Micrographic evaluation of different widia compositions of orthodontic pliers submitted to peracetic acid and intensive use

Abstract Introduction The sterilization and disinfection procedures should be adapted to the chemical profile of the metal alloys present in the instruments. Objective This study aimed to perform a micrographic assessment on the surface characteristics of the widia of orthodontic pliers with two all...

Full description

Saved in:
Bibliographic Details
Published in:Revista de Odontologia da UNESP 2020, Vol.49
Main Authors: MARCIAL, Érika Zoli, NEVES, José Guilherme, CORRER-SOBRINHO, Lourenço, MENEZES, Carolina Carmo de, GODOI, Ana Paula Terossi de, VEDOVELLO FILHO, Mário, COSTA, Ana Rosa
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Abstract Introduction The sterilization and disinfection procedures should be adapted to the chemical profile of the metal alloys present in the instruments. Objective This study aimed to perform a micrographic assessment on the surface characteristics of the widia of orthodontic pliers with two alloy compositions subjected to the action of 0.2% peracetic acid and intensive use. Material and method Twenty distal cutting pliers were divided into two groups (n=10) according to widia composition (%wt): W1- 85% to 87% of tungsten carbide (TC) and other components in the proportion of 13% to 15% and W2 – 87.5% to 88.5% of tungsten carbide and 11.5% to 12.5% for other components. All the pliers were assessed in a stereoscopic magnifying glass (32x) after three treatments: before use (T0); after cutting 100 segments of rectangular stainless-steel wires – intensive use (T1); and after 100 sterilization cycles in 0.2% peracetic acid and intensive use (T2). The cutting sites of all pliers were standardized. Widia regions were defined by line “A” representing T1 and line “B” representing T2. A frequency distribution table and Fisher’s exact test (α=0.05) was performed. We assessed two widia from each composition and treatment in SEM and energy-dispersive X-ray spectroscopy (EDS/SEM). Result The results showed that W1 pliers presented significantly fewer defects after the sterilization cycles with peracetic acid and intensive use than W2 pliers (p=0.0198). There were no differences between both pliers after intensive use (p=1.000). Conclusion The SEM images and EDS analyses showed changes in widia surfaces after the different treatments. Widia composition affected the resistance of the orthodontic pliers after sterilization cycles with 0.2% peracetic acid and intensive use. Resumo Introdução Os procedimentos de esterilização e desinfecção devem ser adaptados ao perfil químico das ligas metálicas presentes nos instrumentos. Objetivo O objetivo do estudo foi realizar uma avaliação micrográfica das características da superfície da widia de alicates ortodônticos com duas composições de ligas submetidas à ação de ácido peracético a 0,2% e uso intensivo. Material e método Vinte alicates de corte distal foram divididos em dois grupos (n=10), de acordo com a composição widia (% em peso): W1- 85% a 87% de carboneto de tungstênio e outros componentes na proporção de 13% a 15% e W2 - 87,5% a 88,5% de carboneto de tungstênio e 11,5% a 12,5% para outros componentes. Os alicates fo
ISSN:0101-1774
1807-2577
DOI:10.1590/1807-2577.02120