SU‐D‐110‐06: Delineation of Target Volume Based on FDG PET‐CT Images and Its Effect on Tumor and Normal Tissue Doses
Purpose: To evaluate the effect of FDG PET‐CT imaging on target volume definition, inter and intra observer perceptions, and on tumor and normal tissue doses. Methods: The positron emission tomography with fluorine‐18‐ fluorodeoxyglucose (18F‐FDG) radiopharmaceutical and computed tomography (CT) com...
Saved in:
Published in: | Medical Physics 2011-06, Vol.38 (6), p.3388-3388 |
---|---|
Main Authors: | , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | |
---|---|
cites | |
container_end_page | 3388 |
container_issue | 6 |
container_start_page | 3388 |
container_title | Medical Physics |
container_volume | 38 |
creator | De La Fuente Herman, T Ortega, H Thompson, S Herman, T Ahmad, S |
description | Purpose: To evaluate the effect of FDG PET‐CT imaging on target volume definition, inter and intra observer perceptions, and on tumor and normal tissue doses. Methods: The positron emission tomography with fluorine‐18‐ fluorodeoxyglucose (18F‐FDG) radiopharmaceutical and computed tomography (CT) combined provide structural and functional information for the definition of tumor and radio‐resistant regions that can be treated to high doses. This study uses data from twenty patients who had CT and PET imaging for treatment plan preparation. Treatment plans used non‐opposing co‐planar beams of four to seven fields. The prescribed dose was 70.2 Gy in 39 fractions. Physicians H and T independently delineated tumor volumes on CT and PET‐CT images and treatment plans were generated. Doses to CT contoured structures were obtained from plans that were originally planned based on contoured PET‐CT fused images. Tumor volumes of PET‐ CT and CT were compared by an index of agreement (IA). The intra and inter observer variations on tumor delineation, mean, minimum and maximum tumor doses, and percent differences in uninvolved lung doses were compared. Results: The mean intra observer IA value was approximately 0.50 for both physicians. The mean inter observer IA value was 0.45 and 0.52 for CT and fused PET‐CT tumor outlining respectively. The percent differences in average minimum and mean tumor doses for PET‐CT and CT plans were 60.1% and 8.1% respectively for physician H, and 78.4% and 11.7% respectively for physician T. The uninvolved lung mean dose variations for PET‐CT and CT plans were 5.6% and 1.9% for physicians H and T respectively, and between both physicians the differences were 9.6% and 12.7% for PET‐CT and CT plans respectively. Conclusions: The volumes created on PET‐CT images by two experienced physicians were greatly different compared to volumes created on CT only, resulting in extreme differences in calculated doses. |
doi_str_mv | 10.1118/1.3611542 |
format | article |
fullrecord | <record><control><sourceid>wiley_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1118_1_3611542</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>MP1542</sourcerecordid><originalsourceid>FETCH-LOGICAL-c1772-e1c0febdeaccef75891d05f32e626ddab20ec64b9da178317100438d798f42d3</originalsourceid><addsrcrecordid>eNp9kM1Kw0AQxxdRsFYPvsFeFVJnNpsvb9q0tVC1YPQatruzEkkayaZIwYOP4DP6JKYfVz3MDMz85n_4MXaOMEDE-AoHfogYSHHAekJGvicFJIesB5BIT0gIjtmJc28AEPoB9Njn0_PP13faFSJ0HcJrnlJZLEm1Rb3kteWZal6p5S91uaqI3ypHhneXcTrh81HW_QwzPq3UKzmuloZPW8dH1pJuN1S2qupmu3-om0qVPCucWxFPa0fulB1ZVTo6288-y8ajbHjnzR4n0-HNzNMYRcIj1GBpYUhpTTYK4gQNBNYXFIrQGLUQQDqUi8QojGIfIwSQfmyiJLZSGL_PLnaxuqmda8jm701RqWadI-Qbaznme2sd6-3Yj6Kk9d9gfj_f85c73umi3Sr7J_wXKDh7hQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>SU‐D‐110‐06: Delineation of Target Volume Based on FDG PET‐CT Images and Its Effect on Tumor and Normal Tissue Doses</title><source>Wiley</source><creator>De