Loading…
Considerations on the Experimental Calibration of the Fall Cone Test
The fall cone test is widely used in soil mechanics to determine the liquid limit of fine-grained soils as an aid to soil classification. The test can also be used to obtain the undrained shear strength of a fine-grained soil, based on the “cone factor,” K. Reports from different authors show K valu...
Saved in:
Published in: | Geotechnical testing journal 2018-11, Vol.41 (6), p.1131-1138 |
---|---|
Main Authors: | , , , , |
Format: | Article |
Language: | English |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-a494t-272df2b6071e8f66e8e87df8aacdbdba29b846553b652540217d4955831ec2773 |
---|---|
cites | cdi_FETCH-LOGICAL-a494t-272df2b6071e8f66e8e87df8aacdbdba29b846553b652540217d4955831ec2773 |
container_end_page | 1138 |
container_issue | 6 |
container_start_page | 1131 |
container_title | Geotechnical testing journal |
container_volume | 41 |
creator | Llano-Serna, Marcelo A. Farias, Márcio M. Pedroso, Dorival M. Williams, David J. Sheng, Daichao |
description | The fall cone test is widely used in soil mechanics to determine the liquid limit of fine-grained soils as an aid to soil classification. The test can also be used to obtain the undrained shear strength of a fine-grained soil, based on the “cone factor,” K. Reports from different authors show K values ranging from 0.4–1.33. Differences are mostly attributed to the cone surface roughness. This article presents a reinterpretation of several experimental observations available in the literature. It is observed that besides the cone roughness, testing methods have a clear influence when calibrating the fall cone for determining the undrained shear strength of materials with low and very low consistency. The results show that existing K reports should be extrapolated with care. Finally, we propose a series of recommendations and good practices for future calibrations. |
doi_str_mv | 10.1520/GTJ20170205 |
format | article |
fullrecord | <record><control><sourceid>astm_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1520_GTJ20170205</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>10_1520_GTJ20170205</sourcerecordid><originalsourceid>FETCH-LOGICAL-a494t-272df2b6071e8f66e8e87df8aacdbdba29b846553b652540217d4955831ec2773</originalsourceid><addsrcrecordid>eNqlkM1KxDAURoMoWEdXvkCXglRz0_x1p9SZURlwU9chbRLs0GlLU0F9ejPWhYuBEV3dcPPl5PAhdA74ChjB18vikWAQmGB2gCLIKEsEo-wQRRholnAAdoxOvF9jDJIIEqG7vGt9beygxzqc4q6Nxxcbz996O9Qb2466iXPd1OUUiDv3db_QTdh3rY0L68dTdOR04-3Z95yh58W8yO-T1dPyIb9dJZpmdEzCh8aRkmMBVjrOrbRSGCe1rkxpSk2yUlLOWFpyRhjFBIShGWMyBVsRIdIZupy41dB5P1in-iCph3cFWG0LUD8KCOmbKa39uFHr7nVog9w2oigorgCCiFQfdb_rueqN-w1C7kVc7EL8RRgLQv8tDGQP4hP2kqhD</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Considerations on the Experimental Calibration of the Fall Cone Test</title><source>ASTM Journals</source><creator>Llano-Serna, Marcelo A. ; Farias, Márcio M. ; Pedroso, Dorival M. ; Williams, David J. ; Sheng, Daichao</creator><contributor>Suits, L. David</contributor><creatorcontrib>Llano-Serna, Marcelo A. ; Farias, Márcio M. ; Pedroso, Dorival M. ; Williams, David J. ; Sheng, Daichao ; Suits, L. David</creatorcontrib><description>The fall cone test is widely used in soil mechanics to determine the liquid limit of fine-grained soils as an aid to soil classification. The test can also be used to obtain the undrained shear strength of a fine-grained soil, based on the “cone factor,” K. Reports from different authors show K values ranging from 0.4–1.33. Differences are mostly attributed to the cone surface roughness. This article presents a reinterpretation of several experimental observations available in the literature. It is observed that besides the cone roughness, testing methods have a clear influence when calibrating the fall cone for determining the undrained shear strength of materials with low and very low consistency. The results show that existing K reports should be extrapolated with care. Finally, we propose a series of recommendations and good practices for future calibrations.</description><identifier>ISSN: 0149-6115</identifier><identifier>EISSN: 1945-7545</identifier><identifier>DOI: 10.1520/GTJ20170205</identifier><identifier>CODEN: GTJODJ</identifier><language>eng</language><ispartof>Geotechnical testing journal, 2018-11, Vol.41 (6), p.1131-1138</ispartof><rights>All rights reserved. This material may not be reproduced or copied, in whole or part, in any printed, mechanical, electronic, film, or other distribution and storage media, without the written consent of the publisher.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-a494t-272df2b6071e8f66e8e87df8aacdbdba29b846553b652540217d4955831ec2773</citedby><cites>FETCH-LOGICAL-a494t-272df2b6071e8f66e8e87df8aacdbdba29b846553b652540217d4955831ec2773</cites><orcidid>0000-0002-4395-8636</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,9791,27924,27925</link.rule.ids></links><search><contributor>Suits, L. David</contributor><creatorcontrib>Llano-Serna, Marcelo A.</creatorcontrib><creatorcontrib>Farias, Márcio M.</creatorcontrib><creatorcontrib>Pedroso, Dorival M.</creatorcontrib><creatorcontrib>Williams, David J.