SU‐GG‐T‐338: Accuracy of Superficial Dose Calculation for Breast Cancer Treatments on Tomotherapy

Purpose: To evaluate the effect of breathing motion and setup error on the accuracy of treatment planning surface dose calculation for breast cancer treatments on helical Tomotherapy. Method and Materials: In‐vivo dosimetry with MOSFET detectors was performed on a cohort of patients treated for brea...

Full description

Saved in:
Bibliographic Details
Published in:Medical Physics 2010-06, Vol.37 (6), p.3263-3264
Main Authors: Green, O Pechenaya, Goddu, S, Rodriguez, V, Cates, J, Michaletz‐Lorenz, M, Zoberi, I
Format: Article
Language:English
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by
cites
container_end_page 3264
container_issue 6
container_start_page 3263
container_title Medical Physics
container_volume 37
creator Green, O Pechenaya
Goddu, S
Rodriguez, V
Cates, J
Michaletz‐Lorenz, M
Zoberi, I
description Purpose: To evaluate the effect of breathing motion and setup error on the accuracy of treatment planning surface dose calculation for breast cancer treatments on helical Tomotherapy. Method and Materials: In‐vivo dosimetry with MOSFET detectors was performed on a cohort of patients treated for breast cancer on helical Tomotherapy. The detectors were placed under the 0.5‐cm tissue‐equivalent bolus used for patient treatments. The pre‐treatment MVCT images were used to localize the MOSFET detectors. Tomotherapy's Planned Adaptive software was used to compare the measurements against both the planned surface doses at the locations of the dosimeters as well as the recalculated doses based on the MVCT scan. This allowed for evaluation of the combined impact of breathing and setup error on the surface dose contribution, and the quantification of dosimetric accuracy of the Tomotherapy treatment planning system for breast cancer patients. Results: The differences between dose values at the locations of the dosimeters from the plan and those calculated from the MVCT image were on average within 1% of each other. The average dosimetric differences between measured and calculated doses were 7.8 and 8 percent for the planned and adaptive calculated doses, respectively. Overall, the treatment planning system overestimated the dose at the skin/bolus interface. Conclusion: The treatment planning system was previously shown to overestimate dose at a 5‐mm depth by about 4%. The possible setup error is taken into account by the adaptive software since it recalculates the dose distribution based on the MVCT image associated with the treatment for which the measurement was made. Since the setup error was shown to be within 1%, it is therefore estimated that the dosimetric consequence of breathing motion may be as high as 3%. Conflict of Interest: This work was partially supported by a grant from Tomotherapy, Inc.
doi_str_mv 10.1118/1.3468735
format article
fullrecord <record><control><sourceid>wiley_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1118_1_3468735</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>MP8735</sourcerecordid><originalsourceid>FETCH-LOGICAL-c1775-fa2ad1e1e6b4f843cc80c2ca965c6328b8c2671c20821c0eb81b12f5a23bd68d3</originalsourceid><addsrcrecordid>eNp9kMFOwzAMhiMEEmNw4A1yBakjTtI04zY2GEhDIK07V6mXQFG3TEkn1BuPwDPyJBS2Kxxsy_an__ARcg5sAAD6CgZCKp2J9ID0uMxEIjkbHpIeY0OZcMnSY3IS4xtjTImU9cjLfPH18Tmddi3vSgh9TUeI22Cwpd7R-XZjg6uwMjWd-Gjp2NS4rU1T-TV1PtCbYE1suvMabaB5tzUru24i7f65X_nm1QazaU_JkTN1tGf72SeLu9t8fJ_MnqYP49EsQciyNHGGmyVYsKqUTkuBqBlyNEOVohJclxq5ygA50xyQ2VJDCdylhotyqfRS9MnFLheDjzFYV2xCtTKhLYAVP4YKKPaGOjbZse9Vbdu_weLxec9f7viIVfNr4J_wb-Eedd4</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>SU‐GG‐T‐338: Accuracy of Superficial Dose Calculation for Breast Cancer Treatments on Tomotherapy</title><source>Wiley:Jisc Collections:Wiley Read and Publish