Particularities of indoor atmospheric corrosion of steel inside electric boxes in the tropical climate of Tabasco, Mexico

Indoor corrosion inside electric boxes is important for the reliability of electric and electronic instruments. A parallel evaluation of indoor/outdoor atmospheric corrosion of steel, pollutants and meteorological parameters was made at two sites, i.e. a rural site and a coastal site of the Tabasco...

Full description

Saved in:
Bibliographic Details
Published in:Indoor + built environment 2021-12, Vol.30 (10), p.1609-1619
Main Authors: Angel-Meraz, Ebelia Del, Corvo, Francisco, Hernandez-Morales, Nancy E., Tejero-Rivas, Maria C.
Format: Article
Language:English
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c281t-95fc59db55cbe18df5257d681f02d0c69009991064c4806e0a6b53dc7d4ed8c73
cites cdi_FETCH-LOGICAL-c281t-95fc59db55cbe18df5257d681f02d0c69009991064c4806e0a6b53dc7d4ed8c73
container_end_page 1619
container_issue 10
container_start_page 1609
container_title Indoor + built environment
container_volume 30
creator Angel-Meraz, Ebelia Del
Corvo, Francisco
Hernandez-Morales, Nancy E.
Tejero-Rivas, Maria C.
description Indoor corrosion inside electric boxes is important for the reliability of electric and electronic instruments. A parallel evaluation of indoor/outdoor atmospheric corrosion of steel, pollutants and meteorological parameters was made at two sites, i.e. a rural site and a coastal site of the Tabasco State, Mexico. Two exposure conditions were evaluated: outdoors and inside electric boxes. Very low levels of sulphur compounds have been observed at the two exposure sites and two exposure conditions. As expected, corrosion of steel in an open atmosphere is higher than indoors (electric boxes). The difference between corrosion outdoors and inside electric boxes is higher at the coastal site due to the influence of chloride deposition. Significant differences have been observed in the morphology of corrosion products formed on steel. The influence of sun radiation, rain, dew and fog causes the formation of more compact corrosion products. The influence of Time of Wetness outdoors is in some extent equivalent to the influence of relative humidity inside electric boxes. Commonly, chloride deposition is very low indoors, showing low influence on corrosion. However, in particular conditions of Tabasco coastal tropical climate, its role is significant indoors. Reliability of electric and electronic instruments could be affected.
doi_str_mv 10.1177/1420326X20950411
format article
fullrecord <record><control><sourceid>sage_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1177_1420326X20950411</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sage_id>10.1177_1420326X20950411</sage_id><sourcerecordid>10.1177_1420326X20950411</sourcerecordid><originalsourceid>FETCH-LOGICAL-c281t-95fc59db55cbe18df5257d681f02d0c69009991064c4806e0a6b53dc7d4ed8c73</originalsourceid><addsrcrecordid>eNp1kE1PwzAMhiMEEmNw55gfQMFJm34c0cSXNASHIXGrUsdlmbqmSjJp-_e0jBMSJ1t-38eyX8auBdwKURR3IpOQyvxTQqUgE-KEzcZRmgAUcPrTQzLp5-wihA2AlFBkM3Z41z5a3HXa22gpcNdy2xvnPNdx68KwJm-Ro_PeBev6SQ-RqBtdwRri1BHGydK4_Yjbnsc18ejdYFF3HDu71ZEmbKUbHdDd8FfaW3SX7KzVXaCr3zpnH48Pq8Vzsnx7elncLxOUpYhJpVpUlWmUwoZEaVolVWHyUrQgDWBeAVRVJSDPMCshJ9B5o1KDhcnIlFikcwbHvTh-EDy19eDHm_yhFlBP0dV_oxuR5IgE_UX1xu18P174v_8bg_JwZw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Particularities of indoor atmospheric corrosion of steel inside electric boxes in the tropical climate of Tabasco, Mexico</title><source>SAGE:Jisc Collections:SAGE Journals Read and Publish 2023-2024:2025 extension (reading list)</source><creator>Angel-Meraz, Ebelia Del ; Corvo, Francisco ; Hernandez-Morales, Nancy E. ; Tejero-Rivas, Maria C.</creator><creatorcontrib>Angel-Meraz, Ebelia Del ; Corvo, Francisco ; Hernandez-Morales, Nancy E. ; Tejero-Rivas, Maria C.