Impedance-based fault detection methodology for rotating machines
Visual examination, ultrasonic tests, and dye penetrant inspection are some examples of nondestructive techniques widely used for crack detection in rotors. These methods have proved to be costly, since satisfactory results rely on detailed and periodic inspections. Significant research effort has b...
Saved in:
Published in: | Structural health monitoring 2015-05, Vol.14 (3), p.228-240 |
---|---|
Main Authors: | , , |
Format: | Article |
Language: | English |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c281t-46e8196dcbb74e03e793291a80656fe4ea4bf1c8a69eccf445e07404f0e2cab03 |
---|---|
cites | cdi_FETCH-LOGICAL-c281t-46e8196dcbb74e03e793291a80656fe4ea4bf1c8a69eccf445e07404f0e2cab03 |
container_end_page | 240 |
container_issue | 3 |
container_start_page | 228 |
container_title | Structural health monitoring |
container_volume | 14 |
creator | Cavalini, Aldemir Ap Finzi Neto, Roberto Mendes Steffen, Valder |
description | Visual examination, ultrasonic tests, and dye penetrant inspection are some examples of nondestructive techniques widely used for crack detection in rotors. These methods have proved to be costly, since satisfactory results rely on detailed and periodic inspections. Significant research effort has been directed in recent years to online monitoring techniques, that is, based on vibration signals measured during rotor operation. However, most of them are able to only detect deep cracks. The uniqueness of this article relies on the possibility of detection of incipient transverse cracks in rotating shafts using the so-called, electromechanical impedance method. This method has become a promising tool for structural health monitoring of systems due to its sensitivity to small local damage. Basically, the method monitors changes in the electric impedance of piezoelectric transducers, bonded to (or embedded into) the host structure, through specific mathematic functions, the so-called damage metrics, to detect damage. This is possible because the electrical impedance of the transducer is directly related to the mechanical impedance of the structure. In this context, successful experimental tests were performed in a horizontal rotor supported by roller bearings. Lead zirconate titanate (PZT) patches were bonded along the shaft of the rotor in which saw cuts approximating a breathing transverse crack were machined. The technique was validated under different rotating speeds and unbalance conditions. |
doi_str_mv | 10.1177/1475921714564639 |
format | article |
fullrecord | <record><control><sourceid>sage_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1177_1475921714564639</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sage_id>10.1177_1475921714564639</sage_id><sourcerecordid>10.1177_1475921714564639</sourcerecordid><originalsourceid>FETCH-LOGICAL-c281t-46e8196dcbb74e03e793291a80656fe4ea4bf1c8a69eccf445e07404f0e2cab03</originalsourceid><addsrcrecordid>eNp1UD1rwzAUFKWFpmn3jvoDavXsZ8keQ-hHINClnY0sPzkOthUkZci_r0M6FTLdwX1wHGPPIF8AtH4F1EWVgQYsFKq8umEL0AgiB1XeznyWxVm_Zw8x7qWcqVYLttqMB2rNZEk0JlLLnTkOibeUyKbeT3yktPOtH3x34s4HHnwyqZ86Phq76yeKj-zOmSHS0x8u2c_72_f6U2y_Pjbr1VbYrIQkUFEJlWpt02gkmZOu8qwCU0pVKEdIBhsHtjSqImsdYkFSo0QnKbOmkfmSyUuvDT7GQK4-hH404VSDrM8X1P8vmCPiEommo3rvj2GaF173_wLE8Fwl</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Impedance-based fault detection methodology for rotating machines</title><source>Sage Journals Online</source><creator>Cavalini, Aldemir Ap ; Finzi Neto, Roberto Mendes ; Steffen, Valder</creator><creatorcontrib>Cavalini, Aldemir Ap ; Finzi Neto, Roberto Mendes ; Steffen, Valder</creatorcontrib><description>Visual examination, ultrasonic tests, and dye penetrant inspection are some examples of nondestructive techniques widely used for crack detection in rotors. These methods have proved to be costly, since satisfactory results rely on detailed and periodic inspections. Significant research effort has been directed in recent years to online monitoring techniques, that is, based on vibration signals measured during rotor