Measurement of Ionization and Attachment Coefficients in SF 6 and Xenon Gas Mixtures
The Townsend first ionization coefficient α, electron attachment coefficient η and effective ionization coefficient α (=α-η) in SF 6 and xenon gas mixtures were measured by the steady-state Townsend method for 22.6 \leqslant E / p \leqslant94 V·mm -1 ·kPa -1 and mixture ratios of 10:90, 25:75, 50:50...
Saved in:
Published in: | Japanese Journal of Applied Physics 1999-08, Vol.38 (8A), p.L875 |
---|---|
Main Authors: | , , |
Format: | Article |
Language: | English |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | The Townsend first ionization coefficient α, electron attachment coefficient η and effective ionization
coefficient α (=α-η) in SF
6
and xenon gas mixtures were measured by the steady-state Townsend method
for 22.6 \leqslant
E
/
p
\leqslant94 V·mm
-1
·kPa
-1
and mixture ratios of 10:90, 25:75, 50:50, 75:25 and 90:10. The limiting
E
/
p
in SF
6
-Xe, (
E
/
p
)
lim
, which represents
E
/
p
for α/
P
=
n
/
P
, was derived from the pre-breakdown current growth
measurements, which varies approximately linearly with SF
6
concentration in the SF
6
-Xe gas mixtures. |
---|---|
ISSN: | 0021-4922 1347-4065 |