Resistance and Stress Finite Element Analysis of Different Types of Fixation for Mandibular Orthognathic Surgery

Abstract The aim of this study was to evaluate the stress and dislodgement resistance by finite element analysis of different types of fixation in mandibular orthognathic surgery. A 3D solid finite element model of a hemi-mandible was obtained. A bilateral sagittal split osteotomy was simulated and...

Full description

Saved in:
Bibliographic Details
Published in:Brazilian dental journal 2016-06, Vol.27 (3), p.284-291
Main Authors: Stringhini, Diego José, Sommerfeld, Ricardo, Uetanabaro, Lucas Caetano, Leonardi, Denise Piotto, Araújo, Melissa Rodrigues, Rebellato, Nelson Luís Barbosa, Costa, Delson João da, Scariot, Rafaela
Format: Article
Language:English
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Abstract The aim of this study was to evaluate the stress and dislodgement resistance by finite element analysis of different types of fixation in mandibular orthognathic surgery. A 3D solid finite element model of a hemi-mandible was obtained. A bilateral sagittal split osteotomy was simulated and the distal segment was advanced 5 mm forward. After the adjustment and superimposing of segments, 9 different types of osteosynthesis with 2.0 miniplates and screws were simulated: A, one 4-hole conventional straight miniplate; B, one 4-hole locking straight miniplate; C, one 4-hole conventional miniplate and one bicortical screw; D, one 4-hole locking miniplate and 1 bicortical screws; E, one 6-hole conventional straight miniplate; F, one 6-hole locking miniplate; G, two 4-hole conventional straight miniplates; H, two 4-hole locking straight miniplates; and I, 3 bicortical screws in an inverted-L pattern. In each model, forces simulating the masticatory muscles were applied. The values of stress in the plates and screws were checked. The dislodgement resistance was checked at the proximal segment since the distal segment was stable because of the screen at the occlusal tooth. The regions with the lowest and highest displacement were measured. The offset between the osteotomized segments was verified by millimeter intervals. Inverted-L with bicortical screws was the model that had the lowest dislodgment and the model with the lowest tension was the one with two conventional plates. The results suggest that the tension was better distributed in the locking miniplates, but the locking screws presented higher concentration of tension. Resumo O objetivo deste estudo foi verificar o estresse e a resistência ao deslocamento, pela análise de elementos finitos, de diferentes tipos de fixação em cirurgia ortognática mandibular. Um modelo 3D de elementos finitos sólidos de uma hemi-mandíbula foi obtido. Uma osteotomia sagital bilateral foi simulada e o segmento distal foi avançado 5 mm. Após o ajuste e sobreposição dos segmentos, foram simulados 9 diferentes tipos de osteossíntese com miniplacas e parafusos 2.0: A, uma miniplaca reta convencional de 4 furos; B, uma miniplaca reta lock de 4 furos; C, uma miniplaca convencional de 4 furos e um parafuso bicortical; D, uma placa lock de 4 furos e 1 parafuso bicortical; E, uma miniplaca reta convencional de 6 furos; F, uma miniplaca lock de 6 furos; G, duas miniplacas retas convencionais de 4 furos; H, duas miniplacas lock de
ISSN:0103-6440
0103-6440
DOI:10.1590/0103-6440201600336