Loading…
Effects of bilateral cochlear implants on vocal intensity control
Bilateral Cochlear Implants (BiCIs) can improve many perceptual tasks, including speech perception in noise, when compared to unilateral implantation. However, evidence suggests that BiCI users may perform worse on some vocal tasks, such as F0 production, than when using their better ear alone. This...
Saved in:
Published in: | The Journal of the Acoustical Society of America 2023-03, Vol.153 (3_supplement), p.A296-A296 |
---|---|
Main Authors: | , |
Format: | Article |
Language: | English |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | |
---|---|
cites | |
container_end_page | A296 |
container_issue | 3_supplement |
container_start_page | A296 |
container_title | The Journal of the Acoustical Society of America |
container_volume | 153 |
creator | Soleimanifar, Simin Aronoff, Justin M. |
description | Bilateral Cochlear Implants (BiCIs) can improve many perceptual tasks, including speech perception in noise, when compared to unilateral implantation. However, evidence suggests that BiCI users may perform worse on some vocal tasks, such as F0 production, than when using their better ear alone. This research aimed to determine if this detrimental effect on vocal control with BiCI devices extends to the control of vocal amplitude variations. Ten BiCI users were asked to produce a sustained vowel vocalization using both CIs and one CI separately. Their recordings were analyzed acoustically to determine long-term control of amplitude variations using the Variation of Peak Amplitude (vAm). The preliminary findings showed that using both CIs resulted in less control over vocal intensity for eight participants when compared to using one ear alone. The other two participants either showed no difference between the conditions or had a higher vAm with the unilateral ear than with the bilateral condition. The result suggests that BiCI use might detrimentally affect controlling long-term vocal intensity variation beyond any effects of unilateral CIs. Further investigation is needed to address how the vocal intensity control in BiCI users is affected. |
doi_str_mv | 10.1121/10.0018914 |
format | article |
fullrecord | <record><control><sourceid>crossref</sourceid><recordid>TN_cdi_crossref_primary_10_1121_10_0018914</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>10_1121_10_0018914</sourcerecordid><originalsourceid>FETCH-crossref_primary_10_1121_10_00189143</originalsourceid><addsrcrecordid>eNqVjksKwjAURR-iYP1MXEHGQm1ef7RDkYoLcF5iSDCSJiUJQndvCt2Ao8O95w4uwAnpBTHHLJJSbFosV5BgldO0qfJyDQmNdVq2db2FnfefGKumaBO4dlIKHjyxkryUZkE4pgm3_K0Fc0QNo2Zm1oZ8LY9KmSCMV2GKIxOc1QfYSKa9OC7cw_nePW-PlDvrvROyH50amJt6pP18cuZysvhr_APWYkGv</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Effects of bilateral cochlear implants on vocal intensity control</title><source>American Institute of Physics:Jisc Collections:Transitional Journals Agreement 2021-23 (Reading list)</source><creator>Soleimanifar, Simin ; Aronoff, Justin M.</creator><creatorcontrib>Soleimanifar, Simin ; Aronoff, Justin M.</creatorcontrib><description>Bilateral Cochlear Implants (BiCIs) can improve many perceptual tasks, including speech perception in noise, when compared to unilateral implantation. However, evidence suggests that BiCI users may perform worse on some vocal tasks, such as F0 production, than when using their better ear alone. This research aimed to determine if this detrimental effect on vocal control with BiCI devices extends to the control of vocal amplitude variations. Ten BiCI users were asked to produce a sustained vowel vocalization using both CIs and one CI separately. Their recordings were analyzed acoustically to determine long-term control of amplitude variations using the Variation of Peak Amplitude (vAm). The preliminary findings showed that using both CIs resulted in less control over vocal intensity for eight participants when compared to using one ear alone. The other two participants either showed no difference between the conditions or had a higher vAm with the unilateral ear than with the bilateral condition. The result suggests that BiCI use might detrimentally affect controlling long-term vocal intensity variation beyond any effects of unilateral CIs. Further investigation is needed to address how the vocal intensity control in BiCI users is affected.</description><identifier>ISSN: 0001-4966</identifier><identifier>EISSN: 1520-8524</identifier><identifier>DOI: 10.1121/10.0018914</identifier><language>eng</language><ispartof>The Journal of the Acoustical Society of America, 2023-03, Vol.153 (3_supplement), p.A296-A296</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids></links><search><creatorcontrib>Soleimanifar, Simin</creatorcontrib><creatorcontrib>Aronoff, Justin M.