Aortic regurgitation after transcatheter aortic valve replacement: Influence of valve prosthesis implantation depth inside the aortic annulus on paravalvular regurgitation in in vitro steady flow conditions

The assessment of hydrodynamic performance of transcatheter aortic valve prostheses in vitro is essential for the develosepment and approval of novel devices. Therefore, this study aims to investigate the correlation of target implantation depth and paravalvular regurgitation in a controlled in vitr...

Full description

Saved in:
Bibliographic Details
Published in:Current directions in biomedical engineering 2018-09, Vol.4 (1), p.195-198
Format: Article
Language:English
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by
cites
container_end_page 198
container_issue 1
container_start_page 195
container_title Current directions in biomedical engineering
container_volume 4
description The assessment of hydrodynamic performance of transcatheter aortic valve prostheses in vitro is essential for the develosepment and approval of novel devices. Therefore, this study aims to investigate the correlation of target implantation depth and paravalvular regurgitation in a controlled in vitro test situation. We designed a test setup with retrograde steady flow conditions measuring paravalvular regurgitation as a function of increasing pressure on the closed valve ranging from 0 mmHg to 200 mmHg. Our future aim is to benchmark different valve prosthesis designs and describe the correlation between target implantation depth, paravalvular regurgitation and prosthesis design aspects. The current study describes the developed test setup, validation experiments as well as first results for a selfexpanding valve prosthesis. The highest regurgitation was measured at an implantation depth of 2 mm. In fact, regurgitation increases from 26.1 ± 8.2 ml/min at 0 mmHg to 1,490.7 ± 182.7 ml/min at 160 mmHg. The slightest regurgitation, however, was measured for an implantation depth of 6 mm ranging from 2.2 ± 0.6 ml/min at 0 mmHg to 605.8 ± 18.9 ml/min at 200 mmHg.
doi_str_mv 10.1515/cdbme-2018-0048
format article
fullrecord <record><control><sourceid>crossref</sourceid><recordid>TN_cdi_crossref_primary_10_1515_cdbme_2018_0048</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>10_1515_cdbme_2018_0048</sourcerecordid><originalsourceid>FETCH-LOGICAL-c147t-d0ed17308ae3973b03938e5a0b9cee49f3d71ac60026c4dc882312a82b00d4493</originalsourceid><addsrcrecordid>eNpNkEtLxDAUhYMoOIyzdts_EOfm0TRdlsEXDLjRdbhNbsdKH0MSB_z3WseFq3MOfJzFx9itgDtRinLrQzsSlyAsB9D2gq2kMpqXJejLf_2abVL6AABhpDFWrVjTzDH3voh0-IyHPmPu56nALlMscsQpeczvtCw8gyccTvSDHwf0NNKUb9hVh0OizV-u2dvD_evuie9fHp93zZ57oavMA1AQlQKLpOpKtaBqZalEaGtPpOtOhUqgNwDSeB28tVIJiVa2AEHrWq3Z9vzr45xSpM4dYz9i_HIC3CLB_UpwiwS3SFDfzy9Q8A</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Aortic regurgitation after transcatheter aortic valve replacement: Influence of valve prosthesis implantation depth inside the aortic annulus on paravalvular regurgitation in in vitro steady flow conditions</title><source>De Gruyter Open Access Journals</source><description>The assessment of hydrodynamic performance of transcatheter aortic valve prostheses in vitro is essential for the develosepment and approval of novel devices. Therefore, this study aims to investigate the correlation of target implantation depth and paravalvular regurgitation in a controlled in vitro test situation. We designed a test setup with retrograde steady flow conditions measuring paravalvular regurgitation as a function of increasing pressure on the closed valve ranging from 0 mmHg to 200 mmHg. Our future aim is to benchmark different valve prosthesis designs and describe the correlation between target implantation depth, paravalvular regurgitation and prosthesis design aspects. The current study describes the developed test setup, validation experiments as well as first results for a selfexpanding valve prosthesis. The highest regurgitation was measured at an implantation depth of 2 mm. In fact, regurgitation increases from 26.1 ± 8.2 ml/min at 0 mmHg to 1,490.7 ± 182.7 ml/min at 160 mmHg. The slightest regurgitation, however, was measured for an implantation depth of 6 mm ranging from 2.2 ± 0.6 ml/min at 0 mmHg to 605.8 ± 18.9 ml/min at 200 mmHg.</description><identifier>ISSN: 2364-5504</identifier><identifier>EISSN: 2364-5504</identifier><identifier>DOI: 10.1515/cdbme-2018-0048</identifier><language>eng</language><ispartof>Current directions in biomedical engineering, 2018-09, Vol.4 (1), p.195-198</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,777,781,27905,27906</link.rule.ids></links><search><title>Aortic regurgitation after transcatheter aortic valve replacement: Influence of valve prosthesis implantation depth inside the aortic annulus on paravalvular regurgitation in in vitro steady flow conditions</title><title>Current directions in biomedical engineering</title><description>The assessment of hydrodynamic performance of transcatheter aortic valve prostheses in vitro is essential for the develosepment and approval of novel devices. Therefore, this study aims to investigate the correlation