‐I‐115: Clinical Evaluation of Three Automatic Image Registration Algorithms from Two Commercial Systems

Purpose: Commercial image registration systems are often directly used in clinics to determine treatment setup for patients. It is imperative to assess the accuracy of these commercial systems because of their direct impact of radiation delivery. The purpose of this study is to investigate the accur...

Full description

Saved in:
Bibliographic Details
Published in:Medical Physics 2010-06, Vol.37 (6), p.3128-3128
Main Authors: Gajdos, S, Kolar, M, Xia, P
Format: Article
Language:English
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by
cites
container_end_page 3128
container_issue 6
container_start_page 3128
container_title Medical Physics
container_volume 37
creator Gajdos, S
Kolar, M
Xia, P
description Purpose: Commercial image registration systems are often directly used in clinics to determine treatment setup for patients. It is imperative to assess the accuracy of these commercial systems because of their direct impact of radiation delivery. The purpose of this study is to investigate the accuracy of two commercially available image fusion systems implemented in our clinic. Methods and Materials: A pelvic anthropomorphic phantom was CT‐scanned and the pelvic bone, femoral heads, and sacrum were contoured. The phantom was setup in fifteen different positions and the corresponding MV‐CBCTs were acquired with 8 MU for a 200 arc. Two commercially available image fusion systems (Syngo from Siemens and Mosiaq from Elekta) were used to automatically align the MV‐CBCTs with the planning CT based on a maximizing mutual information (MMI) algorithm. Furthermore, a chamfer algorithm was evaluated for the Mosiaq system. Based on contours of bony structures, manual alignments in Syngo were conducted carefully by an experienced physicist and were used as the benchmark. Results: Compared to the manual alignments, the mean differences in lateral shifts from automatic registrations were 0.7 cm, 0.2 cm, and 0.2 cm for Syngoauto, MosaiqMMI, and MosaiqChamfer, respectively. The mean differences in longitudinal/vertical shifts were 0.5/0.3 cm, 0.0/0.0 cm, and 0.0/−0.1 cm, respectively. The standard deviations for measurements were 0.1 cm. Conclusion: The accuracy of automatic image registration varied from system to system. The Mosaiq system aligned datasets automatically within 2 mm accuracy for both algorithms. Larger deviations were observed in the Syngo system with automatic alignment, indicating that additional manual adjustments were necessary. Conflict of Interest: A contributing author has grant support from Siemens Medical Solutions.
doi_str_mv 10.1118/1.3468148
format article
fullrecord <record><control><sourceid>wiley_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1118_1_3468148</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>MP8148</sourcerecordid><originalsourceid>FETCH-LOGICAL-c1778-57d46e3d1349831263f00514bbd3d2418130d28868835f5feb9c39dbc0f418d93</originalsourceid><addsrcrecordid>eNp9kM9Kw0AQhxdRsFYPvsFeFVJ3sptk460ErYWKYttzSPZPu5Ltym5q6c1H8Bl9EqPpVQ8zAzMfH8wPoUsgIwDgNzCiLOXA-BEaxCyjEYtJfowGhOQsihlJTtFZCK-EkJQmZIDCfPn18TmZdG3aFUByi4vGbIyoGnz3XjXbqjVug53Gi7VXCo-3rbPdTuCprVYKv6iVCa3vqXGzct60axuw9s7ixc7hwlmrvDCdb74PrbLhHJ3oqgnq4jCHaHl_tygeotnTZFqMZ5GALONRkkmWKiqBspxTiFOqCUmA1bWkMmbAgRIZc55yThOdaFXnguayFkR3R5nTIbrqvcK7ELzS5Zs3tvL7Ekj5k1YJ5SGtjo16dmcatf8bLB-fD_x1zwdh2t_n_5F_A8bzeUQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>SU‐GG‐I‐115: Clinical Evaluation of Three Automatic Image Registration Algorithms from Two Commercial Systems</title><source>Wiley:Jisc Collections:Wiley Read and Publish Open Access 2024-2025 (reading list)</source><creator>Gajdos, S ; Kolar, M ; Xia, P</creator><creatorcontrib>Gajdos, S ; Kolar, M ; Xia, P</creatorcontrib><description>Purpose: Commercial image registration systems are often directly used in clinics to determine treatment setup for patients. It is imperative to assess the accuracy of these commercial systems because of their direct impact of radiation delivery. The purpose of this study is to investigate the accuracy of two commercially available image fusion systems implemented in our clinic. Methods and Materials: A pelvic anthropomorphic phantom was CT‐scanned and the pelvic bone, femoral heads, and sacrum were contoured. The phantom was setup in fifteen different positions and the corresponding MV‐CBCTs were acquired with 8 MU for a 200 arc. Two commercially available image fusion systems (Syngo from Siemens and Mosiaq from Elekta) were used to automatically align the MV‐CBCTs with the planning CT based on a maximizing mutual information (MMI) algorithm. Furthermore, a chamfer algorithm was evaluated for the Mosiaq system. Based on contours of bony structures, manual