Loading…
Identification of Ammunitions Used in a Lethal Robbery. Comparison Between Scanning Electron Microscopy/Energy Dispersive X-Ray Analysis (SEM-EDX) and Instrumental Neutron Activation Analysis (INAA) Measurements
Gunshot residues (GSRs) sampled in proximity of the hole left by a bullet on the clothes of a person wounded during a homicidal robbery, have been examined by the authors, on request of the Court. These investigations have shown that gunshot residues GSRs can be considered consistent with a shot dis...
Saved in:
Published in: | Journal of forensic sciences 1993-09, Vol.38 (5), p.1237-1242 |
---|---|
Main Authors: | , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Gunshot residues (GSRs) sampled in proximity of the hole left by a bullet on the clothes of a person wounded during a homicidal robbery, have been examined by the authors, on request of the Court. These investigations have shown that gunshot residues GSRs can be considered consistent with a shot discharged by a pistol SIG SAUER, found on the crime scene, with Sellier & Bellot (S&B) ammunition. Actually, these cartridges leave residues in which tin is present together with lead and barium, as found in the examined GSRs. An evaluation of the firing distance and a comparison between scanning electron microscopy with energy dispersive X-ray analysis (SEM-EDX) and Instrumental Neutron Activation Analysis (INAA) have been also performed. |
---|---|
ISSN: | 0022-1198 1556-4029 |
DOI: | 10.1520/JFS13530J |