La Fuente Herman, T ; Ortega, H ; Thompson, S ; Herman, T ; Ahmad, S</creator><creatorcontrib>De La Fuente Herman, T ; Ortega, H ; Thompson, S ; Herman, T ; Ahmad, S</creatorcontrib><description>Purpose: To evaluate the effect of FDG PET‐CT imaging on target volume definition, inter and intra observer perceptions, and on tumor and normal tissue doses. Methods: The positron emission tomography with fluorine‐18‐ fluorodeoxyglucose (18F‐FDG) radiopharmaceutical and computed tomography (CT) combined provide structural and functional information for the definition of tumor and radio‐resistant regions that can be treated to high doses. This study uses data from twenty patients who had CT and PET imaging for treatment plan preparation. Treatment plans used non‐opposing co‐planar beams of four to seven fields. The prescribed dose was 70.2 Gy in 39 fractions. Physicians H and T independently delineated tumor volumes on CT and PET‐CT images and treatment plans were generated. Doses to CT contoured structures were obtained from plans that were originally planned based on contoured PET‐CT fused images. Tumor volumes of PET‐ CT and CT were compared by an index of agreement (IA). The intra and inter observer variations on tumor delineation, mean, minimum and maximum tumor doses, and percent differences in uninvolved lung doses were compared. Results: The mean intra observer IA value was approximately 0.50 for both physicians. The mean inter observer IA value was 0.45 and 0.52 for CT and fused PET‐CT tumor outlining respectively. The percent differences in average minimum and mean tumor doses for PET‐CT and CT plans were 60.1% and 8.1% respectively for physician H, and 78.4% and 11.7% respectively for physician T. The uninvolved lung mean dose variations for PET‐CT and CT plans were 5.6% and 1.9% for physicians H and T respectively, and between both physicians the differences were 9.6% and 12.7% for PET‐CT and CT plans respectively. Conclusions: The volumes created on PET‐CT images by two experienced physicians were greatly different compared to volumes created on CT only, resulting in extreme differences in calculated doses.</description><identifier>ISSN: 0094-2405</identifier><identifier>EISSN: 2473-4209</identifier><identifier>DOI: 10.1118/1.3611542</identifier><identifier>CODEN: MPHYA6</identifier><language>eng</language><publisher>American Association of Physicists in Medicine</publisher><subject>Cancer ; Computed tomography ; Lungs ; Medical imaging ; Positron emission tomography ; Radiopharmaceuticals ; Tissues</subject><ispartof>Medical Physics, 2011-06, Vol.38 (6), p.3388-3388</ispartof><rights>American Association of Physicists in Medicine</rights><rights>2011 American Association of Physicists in Medicine</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>309,310,314,780,784,789,790,23930,23931,25140,27924,27925</link.rule.ids></links><search><creatorcontrib>De La Fuente Herman, T</creatorcontrib><creatorcontrib>Ortega, H</creatorcontrib><creatorcontrib>Thompson, S</creatorcontrib><creatorcontrib>Herman, T</creatorcontrib><creatorcontrib>Ahmad, S</creatorcontrib><title>SU‐D‐110‐06: Delineation of Target Volume Based on FDG PET‐CT Images and Its Effect on Tumor and Normal Tissue Doses</title><title>Medical Physics</title><description>Purpose: To evaluate the effect of FDG PET‐CT imaging on target volume definition, inter and intra observer perceptions, and on tumor and normal tissue doses. Methods: The positron emission tomography with fluorine‐18‐ fluorodeoxyglucose (18F‐FDG) radiopharmaceutical and computed tomography (CT) combined provide structural and functional information for the definition of tumor and radio‐resistant regions that can be treated to high doses. This study uses data from