The Calibration Index and Taxonomy for Robot Kinematic Calibration Methods
The major approaches toward kinematic calibration are unified by considering an end-point measurement system as forming a joint and closing the kinematic loop. A calibration index is in troduced, based on the mobility equation, that considers sensed and unsensed joints and single and multiple loops...
Saved in:
Published in: | The International journal of robotics research 1996-12, Vol.15 (6), p.573-591 |
---|---|
Main Authors: | , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c380t-c356f6259a32e71d81eefc863882b904c2afcda5e19ff57c26ad2e1240c240e53 |
---|---|
cites | cdi_FETCH-LOGICAL-c380t-c356f6259a32e71d81eefc863882b904c2afcda5e19ff57c26ad2e1240c240e53 |
container_end_page | 591 |
container_issue | 6 |
container_start_page | 573 |
container_title | The International journal of robotics research |
container_volume | 15 |
creator | Hollerbach, John M. Wampler, Charles W. |
description | The major approaches toward kinematic calibration are unified by considering an end-point measurement system as forming a joint and closing the kinematic loop. A calibration index is in troduced, based on the mobility equation, that considers sensed and unsensed joints and single and multiple loops and ex presses the surplus of measurements over degrees of freedom at each pose. Past work using open-loop calibration, closed-loop calibration, and screw axis measurement is classified according to this calibration index. Numerical issues are surveyed, in cluding task variable scaling, parameter variable scaling, rank determination, pose selection, and input noise handling. |
doi_str_mv | 10.1177/027836499601500604 |
format | article |
fullrecord | <record><control><sourceid>sage_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1177_027836499601500604</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sage_id>10.1177_027836499601500604</sage_id><sourcerecordid>10.1177_027836499601500604</sourcerecordid><originalsourceid>FETCH-LOGICAL-c380t-c356f6259a32e71d81eefc863882b904c2afcda5e19ff57c26ad2e1240c240e53</originalsourceid><addsrcrecordid>eNp9kE1LAzEQhoMoWKt_wFMOXtdOkt1kc5TiR7UiSD0v02xit7RJSVZo_31TKoIIHmbm8jwvzEvINYNbxpQaAVe1kKXWElgFIKE8IQOmSlYIpuQpGRyA4kCck4uUlgAgJOgBeZ4tLB3jqptH7Lvg6cS3dkvRt3SG2-DDekddiPQ9zENPXzpv15kzv5RX2y9Cmy7JmcNVslffd0g-Hu5n46di-vY4Gd9NCyNq6POupJO80ii4VaytmbXO1FLUNZ9rKA1HZ1qsLNPOVcpwiS23jJdg8thKDAk_5poYUorWNZvYrTHuGgbNoY3mbxtZujlKG0wGVy6iN136MXmVa9KQsdERS_hpm2X4ij6_8l_wHqcba_g</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>The Calibration Index and Taxonomy for Robot Kinematic Calibration Methods</title><source>SAGE Deep Backfile 2012</source><creator>Hollerbach, John M. ; Wampler, Charles W.</creator><creatorcontrib>Hollerbach, John M. ; Wampler, Charles W.</creatorcontrib><description>The major approaches toward kinematic calibration are unified by considering an end-point measurement system as forming a joint and closing the kinematic loop. A calibration index is in troduced, based on the mobility equation, that considers sensed and unsensed joints and single and multiple loops and ex presses the surplus of measurements over degrees of freedom at each pose. Past work using open-loop calibration, closed-loop calibration, and screw axis measurement is classified according to this calibration index. Numerical issues are surveyed, in cluding task variable scaling, parameter variable scaling, rank determination, pose selection, and input noise handling.</description><identifier>ISSN: 0278-3649</identifier><identifier>EISSN: 1741-3176</identifier><identifier>DOI: 10.1177/027836499601500604</identifier><identifier>CODEN: IJRREL</identifier><language>eng</language><publisher>Thousand Oaks, CA: Sage Publications</publisher><subject>Applied sciences ; Computer science; control theory; systems ; Control theory. Systems ; Exact sciences and technology ; Robotics</subject><ispartof>The International journal of robotics research, 1996-12, Vol.15 (6), p.573-591</ispartof><rights>1997 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c380t-c356f6259a32e71d81eefc863882b904c2afcda5e19ff57c26ad2e1240c240e53</citedby><cites>FETCH-LOGICAL-c380t-c356f6259a32e71d81eefc863882b904c2afcda5e19ff57c26ad2e1240c240e53</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://journals.sagepub.com/doi/pdf/10.1177/027836499601500604$$EPDF$$P50$$Gsage$$H</linktopdf><linktohtml>$$Uhttps://journals.sagepub.com/doi/10.1177/027836499601500604$$EHTML$$P50$$Gsage$$H</linktohtml><link.rule.ids>314,780,784,21845,27924,27925,45082,45470</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&idt=2517690$$DView record in Pascal Francis$$Hfree_for_read</backlink></links><search><creatorcontrib>Hollerbach, John M.</creatorcontrib><creatorcontrib>Wampler, Charles W.