Loading…

Multichannel wire gas electron multipliers

A simple technique for manufacturing electrodes of multichannel wire gas electron multipliers was developed. The maximum proportional multiplication factor of ionization electrons K max = 10 3 was obtained when the chamber containing a multichannel wire gas electron multiplier was filled with a mixt...

Full description

Saved in:
Bibliographic Details
Published in:Instruments and experimental techniques (New York) 2013-11, Vol.56 (6), p.634-636
Main Authors: Ovchinnikov, B. M., Parusov, V. V.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:A simple technique for manufacturing electrodes of multichannel wire gas electron multipliers was developed. The maximum proportional multiplication factor of ionization electrons K max = 10 3 was obtained when the chamber containing a multichannel wire gas electron multiplier was filled with a mixture of Ar + 10%C 2 H 4 at a pressure of 1 atm (abs.) and the drift (ionization) gap of the chamber was irradiated with β particles ( 63 Ni). Under irradiation with α particles, K max = 10 3 at a pressure of 1 atm (abs.) and 3 × 10 3 at 0.4 atm (abs.). When the chamber was filled with a mixture of Ne + 10%C 2 H 4 at a pressure of 1 atm (abs.) and exposed to β particles, K max = 4 × 10 3 was obtained.
ISSN:0020-4412
1608-3180
DOI:10.1134/S0020441214010096