twenty patients who had CT and PET imaging for treatment plan preparation. Treatment plans used non‐opposing co‐planar beams of four to seven fields. The prescribed dose was 70.2 Gy in 39 fractions. Physicians H and T independently delineated tumor volumes on CT and PET‐CT images and treatment plans were generated. Doses to CT contoured structures were obtained from plans that were originally planned based on contoured PET‐CT fused images. Tumor volumes of PET‐ CT and CT were compared by an index of agreement (IA). The intra and inter observer variations on tumor delineation, mean, minimum and maximum tumor doses, and percent differences in uninvolved lung doses were compared. Results: The mean intra observer IA value was approximately 0.50 for both physicians. The mean inter observer IA value was 0.45 and 0.52 for CT and fused PET‐CT tumor outlining respectively. The percent differences in average minimum and mean tumor doses for PET‐CT and CT plans were 60.1% and 8.1% respectively for physician H, and 78.4% and 11.7% respectively for physician T. The uninvolved lung mean dose variations for PET‐CT and CT plans were 5.6% and 1.9% for physicians H and T respectively, and between both physicians the differences were 9.6% and 12.7% for PET‐CT and CT plans respectively. Conclusions: The volumes created on PET‐CT images by two experienced physicians were greatly different compared to volumes created on CT only, resulting in extreme differences in calculated doses.</description><subject>Cancer</subject><subject>Computed tomography</subject><subject>Lungs</subject><subject>Medical imaging</subject><subject>Positron emission tomography</subject><subject>Radiopharmaceuticals</subject><subject>Tissues</subject><issn>0094-2405</issn><issn>2473-4209</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2011</creationdate><recordtype>article</recordtype><recordid>eNp9kM1Kw0AQxxdRsFYPvsFeFVJnNpsvb9q0tVC1YPQatruzEkkayaZIwYOP4DP6JKYfVz3MDMz85n_4MXaOMEDE-AoHfogYSHHAekJGvicFJIesB5BIT0gIjtmJc28AEPoB9Njn0_PP13faFSJ0HcJrnlJZLEm1Rb3kteWZal6p5S91uaqI3ypHhneXcTrh81HW_QwzPq3UKzmuloZPW8dH1pJuN1S2qupmu3-om0qVPCucWxFPa0fulB1ZVTo6288-y8ajbHjnzR4n0-HNzNMYRcIj1GBpYUhpTTYK4gQNBNYXFIrQGLUQQDqUi8QojGIfIwSQfmyiJLZSGL_PLnaxuqmda8jm701RqWadI-Qbaznme2sd6-3Yj6Kk9d9gfj_f85c73umi3Sr7J_wXKDh7hQ</recordid><startdate>201106</startdate><enddate>201106</enddate><creator>De La Fuente Herman, T</creator><creator>Ortega, H</creator><creator>Thompson, S</creator><creator>Herman, T</creator><creator>Ahmad, S</creator><general>American Association of Physicists in Medicine</general><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>201106</creationdate><title>SU‐D‐110‐06: Delineation of Target Volume Based on FDG PET‐CT Images and Its Effect on Tumor and Normal Tissue Doses</title><author>De La Fuente Herman, T ; Ortega, H ; Thompson, S ; Herman, T ; Ahmad, S</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c1772-e1c0febdeaccef75891d05f32e626ddab20ec64b9da178317100438d798f42d3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2011</creationdate><topic>Cancer</topic><topic>Computed tomography</topic><topic>Lungs</topic><topic>Medical imaging</topic><topic>Positron emission tomography</topic><topic>Radiopharmaceuticals</topic><topic>Tissues</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>De La Fuente Herman, T</creatorcontrib><creatorcontrib>Ortega, H</creatorcontrib><creatorcontrib>Thompson, S</creatorcontrib><creatorcontrib>Herman, T</creatorcontrib><creatorcontrib>Ahmad, S</creatorcontrib><collection>CrossRef</collection><jtitle>Medical Physics</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>De La Fuente Herman, T</au><au>Ortega, H</au><au>Thompson, S</au><au>Herman, T</au><au>Ahmad, S</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>SU‐D‐110‐06: