Robotic Transthoracic Primary Repair of a Diaphragmatic Hernia and Reduction of an Intrathoracic Liver
This case involves a 70-year-old woman who presented after a low-speed motor vehicle collision with a traumatic right hemidiaphragm rupture and herniation of the liver into the right chest. She was brought to the operating room for a robotic-assisted minimally invasive transthoracic repair of this h...
Saved in:
Published in: | Innovations (Philadelphia, Pa.) Pa.), 2018-01, Vol.13 (1), p.54-55 |
---|---|
Main Authors: | , , , |
Format: | Article |
Language: | English |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | This case involves a 70-year-old woman who presented after a low-speed motor vehicle collision with a traumatic right hemidiaphragm rupture and herniation of the liver into the right chest. She was brought to the operating room for a robotic-assisted minimally invasive transthoracic repair of this hernia with diaphragm plication. The case and video described in this report highlight the utility of the robotic platform in performing a transthoracic diaphragm repair and plication after a right-sided traumatic diaphragm rupture in a patient without concomitant abdominal injuries. |
---|---|