Loading…

Evaluation of an EEG/Electro-dermal Hybrid Device to Ascertain a User’s Attentional State

The purpose of this study was to evaluate an alleged EEG amplifier’s, the Freer Logic BodyWave, ability to record EEG by comparing its signals to those recorded at the same time by a proven EEG amplifier, the Emotiv EPOC+. The BodyWave’s circuitry is similar to that of an Electro-dermal Activity met...

Full description

Saved in:
Bibliographic Details
Published in:Proceedings of the Human Factors and Ergonomics Society Annual Meeting 2016-09, Vol.60 (1), p.26-30
Main Authors: Davies, Simon R.H., Mistry, Urmila, Millen, Laura, Skrypchuk, Lee, Braithwaite, Jim
Format: Article
Language:English
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c244t-5fa33d8ae5dcc276c93e09e7fabc5503e6d5e0357a8f988dcbb8ad9deefaec0b3
cites cdi_FETCH-LOGICAL-c244t-5fa33d8ae5dcc276c93e09e7fabc5503e6d5e0357a8f988dcbb8ad9deefaec0b3
container_end_page 30
container_issue 1
container_start_page 26
container_title Proceedings of the Human Factors and Ergonomics Society Annual Meeting
container_volume 60
creator Davies, Simon R.H.
Mistry, Urmila
Millen, Laura
Skrypchuk, Lee
Braithwaite, Jim
description The purpose of this study was to evaluate an alleged EEG amplifier’s, the Freer Logic BodyWave, ability to record EEG by comparing its signals to those recorded at the same time by a proven EEG amplifier, the Emotiv EPOC+. The BodyWave’s circuitry is similar to that of an Electro-dermal Activity meter and alleges to record surface-EEG from a limb of the user. The EPOC+ has been proven in previous studies to record signals of high-enough quality to be used in research, whilst the BodyWave is unproven. In order to compare their recordings, both EEGs were worn simultaneously whilst different stimuli induced various brain states. 15 participants were recruited and each subjected to two different experimental paradigms meant to induce increased attention and increased relaxation. Both headsets achieved a classification accuracy well above chance when differentiating between the attention and relaxation tasks. Further testing provided evidence that data from the alpha and beta frequency bands was contributing the most to the classifier’s accuracy. However the total lack of correlation between the signals of the two devices strongly implies that the BodyWave is not measuring EEG. Despite this these results show that in some cases it can be used in place of an EEG to perform a similar function. It also proved to be much more robust against muscle artefacts compared to the EPOC+.
doi_str_mv 10.1177/1541931213601006
format article
fullrecord <record><control><sourceid>sage_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1177_1541931213601006</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sage_id>10.1177_1541931213601006</sage_id><sourcerecordid>10.1177_1541931213601006</sourcerecordid><originalsourceid>FETCH-LOGICAL-c244t-5fa33d8ae5dcc276c93e09e7fabc5503e6d5e0357a8f988dcbb8ad9deefaec0b3</originalsourceid><addsrcrecordid>eNp1kLFOwzAYhC0EEqWwM_oFQn_HcZyMVQktUiUG6MQQ_bF_o1Rpgmy3Ujdeg9fjSWhVBoTEdDfcdzodY7cC7oTQeiJUJkopUiFzEAD5GRulIi8TBbk-_-Uv2VUIa4BUapmN2Gu1w26LsR16PjiOPa-q-aTqyEQ_JJb8Bju-2De-tfyedq0hHgc-DYZ8xLbnyFeB_NfHZ-DTGKk_Fh2I54iRrtmFwy7QzY-O2eqhepktkuXT_HE2XSYmzbKYKIdS2gJJWWNSnZtSEpSkHTZGKZCUW0UglcbClUVhTdMUaEtL5JAMNHLM4NRr_BCCJ1e_-3aDfl8LqI_n1H_POSDJCQn4RvV62PrD6vB__htQNmYv</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Evaluation of an EEG/Electro-dermal Hybrid Device to Ascertain a User’s Attentional State</title><source>SAGE:Jisc Collections:SAGE Journals Read and Publish 2023-2024:2025 extension (reading list)</source><creator>Davies, Simon R.H. ; Mistry, Urmila ; Millen, Laura ; Skrypchuk, Lee ; Braithwaite, Jim</creator><creatorcontrib>Davies, Simon R.H. ; Mistry, Urmila ; Millen, Laura ; Skrypchuk, Lee ; Braithwaite, Jim</creatorcontrib><description>The purpose of this study was to evaluate an alleged EEG amplifier’s, the Freer Logic BodyWave, ability to record EEG by comparing its signals to those recorded at the same time by a proven EEG amplifier, the Emotiv EPOC+. The BodyWave’s circuitry is similar to that of an Electro-dermal Activity meter and alleges to record surface-EEG from a limb of the user. The EPOC+ has been proven in previous studies to record signals of high-enough quality to be used in research, whilst the BodyWave is unproven. In order to compare their recordings, both EEGs were worn simultaneously whilst different stimuli induced various brain states. 