of target implantation depth and paravalvular regurgitation in a controlled in vitro test situation. We designed a test setup with retrograde steady flow conditions measuring paravalvular regurgitation as a function of increasing pressure on the closed valve ranging from 0 mmHg to 200 mmHg. Our future aim is to benchmark different valve prosthesis designs and describe the correlation between target implantation depth, paravalvular regurgitation and prosthesis design aspects. The current study describes the developed test setup, validation experiments as well as first results for a selfexpanding valve prosthesis. The highest regurgitation was measured at an implantation depth of 2 mm. In fact, regurgitation increases from 26.1 ± 8.2 ml/min at 0 mmHg to 1,490.7 ± 182.7 ml/min at 160 mmHg. The slightest regurgitation, however, was measured for an implantation depth of 6 mm ranging from 2.2 ± 0.6 ml/min at 0 mmHg to 605.8 ± 18.9 ml/min at 200 mmHg.</description><issn>2364-5504</issn><issn>2364-5504</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2018</creationdate><recordtype>article</recordtype><recordid>eNpNkEtLxDAUhYMoOIyzdts_EOfm0TRdlsEXDLjRdbhNbsdKH0MSB_z3WseFq3MOfJzFx9itgDtRinLrQzsSlyAsB9D2gq2kMpqXJejLf_2abVL6AABhpDFWrVjTzDH3voh0-IyHPmPu56nALlMscsQpeczvtCw8gyccTvSDHwf0NNKUb9hVh0OizV-u2dvD_evuie9fHp93zZ57oavMA1AQlQKLpOpKtaBqZalEaGtPpOtOhUqgNwDSeB28tVIJiVa2AEHrWq3Z9vzr45xSpM4dYz9i_HIC3CLB_UpwiwS3SFDfzy9Q8A</recordid><startdate>20180901</startdate><enddate>20180901</enddate><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>20180901</creationdate><title>Aortic regurgitation after transcatheter aortic valve replacement</title></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c147t-d0ed17308ae3973b03938e5a0b9cee49f3d71ac60026c4dc882312a82b00d4493</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2018</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><collection>CrossRef</collection><jtitle>Current directions in biomedical engineering</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Aortic regurgitation after transcatheter aortic valve replacement: Influence of valve prosthesis implantation depth inside the aortic annulus on paravalvular regurgitation in in vitro steady flow conditions</atitle><jtitle>Current directions in biomedical engineering</jtitle><date>2018-09-01</date><risdate>2018</risdate><volume>4</volume><issue>1</issue><spage>195</spage><epage>198</epage><pages>195-198</pages><issn>2364-5504</issn><eissn>2364-5504</eissn><abstract>The assessment of hydrodynamic performance of transcatheter aortic valve prostheses in vitro is essential for the develosepment and approval of novel devices. Therefore, this study aims to investigate the correlation of target implantation depth and paravalvular regurgitation in a controlled in vitro test situation. We designed a test setup with retrograde steady flow conditions measuring paravalvular regurgitation as a function of increasing pressure on the closed valve ranging from 0 mmHg to 200 mmHg. Our future aim is to benchmark different valve prosthesis designs and describe the correlation between target implantation depth, paravalvular regurgitation and prosthesis design aspects. The current study describes the developed test setup, validation experiments as well as first results for a selfexpanding valve prosthesis. The highest regurgitation was measured at an implantation depth of 2 mm. In fact, regurgitation increases from 26.1 ± 8.2 ml/min at 0 mmHg to 1,490.7 ± 182.7 ml/min at 160 mmHg. The slightest regurgitation, however, was measured for an implantation depth of 6 mm ranging from 2.2 ± 0.6 ml/min at 0 mmHg to 605.8 ± 18.9 ml/min at 200 mmHg.</abstract><doi>10.1515/cdbme-2018-0048</doi><tpages>4</tpages></addata></record>
fulltext fulltext
identifier ISSN: 2364-5504
ispartof Current directions in biomedical engineering, 2018-09, Vol.4 (1), p.195-198
issn 2364-5504
2364-5504
language eng
recordid cdi_crossref_primary_10_1515_cdbme_2018_0048
source De Gruyter Open Access Journals
title Aortic regurgitation after transcatheter aortic valve replacement: Influence of valve prosthesis implantation depth inside the aortic annulus on paravalvular regurgitation in in vitro steady flow conditions
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-19T09%3A23%3A00IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-crossref&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Aortic%20regurgitation%20after%20transcatheter%20aortic%20valve%20replacement:%20Influence%20of%20valve%20prosthesis%20implantation%20depth%20inside%20the%20aortic%20annulus%20on%20paravalvular%20regurgitation%20in%20in%20vitro%20steady%20flow%20conditions&rft.jtitle=Current%20directions%20in%20biomedical%20engineering&rft.date=2018-09-01&rft.volume=4&rft.issue=1&rft.spage=195&rft.epage=198&rft.pages=195-198&rft.issn=2364-5504&rft.eissn=2364-5504&rft_id=info:doi/10.1515/cdbme-2018-0048&rft_dat=%3Ccrossref%3E10_1515_cdbme_2018_0048%3C/crossref%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c147t-d0ed17308ae3973b03938e5a0b9cee49f3d71ac60026c4dc882312a82b00d4493%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true