Open Access 2024-2025 (reading list)</source><creator>Green, O Pechenaya ; Goddu, S ; Rodriguez, V ; Cates, J ; Michaletz‐Lorenz, M ; Zoberi, I</creator><creatorcontrib>Green, O Pechenaya ; Goddu, S ; Rodriguez, V ; Cates, J ; Michaletz‐Lorenz, M ; Zoberi, I</creatorcontrib><description>Purpose: To evaluate the effect of breathing motion and setup error on the accuracy of treatment planning surface dose calculation for breast cancer treatments on helical Tomotherapy. Method and Materials: In‐vivo dosimetry with MOSFET detectors was performed on a cohort of patients treated for breast cancer on helical Tomotherapy. The detectors were placed under the 0.5‐cm tissue‐equivalent bolus used for patient treatments. The pre‐treatment MVCT images were used to localize the MOSFET detectors. Tomotherapy's Planned Adaptive software was used to compare the measurements against both the planned surface doses at the locations of the dosimeters as well as the recalculated doses based on the MVCT scan. This allowed for evaluation of the combined impact of breathing and setup error on the surface dose contribution, and the quantification of dosimetric accuracy of the Tomotherapy treatment planning system for breast cancer patients. Results: The differences between dose values at the locations of the dosimeters from the plan and those calculated from the MVCT image were on average within 1% of each other. The average dosimetric differences between measured and calculated doses were 7.8 and 8 percent for the planned and adaptive calculated doses, respectively. Overall, the treatment planning system overestimated the dose at the skin/bolus interface. Conclusion: The treatment planning system was previously shown to overestimate dose at a 5‐mm depth by about 4%. The possible setup error is taken into account by the adaptive software since it recalculates the dose distribution based on the MVCT image associated with the treatment for which the measurement was made. Since the setup error was shown to be within 1%, it is therefore estimated that the dosimetric consequence of breathing motion may be as high as 3%. Conflict of Interest: This work was partially supported by a grant from Tomotherapy, Inc.</description><identifier>ISSN: 0094-2405</identifier><identifier>EISSN: 2473-4209</identifier><identifier>DOI: 10.1118/1.3468735</identifier><identifier>CODEN: MPHYA6</identifier><language>eng</language><publisher>American Association of Physicists in Medicine</publisher><subject>Cancer ; Dosimetry ; Image sensors ; Medical imaging ; Medical treatment planning ; MOSFETs ; Skin ; Surface treatments ; Therapeutics</subject><ispartof>Medical Physics, 2010-06, Vol.37 (6), p.3263-3264</ispartof><rights>American Association of Physicists in Medicine</rights><rights>2010 American Association of Physicists in Medicine</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>309,310,314,780,784,789,790,23930,23931,25140,27924,27925</link.rule.ids></links><search><creatorcontrib>Green, O Pechenaya</creatorcontrib><creatorcontrib>Goddu, S</creatorcontrib><creatorcontrib>Rodriguez, V</creatorcontrib><creatorcontrib>Cates, J</creatorcontrib><creatorcontrib>Michaletz‐Lorenz, M</creatorcontrib><creatorcontrib>Zoberi, I</creatorcontrib><title>SU‐GG‐T‐338: Accuracy of Superficial Dose Calculation for Breast Cancer Treatments on Tomotherapy</title><title>Medical Physics</title><description>Purpose: To evaluate the effect of breathing motion and setup error on the accuracy of treatment planning surface dose calculation for breast cancer treatments on helical Tomotherapy. Method and Materials: In‐vivo dosimetry with MOSFET detectors was performed on a cohort of patients treated for breast cancer on helical Tomotherapy. The detectors were placed under the 0.5‐cm tissue‐equivalent bolus used for patient treatments. The