</creatorcontrib><description>Indoor corrosion inside electric boxes is important for the reliability of electric and electronic instruments. A parallel evaluation of indoor/outdoor atmospheric corrosion of steel, pollutants and meteorological parameters was made at two sites, i.e. a rural site and a coastal site of the Tabasco State, Mexico. Two exposure conditions were evaluated: outdoors and inside electric boxes. Very low levels of sulphur compounds have been observed at the two exposure sites and two exposure conditions. As expected, corrosion of steel in an open atmosphere is higher than indoors (electric boxes). The difference between corrosion outdoors and inside electric boxes is higher at the coastal site due to the influence of chloride deposition. Significant differences have been observed in the morphology of corrosion products formed on steel. The influence of sun radiation, rain, dew and fog causes the formation of more compact corrosion products. The influence of Time of Wetness outdoors is in some extent equivalent to the influence of relative humidity inside electric boxes. Commonly, chloride deposition is very low indoors, showing low influence on corrosion. However, in particular conditions of Tabasco coastal tropical climate, its role is significant indoors. Reliability of electric and electronic instruments could be affected.</description><identifier>ISSN: 1420-326X</identifier><identifier>EISSN: 1423-0070</identifier><identifier>DOI: 10.1177/1420326X20950411</identifier><language>eng</language><publisher>London, England: SAGE Publications</publisher><ispartof>Indoor + built environment, 2021-12, Vol.30 (10), p.1609-1619</ispartof><rights>The Author(s) 2020</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c281t-95fc59db55cbe18df5257d681f02d0c69009991064c4806e0a6b53dc7d4ed8c73</citedby><cites>FETCH-LOGICAL-c281t-95fc59db55cbe18df5257d681f02d0c69009991064c4806e0a6b53dc7d4ed8c73</cites><orcidid>0000-0001-7042-7382</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27901,27902</link.rule.ids></links><search><creatorcontrib>Angel-Meraz, Ebelia Del</creatorcontrib><creatorcontrib>Corvo, Francisco</creatorcontrib><creatorcontrib>Hernandez-Morales, Nancy E.</creatorcontrib><creatorcontrib>Tejero-Rivas, Maria C.</creatorcontrib><title>Particularities of indoor atmospheric corrosion of steel inside electric boxes in the tropical climate of Tabasco, Mexico</title><title>Indoor + built environment</title><description>Indoor corrosion inside electric boxes is important for the reliability of electric and electronic instruments. A parallel evaluation of indoor/outdoor atmospheric corrosion of steel, pollutants and meteorological parameters was made at two sites, i.e. a rural site and a coastal site of the Tabasco State, Mexico. Two exposure conditions were evaluated: outdoors and inside electric boxes. Very low levels of sulphur compounds have been observed at the two exposure sites and two exposure conditions. As expected, corrosion of steel in an open atmosphere is higher than indoors (electric boxes). The difference between corrosion outdoors and inside electric boxes is higher at the coastal site due to the influence of chloride deposition. Significant differences have been observed in the morphology of corrosion products formed on steel. The influence of sun radiation, rain, dew and fog causes the formation of more compact corrosion products. The influence of Time of Wetness outdoors is in some extent equivalent to the influence of relative humidity inside electric boxes. Commonly, chloride deposition is very low indoors, showing low influence on corrosion. However, in particular conditions of Tabasco coastal tropical climate, its role is significant indoors. Reliability of electric and electronic instruments could be affected.</description><issn>1420-326X</issn><issn>1423-0070</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2021</creationdate><recordtype>article</recordtype><recordid>eNp1kE1PwzAMhiMEEmNw55gfQMFJm34c0cSXNASHIXGrUsdlmbqmSjJp-_e0jBMSJ1t-38eyX8auBdwKURR3IpOQyvxTQqUgE-KEzcZRmgAUcPrTQzLp5-wihA2AlFBkM3Z41z5a3HXa22gpcNdy2xvnPNdx68KwJm-Ro_PeBev6SQ-RqBtdwRri1BHGydK4_Yjbnsc18ejdYFF3HDu71ZEmbKUbHdDd8FfaW3SX7KzVXaCr3zpnH48Pq8Vzsnx7elncLxOUpYhJpVpUlWmUwoZEaVolVWHyUrQgDWBeAVRVJSDPMCshJ9B5o1KDhcnIlFikcwbHvTh-EDy19eDHm_yhFlBP0dV_oxuR5IgE_UX1xu18P174v_8bg_JwZw</recordid><startdate>202112</startdate><enddate>202112</enddate><creator>Angel-Meraz, Ebelia Del</creator><creator>Corvo, Francisco</creator><creator>Hernandez-Morales, Nancy E.</creator><creator>Tejero-Rivas, Maria C.