Loading…
Measures for ensuring reliable operation of the welded joint connecting the reactor coolant circuit’s header to the shell of a steam generator used at a VVER-1000 reactor-based nuclear power station
Problems that arose around the weld joint connecting the reactor coolant circuit’s header to the steam generator shell during operation of steam generators at nuclear power stations equipped with VVER-1000 reactors are considered. Works on studying the defects occurred in the header’s metal are desc...
Saved in:
Published in: | Thermal engineering 2011, Vol.58 (3), p.208-214 |
---|---|
Main Authors: | , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Problems that arose around the weld joint connecting the reactor coolant circuit’s header to the steam generator shell during operation of steam generators at nuclear power stations equipped with VVER-1000 reactors are considered. Works on studying the defects occurred in the header’s metal are described, and ways for preventing their development are determined. |
---|---|
ISSN: | 0040-6015 1555-6301 |
DOI: | 10.1134/S0040601511030062 |