alignments in Syngo were conducted carefully by an experienced physicist and were used as the benchmark. Results: Compared to the manual alignments, the mean differences in lateral shifts from automatic registrations were 0.7 cm, 0.2 cm, and 0.2 cm for Syngoauto, MosaiqMMI, and MosaiqChamfer, respectively. The mean differences in longitudinal/vertical shifts were 0.5/0.3 cm, 0.0/0.0 cm, and 0.0/−0.1 cm, respectively. The standard deviations for measurements were 0.1 cm. Conclusion: The accuracy of automatic image registration varied from system to system. The Mosaiq system aligned datasets automatically within 2 mm accuracy for both algorithms. Larger deviations were observed in the Syngo system with automatic alignment, indicating that additional manual adjustments were necessary. Conflict of Interest: A contributing author has grant support from Siemens Medical Solutions.</description><identifier>ISSN: 0094-2405</identifier><identifier>EISSN: 2473-4209</identifier><identifier>DOI: 10.1118/1.3468148</identifier><identifier>CODEN: MPHYA6</identifier><language>eng</language><publisher>American Association of Physicists in Medicine</publisher><subject>Computed tomography ; Exposure assessment ; Image registration ; Information integration ; Medical imaging ; Physicists ; Radiation treatment ; Therapeutics</subject><ispartof>Medical Physics, 2010-06, Vol.37 (6), p.3128-3128</ispartof><rights>American Association of Physicists in Medicine</rights><rights>2010 American Association of Physicists in Medicine</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>309,310,314,776,780,785,786,23909,23910,25118,27901,27902</link.rule.ids></links><search><creatorcontrib>Gajdos, S</creatorcontrib><creatorcontrib>Kolar, M</creatorcontrib><creatorcontrib>Xia, P</creatorcontrib><title>SU‐GG‐I‐115: Clinical Evaluation of Three Automatic Image Registration Algorithms from Two Commercial Systems</title><title>Medical Physics</title><description>Purpose: Commercial image registration systems are often directly used in clinics to determine treatment setup for patients. It is imperative to assess the accuracy of these commercial systems because of their direct impact of radiation delivery. The purpose of this study is to investigate the accuracy of two commercially available image fusion systems implemented in our clinic. Methods and Materials: A pelvic anthropomorphic phantom was CT‐scanned and the pelvic bone, femoral heads, and sacrum were contoured. The phantom was setup in fifteen different positions and the corresponding MV‐CBCTs were acquired with 8 MU for a 200 arc. Two commercially available image fusion systems (Syngo from Siemens and Mosiaq from Elekta) were used to automatically align the MV‐CBCTs with the planning CT based on a maximizing mutual information (MMI) algorithm. Furthermore, a chamfer algorithm was evaluated for the Mosiaq system. Based on contours of bony structures, manual alignments in Syngo were conducted carefully by an experienced physicist and were used as the benchmark. Results: Compared to the manual alignments, the mean differences in lateral shifts from automatic registrations were 0.7 cm, 0.2 cm, and 0.2 cm for Syngoauto, MosaiqMMI, and MosaiqChamfer, respectively. The mean differences in longitudinal/vertical shifts were 0.5/0.3 cm, 0.0/0.0 cm, and 0.0/−0.1 cm, respectively. The standard deviations for measurements were 0.1 cm. Conclusion: The accuracy of automatic image registration varied from system to system. The Mosaiq system aligned datasets automatically within 2 mm accuracy for both algorithms. Larger deviations were observed in the Syngo system with automatic alignment, indicating that additional manual adjustments were necessary. Conflict of Interest: A contributing author has grant support from Siemens Medical Solutions.</description><subject>Computed tomography</subject><subject>Exposure assessment</subject><subject>Image registration</subject><subject>Information integration</subject><subject>Medical imaging</subject><subject>Physicists</subject><subject>Radiation treatment</subject><subject>Therapeutics</subject><issn>0094-2405</issn><issn>2473-4209</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2010</creationdate><recordtype>article</recordtype><recordid>eNp9kM9Kw0AQhxdRsFYPvsFeFVJ3sptk460ErYWKYttzSPZPu5Ltym5q6c1H8Bl9EqPpVQ8zAzMfH8wPoUsgIwDgNzCiLOXA-BEaxCyjEYtJfowGhOQsihlJTtFZCK-EkJQmZIDCfPn18TmZdG3aFUByi4vGbIyoGnz3XjXbqjVug53Gi7VXCo-3rbPdTuCprVYKv6iVCa3vqXGzct60axuw9s7ixc7hwlmrvDCdb74PrbLhHJ3oqgnq4jCHaHl_tygeotnTZFqMZ5GALONRkkmWKiqBspxTiFOqCUmA1bWkMmbAgRIZc55yThOdaFXnguayFkR3R5nTIbrqvcK7ELzS5Zs3tvL7Ekj5k1YJ5SGtjo16dmcatf8bLB-fD_x1zwdh2t_n_5F_A8bzeUQ</recordid><startdate>201006</startdate><enddate>201006</enddate><creator>Gajdos, S</creator><creator>Kolar, M</creator><creator>Xia, P</creator><general>American