Loading…

Square Diaphragm CMUT Capacitance Calculation Using a New Deflection Shape Function

A new highly accurate closed-form capacitance calculation model has been developed to calculate the capacitance of capacitive micromachined ultrasonic transducers (CMUTs) built with square diaphragms. The model has been developed by using a two-dimensional polynomial function that more accurately pr...

Full description

Saved in:
Bibliographic Details
Published in:Journal of sensors 2011-01, Vol.2011 (2011), p.1-12
Main Authors: Rahman, Md Mosaddequr, Chowdhury, Sazzadur
Format: Article
Language:English
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-a396t-66fd098868e690da12b18d29b00dd9b59e3a42f85ce48fc3f53ebd1152ea1c133
cites cdi_FETCH-LOGICAL-a396t-66fd098868e690da12b18d29b00dd9b59e3a42f85ce48fc3f53ebd1152ea1c133
container_end_page 12
container_issue 2011
container_start_page 1
container_title Journal of sensors
container_volume 2011
creator Rahman, Md Mosaddequr
Chowdhury, Sazzadur
description A new highly accurate closed-form capacitance calculation model has been developed to calculate the capacitance of capacitive micromachined ultrasonic transducers (CMUTs) built with square diaphragms. The model has been developed by using a two-dimensional polynomial function that more accurately predicts the deflection curve of a square diaphragm deformed under the influence of a uniform external pressure and also takes account of the fringing field capacitances. The model has been verified by comparing the model-predicted deflection profiles and capacitance values with experimental results published elsewhere and finite element analysis (FEA) carried out by the authors for different material properties, geometric specifications, and loading conditions. New model-calculated capacitance values are found to be in excellent agreement with published experimental results with a maximum deviation of 1.7%, and a maximum deviation of 1.5% has been observed when compared with FEA results. The model can help in improving the accuracy of the design methodology of CMUT devices and other MEMS-based capacitive type sensors built with square diaphragms.
doi_str_mv 10.1155/2011/581910
format article
fullrecord <record><control><sourceid>emarefa_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1155_2011_581910</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>482543</sourcerecordid><originalsourceid>FETCH-LOGICAL-a396t-66fd098868e690da12b18d29b00dd9b59e3a42f85ce48fc3f53ebd1152ea1c133</originalsourceid><addsrcrecordid>eNqFkE1PwkAQhjdGExE9eTbZs6ayH91l92gKqAnqAUi8NdPdWagppbYQ4r-3UMPV07zz5skk8xByy9kj50oNBON8oAy3nJ2RHtdmGA2FNuenrD4vyVXTfDGm5VDKHpnNvndQIx3lUK1qWK5p8raY0wQqcPkWSodtLtyugG2-KemiycslBfqOezrCUKA71rMVVEgnu_K4XpOLAEWDN3-zTxaT8Tx5iaYfz6_J0zQCafU20jp4Zo3RBrVlHrjIuPHCZox5bzNlUUIsglEOYxOcDEpi5ts_BQJ3XMo-eejuunrTNDWGtKrzNdQ_KWfpwUd68JF2Plr6vqNXeelhn_8D33UwtggGOMGxESqW8heUPmjP</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Square Diaphragm CMUT Capacitance Calculation Using a New Deflection Shape Function</title><source>Wiley Online Library Open Access</source><source>Publicly Available Content Database</source><creator>Rahman, Md Mosaddequr ; Chowdhury, Sazzadur</creator><contributor>Dücső, Csaba</contributor><creatorcontrib>Rahman, Md Mosaddequr ; Chowdhury, Sazzadur ; Dücső, Csaba</creatorcontrib><description>A new highly accurate closed-form capacitance calculation model has been developed to calculate the capacitance of capacitive micromachined ultrasonic transducers (CMUTs) built with square diaphragms. The model has been developed by using a two-dimensional polynomial function that more accurately predicts the deflection curve of a square diaphragm deformed under the influence of a uniform external pressure and also takes account of the fringing field capacitances. The model has been verified by comparing the model-predicted deflection profiles and capacitance values with experimental results published elsewhere and finite element analysis (FEA) carried out by the authors for different material properties, geometric specifications, and loading conditions. New model-calculated capacitance values are found to be in excellent agreement with published experimental results with a maximum deviation of 1.7%, and a maximum deviation of 1.5% has been observed when compared with FEA results. The model can help in improving the accuracy of the design methodology of CMUT devices and other MEMS-based capacitive type sensors built with square diaphragms.</description><identifier>ISSN: 1687-725X</identifier><identifier>EISSN: 1687-7268</identifier><identifier>DOI: 10.1155/2011/581910</identifier><language>eng</language><publisher>Cairo, Egypt: Hindawi Puplishing Corporation</publisher><ispartof>Journal of sensors, 2011-01, Vol.2011 (2011), p.1-12</ispartof><rights>Copyright © 2011 Md Mosaddequr Rahman and Sazzadur Chowdhury.