Delineation of Target Volume Based on FDG PET‐CT Images and Its Effect on Tumor and Normal Tissue Doses</atitle><jtitle>Medical Physics</jtitle><date>2011-06</date><risdate>2011</risdate><volume>38</volume><issue>6</issue><spage>3388</spage><epage>3388</epage><pages>3388-3388</pages><issn>0094-2405</issn><eissn>2473-4209</eissn><coden>MPHYA6</coden><abstract>Purpose: To evaluate the effect of FDG PET‐CT imaging on target volume definition, inter and intra observer perceptions, and on tumor and normal tissue doses. Methods: The positron emission tomography with fluorine‐18‐ fluorodeoxyglucose (18F‐FDG) radiopharmaceutical and computed tomography (CT) combined provide structural and functional information for the definition of tumor and radio‐resistant regions that can be treated to high doses. This study uses data from twenty patients who had CT and PET imaging for treatment plan preparation. Treatment plans used non‐opposing co‐planar beams of four to seven fields. The prescribed dose was 70.2 Gy in 39 fractions. Physicians H and T independently delineated tumor volumes on CT and PET‐CT images and treatment plans were generated. Doses to CT contoured structures were obtained from plans that were originally planned based on contoured PET‐CT fused images. Tumor volumes of PET‐ CT and CT were compared by an index of agreement (IA). The intra and inter observer variations on tumor delineation, mean, minimum and maximum tumor doses, and percent differences in uninvolved lung doses were compared. Results: The mean intra observer IA value was approximately 0.50 for both physicians. The mean inter observer IA value was 0.45 and 0.52 for CT and fused PET‐CT tumor outlining respectively. The percent differences in average minimum and mean tumor doses for PET‐CT and CT plans were 60.1% and 8.1% respectively for physician H, and 78.4% and 11.7% respectively for physician T. The uninvolved lung mean dose variations for PET‐CT and CT plans were 5.6% and 1.9% for physicians H and T respectively, and between both physicians the differences were 9.6% and 12.7% for PET‐CT and CT plans respectively. Conclusions: The volumes created on PET‐CT images by two experienced physicians were greatly different compared to volumes created on CT only, resulting in extreme differences in calculated doses.</abstract><pub>American Association of Physicists in Medicine</pub><doi>10.1118/1.3611542</doi><tpages>1</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0094-2405 |
ispartof | Medical Physics, 2011-06, Vol.38 (6), p.3388-3388 |
issn | 0094-2405 2473-4209 |
language | eng |
recordid | cdi_crossref_primary_10_1118_1_3611542 |
source | Wiley |
subjects | Cancer Computed tomography Lungs Medical imaging Positron emission tomography Radiopharmaceuticals Tissues |
title | SU‐D‐110‐06: Delineation of Target Volume Based on FDG PET‐CT Images and Its Effect on Tumor and Normal Tissue Doses |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-24T18%3A22%3A46IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-wiley_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=SU%E2%80%90D%E2%80%90110%E2%80%9006:%20Delineation%20of%20Target%20Volume%20Based%20on%20FDG%20PET%E2%80%90CT%20Images%20and%20Its%20Effect%20on%20Tumor%20and%20Normal%20Tissue%20Doses&rft.jtitle=Medical%20Physics&rft.au=De%20La%20Fuente%20Herman,%20T&rft.date=2011-06&rft.volume=38&rft.issue=6&rft.spage=3388&rft.epage=3388&rft.pages=3388-3388&rft.issn=0094-2405&rft.eissn=2473-4209&rft.coden=MPHYA6&rft_id=info:doi/10.1118/1.3611542&rft_dat=%3Cwiley_cross%3EMP1542%3C/wiley_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c1772-e1c0febdeaccef75891d05f32e626ddab20ec64b9da178317100438d798f42d3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true |