Association of Physicists in Medicine</general><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>201006</creationdate><title>SU‐GG‐I‐115: Clinical Evaluation of Three Automatic Image Registration Algorithms from Two Commercial Systems</title><author>Gajdos, S ; Kolar, M ; Xia, P</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c1778-57d46e3d1349831263f00514bbd3d2418130d28868835f5feb9c39dbc0f418d93</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2010</creationdate><topic>Computed tomography</topic><topic>Exposure assessment</topic><topic>Image registration</topic><topic>Information integration</topic><topic>Medical imaging</topic><topic>Physicists</topic><topic>Radiation treatment</topic><topic>Therapeutics</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Gajdos, S</creatorcontrib><creatorcontrib>Kolar, M</creatorcontrib><creatorcontrib>Xia, P</creatorcontrib><collection>CrossRef</collection><jtitle>Medical Physics</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Gajdos, S</au><au>Kolar, M</au><au>Xia, P</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>SU‐GG‐I‐115: Clinical Evaluation of Three Automatic Image Registration Algorithms from Two Commercial Systems</atitle><jtitle>Medical Physics</jtitle><date>2010-06</date><risdate>2010</risdate><volume>37</volume><issue>6</issue><spage>3128</spage><epage>3128</epage><pages>3128-3128</pages><issn>0094-2405</issn><eissn>2473-4209</eissn><coden>MPHYA6</coden><abstract>Purpose: Commercial image registration systems are often directly used in clinics to determine treatment setup for patients. It is imperative to assess the accuracy of these commercial systems because of their direct impact of radiation delivery. The purpose of this study is to investigate the accuracy of two commercially available image fusion systems implemented in our clinic. Methods and Materials: A pelvic anthropomorphic phantom was CT‐scanned and the pelvic bone, femoral heads, and sacrum were contoured. The phantom was setup in fifteen different positions and the corresponding MV‐CBCTs were acquired with 8 MU for a 200 arc. Two commercially available image fusion systems (Syngo from Siemens and Mosiaq from Elekta) were used to automatically align the MV‐CBCTs with the planning CT based on a maximizing mutual information (MMI) algorithm. Furthermore, a chamfer algorithm was evaluated for the Mosiaq system. Based on contours of bony structures, manual alignments in Syngo were conducted carefully by an experienced physicist and were used as the benchmark. Results: Compared to the manual alignments, the mean differences in lateral shifts from automatic registrations were 0.7 cm, 0.2 cm, and 0.2 cm for Syngoauto, MosaiqMMI, and MosaiqChamfer, respectively. The mean differences in longitudinal/vertical shifts were 0.5/0.3 cm, 0.0/0.0 cm, and 0.0/−0.1 cm, respectively. The standard deviations for measurements were 0.1 cm. Conclusion: The accuracy of automatic image registration varied from system to system. The Mosaiq system aligned datasets automatically within 2 mm accuracy for both algorithms. Larger deviations were observed in the Syngo system with automatic alignment, indicating that additional manual adjustments were necessary. Conflict of Interest: A contributing author has grant support from Siemens Medical Solutions.</abstract><pub>American Association of Physicists in Medicine</pub><doi>10.1118/1.3468148</doi><tpages>1</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0094-2405
ispartof Medical Physics, 2010-06, Vol.37 (6), p.3128-3128
issn 0094-2405
2473-4209
language eng
recordid cdi_crossref_primary_10_1118_1_3468148
source Wiley:Jisc Collections:Wiley Read and Publish Open Access 2024-2025 (reading list)
subjects Computed tomography
Exposure assessment
Image registration
Information integration
Medical imaging
Physicists
Radiation treatment
Therapeutics
title SU‐GG‐I‐115: Clinical Evaluation of Three Automatic Image Registration Algorithms from Two Commercial Systems
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-29T03%3A24%3A59IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-wiley_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=SU%E2%80%90GG%E2%80%90I%E2%80%90115:%20Clinical%20Evaluation%20of%20Three%20Automatic%20Image%20Registration%20Algorithms%20from%20Two%20Commercial%20Systems&rft.jtitle=Medical%20Physics&rft.au=Gajdos,%20S&rft.date=2010-06&rft.volume=37&rft.issue=6&rft.spage=3128&rft.epage=3128&rft.pages=3128-3128&rft.issn=0094-2405&rft.eissn=2473-4209&rft.coden=MPHYA6&rft_id=info:doi/10.1118/1.3468148&rft_dat=%3Cwiley_cross%3EMP8148%3C/wiley_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c1778-57d46e3d1349831263f00514bbd3d2418130d28868835f5feb9c39dbc0f418d93%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true