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-a396t-66fd098868e690da12b18d29b00dd9b59e3a42f85ce48fc3f53ebd1152ea1c133</citedby><cites>FETCH-LOGICAL-a396t-66fd098868e690da12b18d29b00dd9b59e3a42f85ce48fc3f53ebd1152ea1c133</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids></links><search><contributor>Dücső, Csaba</contributor><creatorcontrib>Rahman, Md Mosaddequr</creatorcontrib><creatorcontrib>Chowdhury, Sazzadur</creatorcontrib><title>Square Diaphragm CMUT Capacitance Calculation Using a New Deflection Shape Function</title><title>Journal of sensors</title><description>A new highly accurate closed-form capacitance calculation model has been developed to calculate the capacitance of capacitive micromachined ultrasonic transducers (CMUTs) built with square diaphragms. The model has been developed by using a two-dimensional polynomial function that more accurately predicts the deflection curve of a square diaphragm deformed under the influence of a uniform external pressure and also takes account of the fringing field capacitances. The model has been verified by comparing the model-predicted deflection profiles and capacitance values with experimental results published elsewhere and finite element analysis (FEA) carried out by the authors for different material properties, geometric specifications, and loading conditions. New model-calculated capacitance values are found to be in excellent agreement with published experimental results with a maximum deviation of 1.7%, and a maximum deviation of 1.5% has been observed when compared with FEA results. The model can help in improving the accuracy of the design methodology of CMUT devices and other MEMS-based capacitive type sensors built with square diaphragms.</description><issn>1687-725X</issn><issn>1687-7268</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2011</creationdate><recordtype>article</recordtype><recordid>eNqFkE1PwkAQhjdGExE9eTbZs6ayH91l92gKqAnqAUi8NdPdWagppbYQ4r-3UMPV07zz5skk8xByy9kj50oNBON8oAy3nJ2RHtdmGA2FNuenrD4vyVXTfDGm5VDKHpnNvndQIx3lUK1qWK5p8raY0wQqcPkWSodtLtyugG2-KemiycslBfqOezrCUKA71rMVVEgnu_K4XpOLAEWDN3-zTxaT8Tx5iaYfz6_J0zQCafU20jp4Zo3RBrVlHrjIuPHCZox5bzNlUUIsglEOYxOcDEpi5ts_BQJ3XMo-eejuunrTNDWGtKrzNdQ_KWfpwUd68JF2Plr6vqNXeelhn_8D33UwtggGOMGxESqW8heUPmjP</recordid><startdate>20110101</startdate><enddate>20110101</enddate><creator>Rahman, Md Mosaddequr</creator><creator>Chowdhury, Sazzadur</creator><general>Hindawi Puplishing Corporation</general><general>Hindawi Publishing Corporation</general><scope>ADJCN</scope><scope>AHFXO</scope><scope>RHU</scope><scope>RHW</scope><scope>RHX</scope><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>20110101</creationdate><title>Square Diaphragm CMUT Capacitance Calculation Using a New Deflection Shape Function</title><author>Rahman, Md Mosaddequr ; Chowdhury, Sazzadur</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-a396t-66fd098868e690da12b18d29b00dd9b59e3a42f85ce48fc3f53ebd1152ea1c133</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2011</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Rahman, Md Mosaddequr</creatorcontrib><creatorcontrib>Chowdhury, Sazzadur</creatorcontrib><collection>الدوريات العلمية والإحصائية - e-Marefa Academic and Statistical Periodicals</collection><collection>معرفة - المحتوى العربي الأكاديمي المتكامل - e-Marefa Academic Complete</collection><collection>Hindawi Publishing Complete</collection><collection>Hindawi Publishing Subscription Journals</collection><collection>Hindawi Publishing Open Access</collection><collection>CrossRef</collection><jtitle>Journal of sensors</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Rahman, Md Mosaddequr</au><au>Chowdhury, Sazzadur</au><au>Dücső, Csaba</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Square Diaphragm CMUT Capacitance Calculation Using a New Deflection Shape Function</atitle><jtitle>Journal of sensors</jtitle><date>2011-01-01</date><risdate>2011</risdate><volume>2011</volume><issue>2011</issue><spage>1</spage><epage>12</epage><pages>1-12</pages><issn>1687-725X</issn><eissn>1687-7268</eissn><abstract>A new highly accurate closed-form capacitance calculation model has been developed to calculate the capacitance of capacitive micromachined ultrasonic transducers (CMUTs) built with square diaphragms. The model has been developed by using a two-dimensional polynomial function that more accurately predicts the deflection curve of a square diaphragm deformed under the influence of a uniform external pressure and also takes account of the fringing field capacitances. The model has been verified by comparing the model-predicted deflection profiles and capacitance values with experimental results published elsewhere and finite element analysis (FEA) carried out by the authors for different material properties, geometric specifications, and loading conditions. New model-calculated capacitance values are found to be in excellent agreement with published experimental results with a maximum deviation of 1.7%, and a maximum deviation of 1.5% has been observed when compared with FEA results. The model can help in improving the accuracy of the design methodology of CMUT devices and other MEMS-based capacitive type sensors built with square diaphragms.</abstract><cop>Cairo, Egypt</cop><pub>Hindawi Puplishing Corporation</pub><doi>10.1155/2011/581910</doi><tpages>12</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 1687-725X
ispartof Journal of sensors, 2011-01, Vol.2011 (2011), p.1-12
issn 1687-725X
1687-7268
language eng
recordid cdi_crossref_primary_10_1155_2011_581910
source Wiley Online Library Open Access; Publicly Available Content Database
title Square Diaphragm CMUT Capacitance Calculation Using a New Deflection Shape Function
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-04T05%3A38%3A32IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-emarefa_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Square%20Diaphragm%20CMUT%20Capacitance%20Calculation%20Using%20a%20New%20Deflection%20Shape%20Function&rft.jtitle=Journal%20of%20sensors&rft.au=Rahman,%20Md%20Mosaddequr&rft.date=2011-01-01&rft.volume=2011&rft.issue=2011&rft.spage=1&rft.epage=12&rft.pages=1-12&rft.issn=1687-725X&rft.eissn=1687-7268&rft_id=info:doi/10.1155/2011/581910&rft_dat=%3Cemarefa_cross%3E482543%3C/emarefa_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-a396t-66fd098868e690da12b18d29b00dd9b59e3a42f85ce48fc3f53ebd1152ea1c133%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true