In the present investigation, an experimental dental arch model fabricated in epoxy was assayed in Kratos universal testing machine to study the mechanical behavior of ethylene and vinyl acetate copolymer (EVA) in the form of mouthguard for sports and flat plate. The following variables were conside...

Full description

Saved in:
Bibliographic Details
Published in:Brazilian dental journal 2007, Vol.18 (4), p.324-328
Main Authors: Coto, Neide Pena, Dias, Reinaldo Brito e, Costa, Ricardo Aurélio, Antoniazzi, Tatiana Fioresi, Carvalho, Eduardo Pena Coto de
Format: Article
Language:English
Citations: Items that this one cites
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by
cites cdi_FETCH-crossref_primary_10_1590_S0103_644020070004000103
container_end_page 328
container_issue 4
container_start_page 324
container_title Brazilian dental journal
container_volume 18
creator Coto, Neide Pena
Dias, Reinaldo Brito e
Costa, Ricardo Aurélio
Antoniazzi, Tatiana Fioresi
Carvalho, Eduardo Pena Coto de
description In the present investigation, an experimental dental arch model fabricated in epoxy was assayed in Kratos universal testing machine to study the mechanical behavior of ethylene and vinyl acetate copolymer (EVA) in the form of mouthguard for sports and flat plate. The following variables were considered: thickness (3 and 4-mm plates), temperature (room and mouth temperature) and presence/absence of artificial saliva. Mechanical properties of EVA were tested under compressive strength: apparent absorbed energy (J.mm-1), maximum tension (N.mm-1), maximum dislocation (mm) and maximum strength (N). Data were recorded and modeled mathematically. Regarding the absorbed energy, maximum tension and maximum force, it was verified that the higher the thickness of the mouthguards, the better the results of force dissipation and redirection to the system and to several regions of the dental arch. In the presence of saliva and close to mouth temperature, the material responded positively to these alterations, resenting increased ductibility as well as improved mechanical responses. Regarding maximum dislocation, it was observed a better accommodation of the occlusion under conditions that simulate those observed in the oral environment. In conclusion, EVA proved to be an adequate material for fabrication of mouthguards and interocclusal splints. In addition, EVA showed good results in force dissipation and demonstrated a shock-absorbing capacity and a great protection potential. Um modelo experimental de arco dentário, obtido em epóxi, acoplado a uma máquina universal de ensaios Kratos, foi utilizado para estudar o comportamento mecânico do copolímero de etileno e acetato de vinila (EVA), na forma de protetor bucal para esporte e placa plana. As seguintes variáveis foram observadas: espessura (lâminas de 3 e 4 mm), temperatura (ambiente e bucal) e presença ou ausência de saliva artificial. As propriedades mecânicas do EVA, foram testadas ao esforço compressivo: energia aparente absorvida (J.mm-1), tensão máxima (N.mm-1), deslocamento máximo (mm) e força máxima (N). Dados foram registrados e modelados matematicamente. Considerando a energia aparente absorvida, tensão máxima e força máxima, verificou-se que com o aumento da espessura dos protetores bucais houve melhores resultados de dissipação de forças compressivas e seu redirecionamento para o sistema e diversas regiões do arco dental. Com a presença de saliva e temperatura próxima a bucal o material respondeu positiva
doi_str_mv 10.1590/S0103-64402007000400010
format article