pre‐treatment MVCT images were used to localize the MOSFET detectors. Tomotherapy's Planned Adaptive software was used to compare the measurements against both the planned surface doses at the locations of the dosimeters as well as the recalculated doses based on the MVCT scan. This allowed for evaluation of the combined impact of breathing and setup error on the surface dose contribution, and the quantification of dosimetric accuracy of the Tomotherapy treatment planning system for breast cancer patients. Results: The differences between dose values at the locations of the dosimeters from the plan and those calculated from the MVCT image were on average within 1% of each other. The average dosimetric differences between measured and calculated doses were 7.8 and 8 percent for the planned and adaptive calculated doses, respectively. Overall, the treatment planning system overestimated the dose at the skin/bolus interface. Conclusion: The treatment planning system was previously shown to overestimate dose at a 5‐mm depth by about 4%. The possible setup error is taken into account by the adaptive software since it recalculates the dose distribution based on the MVCT image associated with the treatment for which the measurement was made. Since the setup error was shown to be within 1%, it is therefore estimated that the dosimetric consequence of breathing motion may be as high as 3%. Conflict of Interest: This work was partially supported by a grant from Tomotherapy, Inc.</description><subject>Cancer</subject><subject>Dosimetry</subject><subject>Image sensors</subject><subject>Medical imaging</subject><subject>Medical treatment planning</subject><subject>MOSFETs</subject><subject>Skin</subject><subject>Surface treatments</subject><subject>Therapeutics</subject><issn>0094-2405</issn><issn>2473-4209</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2010</creationdate><recordtype>article</recordtype><recordid>eNp9kMFOwzAMhiMEEmNw4A1yBakjTtI04zY2GEhDIK07V6mXQFG3TEkn1BuPwDPyJBS2Kxxsy_an__ARcg5sAAD6CgZCKp2J9ID0uMxEIjkbHpIeY0OZcMnSY3IS4xtjTImU9cjLfPH18Tmddi3vSgh9TUeI22Cwpd7R-XZjg6uwMjWd-Gjp2NS4rU1T-TV1PtCbYE1suvMabaB5tzUru24i7f65X_nm1QazaU_JkTN1tGf72SeLu9t8fJ_MnqYP49EsQciyNHGGmyVYsKqUTkuBqBlyNEOVohJclxq5ygA50xyQ2VJDCdylhotyqfRS9MnFLheDjzFYV2xCtTKhLYAVP4YKKPaGOjbZse9Vbdu_weLxec9f7viIVfNr4J_wb-Eedd4</recordid><startdate>201006</startdate><enddate>201006</enddate><creator>Green, O Pechenaya</creator><creator>Goddu, S</creator><creator>Rodriguez, V</creator><creator>Cates, J</creator><creator>Michaletz‐Lorenz, M</creator><creator>Zoberi, I</creator><general>American Association of Physicists in Medicine</general><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>201006</creationdate><title>SU‐GG‐T‐338: Accuracy of Superficial Dose Calculation for Breast Cancer Treatments on Tomotherapy</title><author>Green, O Pechenaya ; Goddu, S ; Rodriguez, V ; Cates, J ; Michaletz‐Lorenz, M ; Zoberi, I</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c1775-fa2ad1e1e6b4f843cc80c2ca965c6328b8c2671c20821c0eb81b12f5a23bd68d3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2010</creationdate><topic>Cancer</topic><topic>Dosimetry</topic><topic>Image sensors</topic><topic>Medical imaging</topic><topic>Medical treatment planning</topic><topic>MOSFETs</topic><topic>Skin</topic><topic>Surface treatments</topic><topic>Therapeutics</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Green, O Pechenaya</creatorcontrib><creatorcontrib>Goddu, S</creatorcontrib><creatorcontrib>Rodriguez, V</creatorcontrib><creatorcontrib>Cates, J</creatorcontrib><creatorcontrib>Michaletz‐Lorenz, M</creatorcontrib><creatorcontrib>Zoberi, I</creatorcontrib><collection>CrossRef</collection><jtitle>Medical Physics</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Green, O