Plasma lignocaine concentrations following topical laryngeal application
Lignocaine 4%, 4 mg/kg, was sprayed onto the larynx and subglottic area of 96 children aged from 2 weeks to 12 years and plasma lignocaine concentrations were measured. While the majority were well within the accepted safe range (4.5 micrograms/ml) occasional concentrations over 8 micrograms/ml appe...
Saved in:
Published in: | Anaesthesia and intensive care 1983-02, Vol.11 (1), p.23-26 |
---|---|
Main Authors: | , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Lignocaine 4%, 4 mg/kg, was sprayed onto the larynx and subglottic area of 96 children aged from 2 weeks to 12 years and plasma lignocaine concentrations were measured. While the majority were well within the accepted safe range (4.5 micrograms/ml) occasional concentrations over 8 micrograms/ml appeared in all groups. Simultaneous arterial and venous sampling showed a small but significant difference in the first 10 minutes. |
---|---|
ISSN: | 0310-057X 1448-0271 |
DOI: | 10.1177/0310057x8301100105 |