</creatorcontrib><title>Effects of bilateral cochlear implants on vocal intensity control</title><title>The Journal of the Acoustical Society of America</title><description>Bilateral Cochlear Implants (BiCIs) can improve many perceptual tasks, including speech perception in noise, when compared to unilateral implantation. However, evidence suggests that BiCI users may perform worse on some vocal tasks, such as F0 production, than when using their better ear alone. This research aimed to determine if this detrimental effect on vocal control with BiCI devices extends to the control of vocal amplitude variations. Ten BiCI users were asked to produce a sustained vowel vocalization using both CIs and one CI separately. Their recordings were analyzed acoustically to determine long-term control of amplitude variations using the Variation of Peak Amplitude (vAm). The preliminary findings showed that using both CIs resulted in less control over vocal intensity for eight participants when compared to using one ear alone. The other two participants either showed no difference between the conditions or had a higher vAm with the unilateral ear than with the bilateral condition. The result suggests that BiCI use might detrimentally affect controlling long-term vocal intensity variation beyond any effects of unilateral CIs. Further investigation is needed to address how the vocal intensity control in BiCI users is affected.</description><issn>0001-4966</issn><issn>1520-8524</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2023</creationdate><recordtype>article</recordtype><recordid>eNqVjksKwjAURR-iYP1MXEHGQm1ef7RDkYoLcF5iSDCSJiUJQndvCt2Ao8O95w4uwAnpBTHHLJJSbFosV5BgldO0qfJyDQmNdVq2db2FnfefGKumaBO4dlIKHjyxkryUZkE4pgm3_K0Fc0QNo2Zm1oZ8LY9KmSCMV2GKIxOc1QfYSKa9OC7cw_nePW-PlDvrvROyH50amJt6pP18cuZysvhr_APWYkGv</recordid><startdate>20230301</startdate><enddate>20230301</enddate><creator>Soleimanifar, Simin</creator><creator>Aronoff, Justin M.</creator><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>20230301</creationdate><title>Effects of bilateral cochlear implants on vocal intensity control</title><author>Soleimanifar, Simin ; Aronoff, Justin M.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-crossref_primary_10_1121_10_00189143</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2023</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Soleimanifar, Simin</creatorcontrib><creatorcontrib>Aronoff, Justin M.</creatorcontrib><collection>CrossRef</collection><jtitle>The Journal of the Acoustical Society of America</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Soleimanifar, Simin</au><au>Aronoff, Justin M.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Effects of bilateral cochlear implants on vocal intensity control</atitle><jtitle>The Journal of the Acoustical Society of America</jtitle><date>2023-03-01</date><risdate>2023</risdate><volume>153</volume><issue>3_supplement</issue><spage>A296</spage><epage>A296</epage><pages>A296-A296</pages><issn>0001-4966</issn><eissn>1520-8524</eissn><abstract>Bilateral Cochlear Implants (BiCIs) can improve many perceptual tasks, including speech perception in noise, when compared to unilateral implantation. However, evidence suggests that BiCI users may perform worse on some vocal tasks, such as F0 production, than when using their better ear alone. This research aimed to determine if this detrimental effect on vocal control with BiCI devices extends to the control of vocal amplitude variations. Ten BiCI users were asked to produce a sustained vowel vocalization using both CIs and one CI separately. Their recordings were analyzed acoustically to determine long-term control of amplitude variations using the Variation of Peak Amplitude (vAm). The preliminary findings showed that using both CIs resulted in less control over vocal intensity for eight participants when compared to using one ear alone. The other two participants either showed no difference between the conditions or had a higher vAm with the unilateral ear than with the bilateral condition. The result suggests that BiCI use might detrimentally affect controlling long-term vocal intensity variation beyond any effects of unilateral CIs. Further investigation is needed to address how the vocal intensity control in BiCI users is affected.</abstract><doi>10.1121/10.0018914</doi></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0001-4966 |
ispartof | The Journal of the Acoustical Society of America, 2023-03, Vol.153 (3_supplement), p.A296-A296 |
issn | 0001-4966 1520-8524 |
language | eng |
recordid | cdi_crossref_primary_10_1121_10_0018914 |
source | American Institute of Physics:Jisc Collections:Transitional Journals Agreement 2021-23 (Reading list) |
title | Effects of bilateral cochlear implants on vocal intensity control |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-07T17%3A22%3A05IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-crossref&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Effects%20of%20bilateral%20cochlear%20implants%20on%20vocal%20intensity%20control&rft.jtitle=The%20Journal%20of%20the%20Acoustical%20Society%20of%20America&rft.au=Soleimanifar,%20Simin&rft.date=2023-03-01&rft.volume=153&rft.issue=3_supplement&rft.spage=A296&rft.epage=A296&rft.pages=A296-A296&rft.issn=0001-4966&rft.eissn=1520-8524&rft_id=info:doi/10.1121/10.0018914&rft_dat=%3Ccrossref%3E10_1121_10_0018914%3C/crossref%3E%3Cgrp_id%3Ecdi_FETCH-crossref_primary_10_1121_10_00189143%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true |