Pechenaya</au><au>Goddu, S</au><au>Rodriguez, V</au><au>Cates, J</au><au>Michaletz‐Lorenz, M</au><au>Zoberi, I</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>SU‐GG‐T‐338: Accuracy of Superficial Dose Calculation for Breast Cancer Treatments on Tomotherapy</atitle><jtitle>Medical Physics</jtitle><date>2010-06</date><risdate>2010</risdate><volume>37</volume><issue>6</issue><spage>3263</spage><epage>3264</epage><pages>3263-3264</pages><issn>0094-2405</issn><eissn>2473-4209</eissn><coden>MPHYA6</coden><abstract>Purpose: To evaluate the effect of breathing motion and setup error on the accuracy of treatment planning surface dose calculation for breast cancer treatments on helical Tomotherapy. Method and Materials: In‐vivo dosimetry with MOSFET detectors was performed on a cohort of patients treated for breast cancer on helical Tomotherapy. The detectors were placed under the 0.5‐cm tissue‐equivalent bolus used for patient treatments. The pre‐treatment MVCT images were used to localize the MOSFET detectors. Tomotherapy's Planned Adaptive software was used to compare the measurements against both the planned surface doses at the locations of the dosimeters as well as the recalculated doses based on the MVCT scan. This allowed for evaluation of the combined impact of breathing and setup error on the surface dose contribution, and the quantification of dosimetric accuracy of the Tomotherapy treatment planning system for breast cancer patients. Results: The differences between dose values at the locations of the dosimeters from the plan and those calculated from the MVCT image were on average within 1% of each other. The average dosimetric differences between measured and calculated doses were 7.8 and 8 percent for the planned and adaptive calculated doses, respectively. Overall, the treatment planning system overestimated the dose at the skin/bolus interface. Conclusion: The treatment planning system was previously shown to overestimate dose at a 5‐mm depth by about 4%. The possible setup error is taken into account by the adaptive software since it recalculates the dose distribution based on the MVCT image associated with the treatment for which the measurement was made. Since the setup error was shown to be within 1%, it is therefore estimated that the dosimetric consequence of breathing motion may be as high as 3%. Conflict of Interest: This work was partially supported by a grant from Tomotherapy, Inc.</abstract><pub>American Association of Physicists in Medicine</pub><doi>10.1118/1.3468735</doi><tpages>2</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0094-2405
ispartof Medical Physics, 2010-06, Vol.37 (6), p.3263-3264
issn 0094-2405
2473-4209
language eng
recordid cdi_crossref_primary_10_1118_1_3468735
source Wiley:Jisc Collections:Wiley Read and Publish Open Access 2024-2025 (reading list)
subjects Cancer
Dosimetry
Image sensors
Medical imaging
Medical treatment planning
MOSFETs
Skin
Surface treatments
Therapeutics
title SU‐GG‐T‐338: Accuracy of Superficial Dose Calculation for Breast Cancer Treatments on Tomotherapy
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-28T01%3A07%3A38IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-wiley_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=SU%E2%80%90GG%E2%80%90T%E2%80%90338:%20Accuracy%20of%20Superficial%20Dose%20Calculation%20for%20Breast%20Cancer%20Treatments%20on%20Tomotherapy&rft.jtitle=Medical%20Physics&rft.au=Green,%20O%20Pechenaya&rft.date=2010-06&rft.volume=37&rft.issue=6&rft.spage=3263&rft.epage=3264&rft.pages=3263-3264&rft.issn=0094-2405&rft.eissn=2473-4209&rft.coden=MPHYA6&rft_id=info:doi/10.1118/1.3468735&rft_dat=%3Cwiley_cross%3EMP8735%3C/wiley_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c1775-fa2ad1e1e6b4f843cc80c2ca965c6328b8c2671c20821c0eb81b12f5a23bd68d3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true