fullrecord <record><control><sourceid>crossref</sourceid><recordid>TN_cdi_crossref_primary_10_1590_S0103_64402007000400010</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>10_1590_S0103_64402007000400010</sourcerecordid><originalsourceid>FETCH-crossref_primary_10_1590_S0103_644020070004000103</originalsourceid><addsrcrecordid>eNpjYJA3NNAzNLU00A82MDQw1jUzMTEwMjAwNzAwMAFiQwMmBk64BAsSm4OBq7g4ywCo2MTYkpNByM9fIcQzxMdVwTHM0dPH0cnHlYeBNS0xpziVF0pzM5i7uYY4e-gmF-UXFxelpsUXFGXmJhZVxhsaxIOcEA92QjyGE4zJ1wkAoDQ1lQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>NO TITLE AVAILABLE</title><source>SciELO Brazil</source><creator>Coto, Neide Pena ; Dias, Reinaldo Brito e ; Costa, Ricardo Aurélio ; Antoniazzi, Tatiana Fioresi ; Carvalho, Eduardo Pena Coto de</creator><creatorcontrib>Coto, Neide Pena ; Dias, Reinaldo Brito e ; Costa, Ricardo Aurélio ; Antoniazzi, Tatiana Fioresi ; Carvalho, Eduardo Pena Coto de</creatorcontrib><description>In the present investigation, an experimental dental arch model fabricated in epoxy was assayed in Kratos universal testing machine to study the mechanical behavior of ethylene and vinyl acetate copolymer (EVA) in the form of mouthguard for sports and flat plate. The following variables were considered: thickness (3 and 4-mm plates), temperature (room and mouth temperature) and presence/absence of artificial saliva. Mechanical properties of EVA were tested under compressive strength: apparent absorbed energy (J.mm-1), maximum tension (N.mm-1), maximum dislocation (mm) and maximum strength (N). Data were recorded and modeled mathematically. Regarding the absorbed energy, maximum tension and maximum force, it was verified that the higher the thickness of the mouthguards, the better the results of force dissipation and redirection to the system and to several regions of the dental arch. In the presence of saliva and close to mouth temperature, the material responded positively to these alterations, resenting increased ductibility as well as improved mechanical responses. Regarding maximum dislocation, it was observed a better accommodation of the occlusion under conditions that simulate those observed in the oral environment. In conclusion, EVA proved to be an adequate material for fabrication of mouthguards and interocclusal splints. In addition, EVA showed good results in force dissipation and demonstrated a shock-absorbing capacity and a great protection potential. Um modelo experimental de arco dentário, obtido em epóxi, acoplado a uma máquina universal de ensaios Kratos, foi utilizado para estudar o comportamento mecânico do copolímero de etileno e acetato de vinila (EVA), na forma de protetor bucal para esporte e placa plana. As seguintes variáveis foram observadas: espessura (lâminas de 3 e 4 mm), temperatura (ambiente e bucal) e presença ou ausência de saliva artificial. As propriedades mecânicas do EVA, foram testadas ao esforço compressivo: energia aparente absorvida (J.mm-1), tensão máxima (N.mm-1), deslocamento máximo (mm) e força máxima (N). Dados foram registrados e modelados matematicamente. Considerando a energia aparente absorvida, tensão máxima e força máxima, verificou-se que com o aumento da espessura dos protetores bucais houve melhores resultados de dissipação de forças compressivas e seu redirecionamento para o sistema e diversas regiões do arco dental. Com a presença de saliva e temperatura próxima a bucal o material respondeu positivamente a essas alterações aumentando sua ductibilidade apresentando assim melhora em sua resposta mecânica. Com respeito ao deslocamento máximo observou-se que houve melhor acomodação da oclusão quando em condições próximas à bucal. Conclue-se que o EVA provou ser um material adequado para a confecção de protetores bucais para esporte e placas interoclusais.O EVA mostrou melhores resultados na dissipação de forças demonstrando sua grande capacidade amortecedora e grande potencial de proteção.</description><identifier>ISSN: 0103-6440</identifier><identifier>EISSN: 0103-6440</identifier><identifier>DOI: 10.1590/S0103-64402007000400010</identifier><language>eng</language><ispartof>Brazilian dental journal, 2007, Vol.18 (4), p.324-328</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-crossref_primary_10_1590_S0103_644020070004000103</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,4024,27923,27924,27925</link.rule.ids></links><search><creatorcontrib>Coto, Neide Pena</creatorcontrib><creatorcontrib>Dias, Reinaldo Brito e</creatorcontrib><creatorcontrib>Costa, Ricardo Aurélio</creatorcontrib><creatorcontrib>Antoniazzi, Tatiana Fioresi</creatorcontrib><creatorcontrib>Carvalho, Eduardo Pena Coto de</creatorcontrib><title>NO TITLE AVAILABLE</title><title>Brazilian dental journal</title><description>In the present investigation, an experimental