15 participants were recruited and each subjected to two different experimental paradigms meant to induce increased attention and increased relaxation. Both headsets achieved a classification accuracy well above chance when differentiating between the attention and relaxation tasks. Further testing provided evidence that data from the alpha and beta frequency bands was contributing the most to the classifier’s accuracy. However the total lack of correlation between the signals of the two devices strongly implies that the BodyWave is not measuring EEG. Despite this these results show that in some cases it can be used in place of an EEG to perform a similar function. It also proved to be much more robust against muscle artefacts compared to the EPOC+.</description><identifier>ISSN: 2169-5067</identifier><identifier>ISSN: 1071-1813</identifier><identifier>EISSN: 2169-5067</identifier><identifier>DOI: 10.1177/1541931213601006</identifier><language>eng</language><publisher>Los Angeles, CA: SAGE Publications</publisher><ispartof>Proceedings of the Human Factors and Ergonomics Society Annual Meeting, 2016-09, Vol.60 (1), p.26-30</ispartof><rights>2016 Human Factors and Ergonomics Society</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c244t-5fa33d8ae5dcc276c93e09e7fabc5503e6d5e0357a8f988dcbb8ad9deefaec0b3</citedby><cites>FETCH-LOGICAL-c244t-5fa33d8ae5dcc276c93e09e7fabc5503e6d5e0357a8f988dcbb8ad9deefaec0b3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27901,27902</link.rule.ids></links><search><creatorcontrib>Davies, Simon R.H.</creatorcontrib><creatorcontrib>Mistry, Urmila</creatorcontrib><creatorcontrib>Millen, Laura</creatorcontrib><creatorcontrib>Skrypchuk, Lee</creatorcontrib><creatorcontrib>Braithwaite, Jim</creatorcontrib><title>Evaluation of an EEG/Electro-dermal Hybrid Device to Ascertain a User’s Attentional State</title><title>Proceedings of the Human Factors and Ergonomics Society Annual Meeting</title><description>The purpose of this study was to evaluate an alleged EEG amplifier’s, the Freer Logic BodyWave, ability to record EEG by comparing its signals to those recorded at the same time by a proven EEG amplifier, the Emotiv EPOC+. The BodyWave’s circuitry is similar to that of an Electro-dermal Activity meter and alleges to record surface-EEG from a limb of the user. The EPOC+ has been proven in previous studies to record signals of high-enough quality to be used in research, whilst the BodyWave is unproven. In order to compare their recordings, both EEGs were worn simultaneously whilst different stimuli induced various brain states. 15 participants were recruited and each subjected to two different experimental paradigms meant to induce increased attention and increased relaxation. Both headsets achieved a classification accuracy well above chance when differentiating between the attention and relaxation tasks. Further testing provided evidence that data from the alpha and beta frequency bands was contributing the most to the classifier’s accuracy. However the total lack of correlation between the signals of the two devices strongly implies that the BodyWave is not measuring EEG. Despite this these results show that in some cases it can be used in place of an EEG to perform a similar function. It also proved to be much more robust against muscle artefacts compared to the EPOC+.</description><issn>2169-5067</issn><issn>1071-1813</issn><issn>2169-5067</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2016</creationdate><recordtype>article</recordtype><recordid>eNp1kLFOwzAYhC0EEqWwM_oFQn_HcZyMVQktUiUG6MQQ_bF_o1Rpgmy3Ujdeg9fjSWhVBoTEdDfcdzodY7cC7oTQeiJUJkopUiFzEAD5GRulIi8TBbk-_-Uv2VUIa4BUapmN2Gu1w26LsR16PjiOPa-q-aTqyEQ_JJb8Bju-2De-tfyedq0hHgc-DYZ8xLbnyFeB_NfHZ-DTGKk_Fh2I54iRrtmFwy7QzY-O2eqhepktkuXT_HE2XSYmzbKYKIdS2gJJWWNSnZtSEpSkHTZGKZCUW0UglcbClUVhTdMUaEtL5JAMNHLM4NRr_BCCJ1e_-3aDfl8LqI_n1H_POSDJCQn4RvV62PrD6vB__htQNmYv</recordid><startdate>201609</startdate><enddate>201609</enddate><creator>Davies, Simon R.H.