</creatorcontrib><title>The Calibration Index and Taxonomy for Robot Kinematic Calibration Methods</title><title>The International journal of robotics research</title><description>The major approaches toward kinematic calibration are unified by considering an end-point measurement system as forming a joint and closing the kinematic loop. A calibration index is in troduced, based on the mobility equation, that considers sensed and unsensed joints and single and multiple loops and ex presses the surplus of measurements over degrees of freedom at each pose. Past work using open-loop calibration, closed-loop calibration, and screw axis measurement is classified according to this calibration index. Numerical issues are surveyed, in cluding task variable scaling, parameter variable scaling, rank determination, pose selection, and input noise handling.</description><subject>Applied sciences</subject><subject>Computer science; control theory; systems</subject><subject>Control theory. Systems</subject><subject>Exact sciences and technology</subject><subject>Robotics</subject><issn>0278-3649</issn><issn>1741-3176</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1996</creationdate><recordtype>article</recordtype><recordid>eNp9kE1LAzEQhoMoWKt_wFMOXtdOkt1kc5TiR7UiSD0v02xit7RJSVZo_31TKoIIHmbm8jwvzEvINYNbxpQaAVe1kKXWElgFIKE8IQOmSlYIpuQpGRyA4kCck4uUlgAgJOgBeZ4tLB3jqptH7Lvg6cS3dkvRt3SG2-DDekddiPQ9zENPXzpv15kzv5RX2y9Cmy7JmcNVslffd0g-Hu5n46di-vY4Gd9NCyNq6POupJO80ii4VaytmbXO1FLUNZ9rKA1HZ1qsLNPOVcpwiS23jJdg8thKDAk_5poYUorWNZvYrTHuGgbNoY3mbxtZujlKG0wGVy6iN136MXmVa9KQsdERS_hpm2X4ij6_8l_wHqcba_g</recordid><startdate>19961201</startdate><enddate>19961201</enddate><creator>Hollerbach, John M.</creator><creator>Wampler, Charles W.</creator><general>Sage Publications</general><general>Sage Science</general><scope>IQODW</scope><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>19961201</creationdate><title>The Calibration Index and Taxonomy for Robot Kinematic Calibration Methods</title><author>Hollerbach, John M. ; Wampler, Charles W.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c380t-c356f6259a32e71d81eefc863882b904c2afcda5e19ff57c26ad2e1240c240e53</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1996</creationdate><topic>Applied sciences</topic><topic>Computer science; control theory; systems</topic><topic>Control theory. Systems</topic><topic>Exact sciences and technology</topic><topic>Robotics</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Hollerbach, John M.</creatorcontrib><creatorcontrib>Wampler, Charles W.</creatorcontrib><collection>Pascal-Francis</collection><collection>CrossRef</collection><jtitle>The International journal of robotics research</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Hollerbach, John M.</au><au>Wampler, Charles W.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>The Calibration Index and Taxonomy for Robot Kinematic Calibration Methods</atitle><jtitle>The International journal of robotics research</jtitle><date>1996-12-01</date><risdate>1996</risdate><volume>15</volume><issue>6</issue><spage>573</spage><epage>591</epage><pages>573-591</pages><issn>0278-3649</issn><eissn>1741-3176</eissn><coden>IJRREL</coden><abstract>The major approaches toward kinematic calibration are unified by considering an end-point measurement system as forming a joint and closing the kinematic loop. A calibration index is in troduced, based on the mobility equation, that considers sensed and unsensed joints and single and multiple loops and ex presses the surplus of measurements over degrees of freedom at each pose. Past work using open-loop calibration, closed-loop calibration, and screw axis measurement is classified according to this calibration index. Numerical issues are surveyed, in cluding task variable scaling, parameter variable scaling, rank determination, pose selection, and input noise handling.</abstract><cop>Thousand Oaks, CA</cop><pub>Sage Publications</pub><doi>10.1177/027836499601500604</doi><tpages>19</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0278-3649 |
ispartof | The International journal of robotics research, 1996-12, Vol.15 (6), p.573-591 |
issn | 0278-3649 1741-3176 |
language | eng |
recordid | cdi_crossref_primary_10_1177_027836499601500604 |
source | SAGE Deep Backfile 2012 |
subjects | Applied sciences Computer science control theory systems Control theory. Systems Exact sciences and technology Robotics |
title | The Calibration Index and Taxonomy for Robot Kinematic Calibration Methods |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-30T22%3A46%3A52IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-sage_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=The%20Calibration%20Index%20and%20Taxonomy%20for%20Robot%20Kinematic%20Calibration%20Methods&rft.jtitle=The%20International%20journal%20of%20robotics%20research&rft.au=Hollerbach,%20John%20M.&rft.date=1996-12-01&rft.volume=15&rft.issue=6&rft.spage=573&rft.epage=591&rft.pages=573-591&rft.issn=0278-3649&rft.eissn=1741-3176&rft.coden=IJRREL&rft_id=info:doi/10.1177/027836499601500604&rft_dat=%3Csage_cross%3E10.1177_027836499601500604%3C/sage_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c380t-c356f6259a32e71d81eefc863882b904c2afcda5e19ff57c26ad2e1240c240e53%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rft_sage_id=10.1177_027836499601500604&rfr_iscdi=true |