dental arch model fabricated in epoxy was assayed in Kratos universal testing machine to study the mechanical behavior of ethylene and vinyl acetate copolymer (EVA) in the form of mouthguard for sports and flat plate. The following variables were considered: thickness (3 and 4-mm plates), temperature (room and mouth temperature) and presence/absence of artificial saliva. Mechanical properties of EVA were tested under compressive strength: apparent absorbed energy (J.mm-1), maximum tension (N.mm-1), maximum dislocation (mm) and maximum strength (N). Data were recorded and modeled mathematically. Regarding the absorbed energy, maximum tension and maximum force, it was verified that the higher the thickness of the mouthguards, the better the results of force dissipation and redirection to the system and to several regions of the dental arch. In the presence of saliva and close to mouth temperature, the material responded positively to these alterations, resenting increased ductibility as well as improved mechanical responses. Regarding maximum dislocation, it was observed a better accommodation of the occlusion under conditions that simulate those observed in the oral environment. In conclusion, EVA proved to be an adequate material for fabrication of mouthguards and interocclusal splints. In addition, EVA showed good results in force dissipation and demonstrated a shock-absorbing capacity and a great protection potential. Um modelo experimental de arco dentário, obtido em epóxi, acoplado a uma máquina universal de ensaios Kratos, foi utilizado para estudar o comportamento mecânico do copolímero de etileno e acetato de vinila (EVA), na forma de protetor bucal para esporte e placa plana. As seguintes variáveis foram observadas: espessura (lâminas de 3 e 4 mm), temperatura (ambiente e bucal) e presença ou ausência de saliva artificial. As propriedades mecânicas do EVA, foram testadas ao esforço compressivo: energia aparente absorvida (J.mm-1), tensão máxima (N.mm-1), deslocamento máximo (mm) e força máxima (N). Dados foram registrados e modelados matematicamente. Considerando a energia aparente absorvida, tensão máxima e força máxima, verificou-se que com o aumento da espessura dos protetores bucais houve melhores resultados de dissipação de forças compressivas e seu redirecionamento para o sistema e diversas regiões do arco dental. Com a presença de saliva e temperatura próxima a bucal o material respondeu positivamente a essas alterações aumentando sua ductibilidade apresentando assim melhora em sua resposta mecânica. Com respeito ao deslocamento máximo observou-se que houve melhor acomodação da oclusão quando em condições próximas à bucal. Conclue-se que o EVA provou ser um material adequado para a confecção de protetores bucais para esporte e placas interoclusais.O EVA mostrou melhores resultados na dissipação de forças demonstrando sua grande capacidade amortecedora e grande potencial de proteção.</description><issn>0103-6440</issn><issn>0103-6440</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2007</creationdate><recordtype>article</recordtype><recordid>eNpjYJA3NNAzNLU00A82MDQw1jUzMTEwMjAwNzAwMAFiQwMmBk64BAsSm4OBq7g4ywCo2MTYkpNByM9fIcQzxMdVwTHM0dPH0cnHlYeBNS0xpziVF0pzM5i7uYY4e-gmF-UXFxelpsUXFGXmJhZVxhsaxIOcEA92QjyGE4zJ1wkAoDQ1lQ</recordid><startdate>2007</startdate><enddate>2007</enddate><creator>Coto, Neide Pena</creator><creator>Dias, Reinaldo Brito e</creator><creator>Costa, Ricardo Aurélio</creator><creator>Antoniazzi, Tatiana Fioresi</creator><creator>Carvalho, Eduardo Pena Coto de</creator><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>2007</creationdate><title>NO TITLE AVAILABLE</title><author>Coto, Neide Pena ; Dias, Reinaldo Brito e ; Costa, Ricardo Aurélio ; Antoniazzi, Tatiana Fioresi ; Carvalho, Eduardo Pena Coto de</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-crossref_primary_10_1590_S0103_644020070004000103</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2007</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Coto, Neide Pena</creatorcontrib><creatorcontrib>Dias, Reinaldo Brito e</creatorcontrib><creatorcontrib>Costa, Ricardo Aurélio</creatorcontrib><creatorcontrib>Antoniazzi, Tatiana