</creatorcontrib><creatorcontrib>Sheng, Daichao</creatorcontrib><title>Considerations on the Experimental Calibration of the Fall Cone Test</title><title>Geotechnical testing journal</title><description>The fall cone test is widely used in soil mechanics to determine the liquid limit of fine-grained soils as an aid to soil classification. The test can also be used to obtain the undrained shear strength of a fine-grained soil, based on the “cone factor,” K. Reports from different authors show K values ranging from 0.4–1.33. Differences are mostly attributed to the cone surface roughness. This article presents a reinterpretation of several experimental observations available in the literature. It is observed that besides the cone roughness, testing methods have a clear influence when calibrating the fall cone for determining the undrained shear strength of materials with low and very low consistency. The results show that existing K reports should be extrapolated with care. Finally, we propose a series of recommendations and good practices for future calibrations.</description><issn>0149-6115</issn><issn>1945-7545</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2018</creationdate><recordtype>article</recordtype><recordid>eNqlkM1KxDAURoMoWEdXvkCXglRz0_x1p9SZURlwU9chbRLs0GlLU0F9ejPWhYuBEV3dcPPl5PAhdA74ChjB18vikWAQmGB2gCLIKEsEo-wQRRholnAAdoxOvF9jDJIIEqG7vGt9beygxzqc4q6Nxxcbz996O9Qb2466iXPd1OUUiDv3db_QTdh3rY0L68dTdOR04-3Z95yh58W8yO-T1dPyIb9dJZpmdEzCh8aRkmMBVjrOrbRSGCe1rkxpSk2yUlLOWFpyRhjFBIShGWMyBVsRIdIZupy41dB5P1in-iCph3cFWG0LUD8KCOmbKa39uFHr7nVog9w2oigorgCCiFQfdb_rueqN-w1C7kVc7EL8RRgLQv8tDGQP4hP2kqhD</recordid><startdate>20181101</startdate><enddate>20181101</enddate><creator>Llano-Serna, Marcelo A.</creator><creator>Farias, Márcio M.</creator><creator>Pedroso, Dorival M.</creator><creator>Williams, David J.</creator><creator>Sheng, Daichao</creator><scope>AAYXX</scope><scope>CITATION</scope><orcidid>https://orcid.org/0000-0002-4395-8636</orcidid></search><sort><creationdate>20181101</creationdate><title>Considerations on the Experimental Calibration of the Fall Cone Test</title><author>Llano-Serna, Marcelo A. ; Farias, Márcio M. ; Pedroso, Dorival M. ; Williams, David J. ; Sheng, Daichao</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-a494t-272df2b6071e8f66e8e87df8aacdbdba29b846553b652540217d4955831ec2773</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2018</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Llano-Serna, Marcelo A.</creatorcontrib><creatorcontrib>Farias, Márcio M.</creatorcontrib><creatorcontrib>Pedroso, Dorival M.</creatorcontrib><creatorcontrib>Williams, David J.</creatorcontrib><creatorcontrib>Sheng, Daichao</creatorcontrib><collection>CrossRef</collection><jtitle>Geotechnical testing journal</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Llano-Serna, Marcelo A.</au><au>Farias, Márcio M.</au><au>Pedroso, Dorival M.</au><au>Williams, David J.</au><au>Sheng, Daichao</au><au>Suits, L. David</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Considerations on the Experimental Calibration of the Fall Cone Test</atitle><jtitle>Geotechnical testing journal</jtitle><date>2018-11-01</date><risdate>2018</risdate><volume>41</volume><issue>6</issue><spage>1131</spage><epage>1138</epage><pages>1131-1138</pages><issn>0149-6115</issn><eissn>1945-7545</eissn><coden>GTJODJ</coden><abstract>The fall cone test is widely used in soil mechanics to determine the liquid limit of fine-grained soils as an aid to soil classification. The test can also be used to obtain the undrained shear strength of a fine-grained soil, based on the “cone factor,” K. Reports from different authors show K values ranging from 0.4–1.33. Differences are mostly attributed to the cone surface roughness. This article presents a reinterpretation of several experimental observations available in the literature. It is observed that besides the cone roughness, testing methods have a clear influence when calibrating the fall cone for determining the undrained shear strength of materials with low and very low consistency. The results show that existing K reports should be extrapolated with care. Finally, we propose a series of recommendations and good practices for future calibrations.</abstract><doi>10.1520/GTJ20170205</doi><tpages>8</tpages><orcidid>https://orcid.org/0000-0002-4395-8636</orcidid></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0149-6115 |
ispartof | Geotechnical testing journal, 2018-11, Vol.41 (6), p.1131-1138 |
issn | 0149-6115 1945-7545 |
language | eng |
recordid | cdi_crossref_primary_10_1520_GTJ20170205 |
source | ASTM Journals |
title | Considerations on the Experimental Calibration of the Fall Cone Test |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-29T10%3A23%3A23IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-astm_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Considerations%20on%20the%20Experimental%20Calibration%20of%20the%20Fall%20Cone%20Test&rft.jtitle=Geotechnical%20testing%20journal&rft.au=Llano-Serna,%20Marcelo%20A.&rft.date=2018-11-01&rft.volume=41&rft.issue=6&rft.spage=1131&rft.epage=1138&rft.pages=1131-1138&rft.issn=0149-6115&rft.eissn=1945-7545&rft.coden=GTJODJ&rft_id=info:doi/10.1520/GTJ20170205&rft_dat=%3Castm_cross%3E10_1520_GTJ20170205%3C/astm_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-a494t-272df2b6071e8f66e8e87df8aacdbdba29b846553b652540217d4955831ec2773%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true |