operation. However, most of them are able to only detect deep cracks. The uniqueness of this article relies on the possibility of detection of incipient transverse cracks in rotating shafts using the so-called, electromechanical impedance method. This method has become a promising tool for structural health monitoring of systems due to its sensitivity to small local damage. Basically, the method monitors changes in the electric impedance of piezoelectric transducers, bonded to (or embedded into) the host structure, through specific mathematic functions, the so-called damage metrics, to detect damage. This is possible because the electrical impedance of the transducer is directly related to the mechanical impedance of the structure. In this context, successful experimental tests were performed in a horizontal rotor supported by roller bearings. Lead zirconate titanate (PZT) patches were bonded along the shaft of the rotor in which saw cuts approximating a breathing transverse crack were machined. The technique was validated under different rotating speeds and unbalance conditions.</description><identifier>ISSN: 1475-9217</identifier><identifier>EISSN: 1741-3168</identifier><identifier>DOI: 10.1177/1475921714564639</identifier><language>eng</language><publisher>London, England: SAGE Publications</publisher><ispartof>Structural health monitoring, 2015-05, Vol.14 (3), p.228-240</ispartof><rights>The Author(s) 2014</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c281t-46e8196dcbb74e03e793291a80656fe4ea4bf1c8a69eccf445e07404f0e2cab03</citedby><cites>FETCH-LOGICAL-c281t-46e8196dcbb74e03e793291a80656fe4ea4bf1c8a69eccf445e07404f0e2cab03</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925,79236</link.rule.ids></links><search><creatorcontrib>Cavalini, Aldemir Ap</creatorcontrib><creatorcontrib>Finzi Neto, Roberto Mendes</creatorcontrib><creatorcontrib>Steffen, Valder</creatorcontrib><title>Impedance-based fault detection methodology for rotating machines</title><title>Structural health monitoring</title><description>Visual examination, ultrasonic tests, and dye penetrant inspection are some examples of nondestructive techniques widely used for crack detection in rotors. These methods have proved to be costly, since satisfactory results rely on detailed and periodic inspections. Significant research effort has been directed in recent years to online monitoring techniques, that is, based on vibration signals measured during rotor operation. However, most of them are able to only detect deep cracks. The uniqueness of this article relies on the possibility of detection of incipient transverse cracks in rotating shafts using the so-called, electromechanical impedance method. This method has become a promising tool for structural health monitoring of systems due to its sensitivity to small local damage. Basically, the method monitors changes in the electric impedance of piezoelectric transducers, bonded to (or embedded into) the host structure, through specific mathematic functions, the so-called damage metrics, to detect damage. This is possible because the electrical impedance of the transducer is directly related to the mechanical impedance of the structure. In this context, successful experimental tests were performed in a horizontal rotor supported by roller bearings. Lead zirconate titanate (PZT) patches were bonded along the shaft of the rotor in which saw cuts approximating a breathing transverse crack were machined. The technique was validated under different rotating speeds and unbalance conditions.