Loading…
Simultaneous measurement of OH radical, H 2 O concentration, and temperature in a premixed CH 4 /air flame using TDLAS with an improved analysis method
The OH radical concentration was measured by applying tunable diode laser absorption spectroscopy, which is an in situ optical method. An optical absorption region (P7.5ff transition at 1502.7 nm) of the OH radical was selected in the near-infrared range to measure the OH radicals quantitatively in...
Saved in:
Published in: | Optics express 2022-08, Vol.30 (18), p.32031 |
---|---|
Main Authors: | , , , , , |
Format: | Article |
Language: | English |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | The OH radical concentration was measured by applying tunable diode laser absorption spectroscopy, which is an in situ optical method. An optical absorption region (P7.5ff transition at 1502.7 nm) of the OH radical was selected in the near-infrared range to measure the OH radicals quantitatively in premixed CH 4 /air flames. An improved direct absorption spectroscopy (DAS) method based on wavelength division multiplexing was proposed to extract the H 2 O absorption signal that interfered with the OH light absorption signal, and the integral intensity of OH* chemiluminescence was compared to the measured OH radical concentration based on the improved DAS method. |
---|---|
ISSN: | 1094-4087 1094-4087 |
DOI: | 10.1364/OE.466138 |