Measures for ensuring reliable operation of the welded joint connecting the reactor coolant circuit’s header to the shell of a steam generator used at a VVER-1000 reactor-based nuclear power station

Problems that arose around the weld joint connecting the reactor coolant circuit’s header to the steam generator shell during operation of steam generators at nuclear power stations equipped with VVER-1000 reactors are considered. Works on studying the defects occurred in the header’s metal are desc...

Full description

Saved in:
Bibliographic Details
Published in:Thermal engineering 2011, Vol.58 (3), p.208-214
Main Authors: Kharchenko, S. A., Trunov, N. B., Korotaev, N. F., Lyakishev, S. L.
Format: Article
Language:English
Subjects:
Citations: Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Problems that arose around the weld joint connecting the reactor coolant circuit’s header to the steam generator shell during operation of steam generators at nuclear power stations equipped with VVER-1000 reactors are considered. Works on studying the defects occurred in the header’s metal are described, and ways for preventing their development are determined.