Simplified Methodology for Calculating Dump Tank Volumes
Dump tanks are used as an initial treatment to separate the liquid and gas phases of the discharge from the emergency relief of a runaway chemical reactor. Methods are developed for sizing such vessels for vapour pressure, ’gassy’ and hybrid systems, requiring iterative solution. A simplified method...
Saved in:
Published in: | Chemical engineering research & design 2000, Vol.78 (3), p.473-480 |
---|---|
Main Authors: | , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Dump tanks are used as an initial treatment to separate the liquid and gas phases of the discharge from the emergency relief of a runaway chemical reactor. Methods are developed for sizing such vessels for vapour pressure, ’gassy’ and hybrid systems, requiring iterative solution. A simplified methodology is given, eliminating the need for iteration at the expense of a small error. Analysis allows evaluation of the maximum error and accurate prediction of the actual error involved in each specific case. Examples of sizing methods are given for vapour pressure and ‘gassy’ systems. |
---|---|