</creator><creator>Mistry, Urmila</creator><creator>Millen, Laura</creator><creator>Skrypchuk, Lee</creator><creator>Braithwaite, Jim</creator><general>SAGE Publications</general><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>201609</creationdate><title>Evaluation of an EEG/Electro-dermal Hybrid Device to Ascertain a User’s Attentional State</title><author>Davies, Simon R.H. ; Mistry, Urmila ; Millen, Laura ; Skrypchuk, Lee ; Braithwaite, Jim</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c244t-5fa33d8ae5dcc276c93e09e7fabc5503e6d5e0357a8f988dcbb8ad9deefaec0b3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2016</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Davies, Simon R.H.</creatorcontrib><creatorcontrib>Mistry, Urmila</creatorcontrib><creatorcontrib>Millen, Laura</creatorcontrib><creatorcontrib>Skrypchuk, Lee</creatorcontrib><creatorcontrib>Braithwaite, Jim</creatorcontrib><collection>CrossRef</collection><jtitle>Proceedings of the Human Factors and Ergonomics Society Annual Meeting</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Davies, Simon R.H.</au><au>Mistry, Urmila</au><au>Millen, Laura</au><au>Skrypchuk, Lee</au><au>Braithwaite, Jim</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Evaluation of an EEG/Electro-dermal Hybrid Device to Ascertain a User’s Attentional State</atitle><jtitle>Proceedings of the Human Factors and Ergonomics Society Annual Meeting</jtitle><date>2016-09</date><risdate>2016</risdate><volume>60</volume><issue>1</issue><spage>26</spage><epage>30</epage><pages>26-30</pages><issn>2169-5067</issn><issn>1071-1813</issn><eissn>2169-5067</eissn><abstract>The purpose of this study was to evaluate an alleged EEG amplifier’s, the Freer Logic BodyWave, ability to record EEG by comparing its signals to those recorded at the same time by a proven EEG amplifier, the Emotiv EPOC+. The BodyWave’s circuitry is similar to that of an Electro-dermal Activity meter and alleges to record surface-EEG from a limb of the user. The EPOC+ has been proven in previous studies to record signals of high-enough quality to be used in research, whilst the BodyWave is unproven. In order to compare their recordings, both EEGs were worn simultaneously whilst different stimuli induced various brain states. 15 participants were recruited and each subjected to two different experimental paradigms meant to induce increased attention and increased relaxation. Both headsets achieved a classification accuracy well above chance when differentiating between the attention and relaxation tasks. Further testing provided evidence that data from the alpha and beta frequency bands was contributing the most to the classifier’s accuracy. However the total lack of correlation between the signals of the two devices strongly implies that the BodyWave is not measuring EEG. Despite this these results show that in some cases it can be used in place of an EEG to perform a similar function. It also proved to be much more robust against muscle artefacts compared to the EPOC+.</abstract><cop>Los Angeles, CA</cop><pub>SAGE Publications</pub><doi>10.1177/1541931213601006</doi><tpages>5</tpages></addata></record>
fulltext fulltext
identifier ISSN: 2169-5067
ispartof Proceedings of the Human Factors and Ergonomics Society Annual Meeting, 2016-09, Vol.60 (1), p.26-30
issn 2169-5067
1071-1813
2169-5067
language eng
recordid cdi_crossref_primary_10_1177_1541931213601006
source SAGE:Jisc Collections:SAGE Journals Read and Publish 2023-2024:2025 extension (reading list)
title Evaluation of an EEG/Electro-dermal Hybrid Device to Ascertain a User’s Attentional State
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-30T07%3A11%3A03IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-sage_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Evaluation%20of%20an%20EEG/Electro-dermal%20Hybrid%20Device%20to%20Ascertain%20a%20User%E2%80%99s%20Attentional%20State&rft.jtitle=Proceedings%20of%20the%20Human%20Factors%20and%20Ergonomics%20Society%20Annual%20Meeting&rft.au=Davies,%20Simon%20R.H.&rft.date=2016-09&rft.volume=60&rft.issue=1&rft.spage=26&rft.epage=30&rft.pages=26-30&rft.issn=2169-5067&rft.eissn=2169-5067&rft_id=info:doi/10.1177/1541931213601006&rft_dat=%3Csage_cross%3E10.1177_1541931213601006%3C/sage_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c244t-5fa33d8ae5dcc276c93e09e7fabc5503e6d5e0357a8f988dcbb8ad9deefaec0b3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rft_sage_id=10.1177_1541931213601006&rfr_iscdi=true