Loading…

Formation of the nutation line in NMR measuring systems with flowing samples

In this Letter, we present the results of investigations of the influence of the magnetic field intensity and inhomogeneity in the zone of the nutation coil location on the nutation line shape for different relaxation constants and temperatures of the flowing liquid. It is shown experimentally that...

Full description

Saved in:
Bibliographic Details
Published in:Technical physics letters 2015-04, Vol.41 (4), p.355-358
Main Authors: Davydov, V. V., Dudkin, V. I., Karseev, A. Yu
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c288t-4992e51746e5c9dccd9c6d5b2c6b183bec8dd093dfebcadbf5bbd8664aebbf903
cites cdi_FETCH-LOGICAL-c288t-4992e51746e5c9dccd9c6d5b2c6b183bec8dd093dfebcadbf5bbd8664aebbf903
container_end_page 358
container_issue 4
container_start_page 355
container_title Technical physics letters
container_volume 41
creator Davydov, V. V.
Dudkin, V. I.
Karseev, A. Yu
description In this Letter, we present the results of investigations of the influence of the magnetic field intensity and inhomogeneity in the zone of the nutation coil location on the nutation line shape for different relaxation constants and temperatures of the flowing liquid. It is shown experimentally that the nutation line shape in NMR measuring systems is independent of changes in transverse relaxation time T 2 of the flowing liquid.
doi_str_mv 10.1134/S1063785015040057
format article
fullrecord <record><control><sourceid>crossref_sprin</sourceid><recordid>TN_cdi_crossref_primary_10_1134_S1063785015040057</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>10_1134_S1063785015040057</sourcerecordid><originalsourceid>FETCH-LOGICAL-c288t-4992e51746e5c9dccd9c6d5b2c6b183bec8dd093dfebcadbf5bbd8664aebbf903</originalsourceid><addsrcrecordid>eNp9kMtOwzAQRS0EEqXwAez8A4FxHDv2ElUUkAJIPNaRH2OaKo_KTlX172koOyRWc2dGZ3TnEnLN4IYxXty-M5C8VAKYgAJAlCdkxkBDJgXnp5OWPJv25-QipTUAqFzoGamWQ-zM2Aw9HQIdV0j77Xjs26ZH2vT05fmNdmjSNjb9F037NGKX6K4ZVzS0w-5naLpNi-mSnAXTJrz6rXPyubz_WDxm1evD0-Kuylyu1JgVWucoWFlIFE5757x20gubO2mZ4had8h409wGtM94GYa1XUhYGrQ0a-Jyw410Xh5QihnoTm87Efc2gnuKo_8RxYPIjkzbTHxjr9bCN_cHmP9A3rW5jzQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Formation of the nutation line in NMR measuring systems with flowing samples</title><source>Springer Nature</source><creator>Davydov, V. V. ; Dudkin, V. I. ; Karseev, A. Yu</creator><creatorcontrib>Davydov, V. V. ; Dudkin, V. I. ; Karseev, A. Yu</creatorcontrib><description>In this Letter, we present the results of investigations of the influence of the magnetic field intensity and inhomogeneity in the zone of the nutation coil location on the nutation line shape for different relaxation constants and temperatures of the flowing liquid. It is shown experimentally that the nutation line shape in NMR measuring systems is independent of changes in transverse relaxation time T 2 of the flowing liquid.</description><identifier>ISSN: 1063-7850</identifier><identifier>EISSN: 1090-6533</identifier><identifier>DOI: 10.1134/S1063785015040057</identifier><language>eng</language><publisher>Moscow: Pleiades Publishing</publisher><subject>Classical and Continuum Physics ; Physics ; Physics and Astronomy</subject><ispartof>Technical physics letters, 2015-04, Vol.41 (4), p.355-358</ispartof><rights>Pleiades Publishing, Ltd. 2015</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c288t-4992e51746e5c9dccd9c6d5b2c6b183bec8dd093dfebcadbf5bbd8664aebbf903</citedby><cites>FETCH-LOGICAL-c288t-4992e51746e5c9dccd9c6d5b2c6b183bec8dd093dfebcadbf5bbd8664aebbf903</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids></links><search><creatorcontrib>Davydov, V. V.</creatorcontrib><creatorcontrib>Dudkin, V. I.</creatorcontrib><creatorcontrib>Karseev, A. Yu</creatorcontrib><title>Formation of the nutation line in NMR measuring systems with flowing samples</title><title>Technical physics letters</title><addtitle>Tech. Phys. Lett</addtitle><description>In this Letter, we present the results of investigations of the influence of the magnetic field intensity and inhomogeneity in the zone of the nutation coil location on the nutation line shape for different relaxation constants and temperatures of the flowing liquid. It is shown experimentally that the nutation line shape in NMR measuring systems is independent of changes in transverse relaxation time T 2 of the flowing liquid.