Lithium-Ion Cell Nail Penetration Safety Experiments under Adiabatic Conditions
Nail penetration tests under adiabatic conditions are proposed as a new safety test method to simulate a short circuit caused by intrusion in the worst case scenario, i.e., adiabatic conditions. The behaviors of commercially available 18650 type lithium-ion cells with two different cell chemistries,...
Saved in:
Main Authors: | , , , , , , , , |
---|---|
Format: | Conference Proceeding |
Language: | English |
Citations: | Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Nail penetration tests under adiabatic conditions are proposed as a new safety test method to simulate a short circuit caused by intrusion in the worst case scenario, i.e., adiabatic conditions. The behaviors of commercially available 18650 type lithium-ion cells with two different cell chemistries, LiNi
0.33
Co
0.33
Mn
0.33
O
2
- LiCoO
2
blend (NCM-LCO blend) vs. graphite and LiFePO
4
(LFP) vs. graphite, were investigated at different states of charge (SoC). The results show a small standard deviation for the temperature and pressure measurements from five identical experiments. The detailed examination of the nail penetration experiments reveals differences in the safety properties of the cathode materials (LFP vs. NCM-LCO), separator types (PP PE PP trilayer vs. PE single layer) and electrode designs (high power vs. high energy). For both cell types, the observed cooling effect at high energy contents could be linked to an increased gas production due to the loss of electrolyte. |
---|---|
ISSN: | 1938-5862 1938-6737 |
DOI: | 10.1149/06127.0087ecst |