</description><issn>1475-9217</issn><issn>1741-3168</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2015</creationdate><recordtype>article</recordtype><recordid>eNp1UD1rwzAUFKWFpmn3jvoDavXsZ8keQ-hHINClnY0sPzkOthUkZci_r0M6FTLdwX1wHGPPIF8AtH4F1EWVgQYsFKq8umEL0AgiB1XeznyWxVm_Zw8x7qWcqVYLttqMB2rNZEk0JlLLnTkOibeUyKbeT3yktPOtH3x34s4HHnwyqZ86Phq76yeKj-zOmSHS0x8u2c_72_f6U2y_Pjbr1VbYrIQkUFEJlWpt02gkmZOu8qwCU0pVKEdIBhsHtjSqImsdYkFSo0QnKbOmkfmSyUuvDT7GQK4-hH404VSDrM8X1P8vmCPiEommo3rvj2GaF173_wLE8Fwl</recordid><startdate>20150501</startdate><enddate>20150501</enddate><creator>Cavalini, Aldemir Ap</creator><creator>Finzi Neto, Roberto Mendes</creator><creator>Steffen, Valder</creator><general>SAGE Publications</general><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>20150501</creationdate><title>Impedance-based fault detection methodology for rotating machines</title><author>Cavalini, Aldemir Ap ; Finzi Neto, Roberto Mendes ; Steffen, Valder</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c281t-46e8196dcbb74e03e793291a80656fe4ea4bf1c8a69eccf445e07404f0e2cab03</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2015</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Cavalini, Aldemir Ap</creatorcontrib><creatorcontrib>Finzi Neto, Roberto Mendes</creatorcontrib><creatorcontrib>Steffen, Valder</creatorcontrib><collection>CrossRef</collection><jtitle>Structural health monitoring</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Cavalini, Aldemir Ap</au><au>Finzi Neto, Roberto Mendes</au><au>Steffen, Valder</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Impedance-based fault detection methodology for rotating machines</atitle><jtitle>Structural health monitoring</jtitle><date>2015-05-01</date><risdate>2015</risdate><volume>14</volume><issue>3</issue><spage>228</spage><epage>240</epage><pages>228-240</pages><issn>1475-9217</issn><eissn>1741-3168</eissn><abstract>Visual examination, ultrasonic tests, and dye penetrant inspection are some examples of nondestructive techniques widely used for crack detection in rotors. These methods have proved to be costly, since satisfactory results rely on detailed and periodic inspections. Significant research effort has been directed in recent years to online monitoring techniques, that is, based on vibration signals measured during rotor operation. However, most of them are able to only detect deep cracks. The uniqueness of this article relies on the possibility of detection of incipient transverse cracks in rotating shafts using the so-called, electromechanical impedance method. This method has become a promising tool for structural health monitoring of systems due to its sensitivity to small local damage. Basically, the method monitors changes in the electric impedance of piezoelectric transducers, bonded to (or embedded into) the host structure, through specific mathematic functions, the so-called damage metrics, to detect damage. This is possible because the electrical impedance of the transducer is directly related to the mechanical impedance of the structure. In this context, successful experimental tests were performed in a horizontal rotor supported by roller bearings. Lead zirconate titanate (PZT) patches were bonded along the shaft of the rotor in which saw cuts approximating a breathing transverse crack were machined. The technique was validated under different rotating speeds and unbalance conditions.</abstract><cop>London, England</cop><pub>SAGE Publications</pub><doi>10.1177/1475921714564639</doi><tpages>13</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1475-9217 |
ispartof | Structural health monitoring, 2015-05, Vol.14 (3), p.228-240 |
issn | 1475-9217 1741-3168 |
language | eng |
recordid | cdi_crossref_primary_10_1177_1475921714564639 |
source | Sage Journals Online |
title | Impedance-based fault detection methodology for rotating machines |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-07T19%3A13%3A51IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-sage_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Impedance-based%20fault%20detection%20methodology%20for%20rotating%20machines&rft.jtitle=Structural%20health%20monitoring&rft.au=Cavalini,%20Aldemir%20Ap&rft.date=2015-05-01&rft.volume=14&rft.issue=3&rft.spage=228&rft.epage=240&rft.pages=228-240&rft.issn=1475-9217&rft.eissn=1741-3168&rft_id=info:doi/10.1177/1475921714564639&rft_dat=%3Csage_cross%3E10.1177_1475921714564639%3C/sage_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c281t-46e8196dcbb74e03e793291a80656fe4ea4bf1c8a69eccf445e07404f0e2cab03%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rft_sage_id=10.1177_1475921714564639&rfr_iscdi=true |