</creator><general>SAGE Publications</general><scope>AAYXX</scope><scope>CITATION</scope><orcidid>https://orcid.org/0000-0001-7042-7382</orcidid></search><sort><creationdate>202112</creationdate><title>Particularities of indoor atmospheric corrosion of steel inside electric boxes in the tropical climate of Tabasco, Mexico</title><author>Angel-Meraz, Ebelia Del ; Corvo, Francisco ; Hernandez-Morales, Nancy E. ; Tejero-Rivas, Maria C.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c281t-95fc59db55cbe18df5257d681f02d0c69009991064c4806e0a6b53dc7d4ed8c73</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2021</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Angel-Meraz, Ebelia Del</creatorcontrib><creatorcontrib>Corvo, Francisco</creatorcontrib><creatorcontrib>Hernandez-Morales, Nancy E.</creatorcontrib><creatorcontrib>Tejero-Rivas, Maria C.</creatorcontrib><collection>CrossRef</collection><jtitle>Indoor + built environment</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Angel-Meraz, Ebelia Del</au><au>Corvo, Francisco</au><au>Hernandez-Morales, Nancy E.</au><au>Tejero-Rivas, Maria C.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Particularities of indoor atmospheric corrosion of steel inside electric boxes in the tropical climate of Tabasco, Mexico</atitle><jtitle>Indoor + built environment</jtitle><date>2021-12</date><risdate>2021</risdate><volume>30</volume><issue>10</issue><spage>1609</spage><epage>1619</epage><pages>1609-1619</pages><issn>1420-326X</issn><eissn>1423-0070</eissn><abstract>Indoor corrosion inside electric boxes is important for the reliability of electric and electronic instruments. A parallel evaluation of indoor/outdoor atmospheric corrosion of steel, pollutants and meteorological parameters was made at two sites, i.e. a rural site and a coastal site of the Tabasco State, Mexico. Two exposure conditions were evaluated: outdoors and inside electric boxes. Very low levels of sulphur compounds have been observed at the two exposure sites and two exposure conditions. As expected, corrosion of steel in an open atmosphere is higher than indoors (electric boxes). The difference between corrosion outdoors and inside electric boxes is higher at the coastal site due to the influence of chloride deposition. Significant differences have been observed in the morphology of corrosion products formed on steel. The influence of sun radiation, rain, dew and fog causes the formation of more compact corrosion products. The influence of Time of Wetness outdoors is in some extent equivalent to the influence of relative humidity inside electric boxes. Commonly, chloride deposition is very low indoors, showing low influence on corrosion. However, in particular conditions of Tabasco coastal tropical climate, its role is significant indoors. Reliability of electric and electronic instruments could be affected.</abstract><cop>London, England</cop><pub>SAGE Publications</pub><doi>10.1177/1420326X20950411</doi><tpages>11</tpages><orcidid>https://orcid.org/0000-0001-7042-7382</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 1420-326X
ispartof Indoor + built environment, 2021-12, Vol.30 (10), p.1609-1619
issn 1420-326X
1423-0070
language eng
recordid cdi_crossref_primary_10_1177_1420326X20950411
source SAGE:Jisc Collections:SAGE Journals Read and Publish 2023-2024:2025 extension (reading list)
title Particularities of indoor atmospheric corrosion of steel inside electric boxes in the tropical climate of Tabasco, Mexico
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-05T21%3A27%3A59IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-sage_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Particularities%20of%20indoor%20atmospheric%20corrosion%20of%20steel%20inside%20electric%20boxes%20in%20the%20tropical%20climate%20of%20Tabasco,%20Mexico&rft.jtitle=Indoor%20+%20built%20environment&rft.au=Angel-Meraz,%20Ebelia%20Del&rft.date=2021-12&rft.volume=30&rft.issue=10&rft.spage=1609&rft.epage=1619&rft.pages=1609-1619&rft.issn=1420-326X&rft.eissn=1423-0070&rft_id=info:doi/10.1177/1420326X20950411&rft_dat=%3Csage_cross%3E10.1177_1420326X20950411%3C/sage_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c281t-95fc59db55cbe18df5257d681f02d0c69009991064c4806e0a6b53dc7d4ed8c73%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rft_sage_id=10.1177_1420326X20950411&rfr_iscdi=true