</description><subject>Classical and Continuum Physics</subject><subject>Physics</subject><subject>Physics and Astronomy</subject><issn>1063-7850</issn><issn>1090-6533</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2015</creationdate><recordtype>article</recordtype><recordid>eNp9kMtOwzAQRS0EEqXwAez8A4FxHDv2ElUUkAJIPNaRH2OaKo_KTlX172koOyRWc2dGZ3TnEnLN4IYxXty-M5C8VAKYgAJAlCdkxkBDJgXnp5OWPJv25-QipTUAqFzoGamWQ-zM2Aw9HQIdV0j77Xjs26ZH2vT05fmNdmjSNjb9F037NGKX6K4ZVzS0w-5naLpNi-mSnAXTJrz6rXPyubz_WDxm1evD0-Kuylyu1JgVWucoWFlIFE5757x20gubO2mZ4had8h409wGtM94GYa1XUhYGrQ0a-Jyw410Xh5QihnoTm87Efc2gnuKo_8RxYPIjkzbTHxjr9bCN_cHmP9A3rW5jzQ</recordid><startdate>20150401</startdate><enddate>20150401</enddate><creator>Davydov, V. V.</creator><creator>Dudkin, V. I.</creator><creator>Karseev, A. Yu</creator><general>Pleiades Publishing</general><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>20150401</creationdate><title>Formation of the nutation line in NMR measuring systems with flowing samples</title><author>Davydov, V. V. ; Dudkin, V. I. ; Karseev, A. Yu</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c288t-4992e51746e5c9dccd9c6d5b2c6b183bec8dd093dfebcadbf5bbd8664aebbf903</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2015</creationdate><topic>Classical and Continuum Physics</topic><topic>Physics</topic><topic>Physics and Astronomy</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Davydov, V. V.</creatorcontrib><creatorcontrib>Dudkin, V. I.</creatorcontrib><creatorcontrib>Karseev, A. Yu</creatorcontrib><collection>CrossRef</collection><jtitle>Technical physics letters</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Davydov, V. V.</au><au>Dudkin, V. I.</au><au>Karseev, A. Yu</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Formation of the nutation line in NMR measuring systems with flowing samples</atitle><jtitle>Technical physics letters</jtitle><stitle>Tech. Phys. Lett</stitle><date>2015-04-01</date><risdate>2015</risdate><volume>41</volume><issue>4</issue><spage>355</spage><epage>358</epage><pages>355-358</pages><issn>1063-7850</issn><eissn>1090-6533</eissn><abstract>In this Letter, we present the results of investigations of the influence of the magnetic field intensity and inhomogeneity in the zone of the nutation coil location on the nutation line shape for different relaxation constants and temperatures of the flowing liquid. It is shown experimentally that the nutation line shape in NMR measuring systems is independent of changes in transverse relaxation time T 2 of the flowing liquid.</abstract><cop>Moscow</cop><pub>Pleiades Publishing</pub><doi>10.1134/S1063785015040057</doi><tpages>4</tpages></addata></record>
fulltext fulltext
identifier ISSN: 1063-7850
ispartof Technical physics letters, 2015-04, Vol.41 (4), p.355-358
issn 1063-7850
1090-6533
language eng
recordid cdi_crossref_primary_10_1134_S1063785015040057
source Springer Nature
subjects Classical and Continuum Physics
Physics
Physics and Astronomy
title Formation of the nutation line in NMR measuring systems with flowing samples
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-08T05%3A17%3A35IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-crossref_sprin&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Formation%20of%20the%20nutation%20line%20in%20NMR%20measuring%20systems%20with%20flowing%20samples&rft.jtitle=Technical%20physics%20letters&rft.au=Davydov,%20V.%20V.&rft.date=2015-04-01&rft.volume=41&rft.issue=4&rft.spage=355&rft.epage=358&rft.pages=355-358&rft.issn=1063-7850&rft.eissn=1090-6533&rft_id=info:doi/10.1134/S1063785015040057&rft_dat=%3Ccrossref_sprin%3E10_1134_S1063785015040057%3C/crossref_sprin%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c288t-4992e51746e5c9dccd9c6d5b2c6b183bec8dd093dfebcadbf5bbd8664aebbf903%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true