Fioresi</creatorcontrib><creatorcontrib>Carvalho, Eduardo Pena Coto de</creatorcontrib><collection>CrossRef</collection><jtitle>Brazilian dental journal</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Coto, Neide Pena</au><au>Dias, Reinaldo Brito e</au><au>Costa, Ricardo Aurélio</au><au>Antoniazzi, Tatiana Fioresi</au><au>Carvalho, Eduardo Pena Coto de</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>NO TITLE AVAILABLE</atitle><jtitle>Brazilian dental journal</jtitle><date>2007</date><risdate>2007</risdate><volume>18</volume><issue>4</issue><spage>324</spage><epage>328</epage><pages>324-328</pages><issn>0103-6440</issn><eissn>0103-6440</eissn><abstract>In the present investigation, an experimental dental arch model fabricated in epoxy was assayed in Kratos universal testing machine to study the mechanical behavior of ethylene and vinyl acetate copolymer (EVA) in the form of mouthguard for sports and flat plate. The following variables were considered: thickness (3 and 4-mm plates), temperature (room and mouth temperature) and presence/absence of artificial saliva. Mechanical properties of EVA were tested under compressive strength: apparent absorbed energy (J.mm-1), maximum tension (N.mm-1), maximum dislocation (mm) and maximum strength (N). Data were recorded and modeled mathematically. Regarding the absorbed energy, maximum tension and maximum force, it was verified that the higher the thickness of the mouthguards, the better the results of force dissipation and redirection to the system and to several regions of the dental arch. In the presence of saliva and close to mouth temperature, the material responded positively to these alterations, resenting increased ductibility as well as improved mechanical responses. Regarding maximum dislocation, it was observed a better accommodation of the occlusion under conditions that simulate those observed in the oral environment. In conclusion, EVA proved to be an adequate material for fabrication of mouthguards and interocclusal splints. In addition, EVA showed good results in force dissipation and demonstrated a shock-absorbing capacity and a great protection potential. Um modelo experimental de arco dentário, obtido em epóxi, acoplado a uma máquina universal de ensaios Kratos, foi utilizado para estudar o comportamento mecânico do copolímero de etileno e acetato de vinila (EVA), na forma de protetor bucal para esporte e placa plana. As seguintes variáveis foram observadas: espessura (lâminas de 3 e 4 mm), temperatura (ambiente e bucal) e presença ou ausência de saliva artificial. As propriedades mecânicas do EVA, foram testadas ao esforço compressivo: energia aparente absorvida (J.mm-1), tensão máxima (N.mm-1), deslocamento máximo (mm) e força máxima (N). Dados foram registrados e modelados matematicamente. Considerando a energia aparente absorvida, tensão máxima e força máxima, verificou-se que com o aumento da espessura dos protetores bucais houve melhores resultados de dissipação de forças compressivas e seu redirecionamento para o sistema e diversas regiões do arco dental. Com a presença de saliva e temperatura próxima a bucal o material respondeu positivamente a essas alterações aumentando sua ductibilidade apresentando assim melhora em sua resposta mecânica. Com respeito ao deslocamento máximo observou-se que houve melhor acomodação da oclusão quando em condições próximas à bucal. Conclue-se que o EVA provou ser um material adequado para a confecção de protetores bucais para esporte e placas interoclusais.O EVA mostrou melhores resultados na dissipação de forças demonstrando sua grande capacidade amortecedora e grande potencial de proteção.</abstract><doi>10.1590/S0103-64402007000400010</doi></addata></record>
fulltext fulltext
identifier ISSN: 0103-6440
ispartof Brazilian dental journal, 2007, Vol.18 (4), p.324-328
issn 0103-6440
0103-6440
language eng
recordid cdi_crossref_primary_10_1590_S0103_64402007000400010
source SciELO Brazil
title NO TITLE AVAILABLE
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-06T06%3A58%3A57IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-crossref&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=NO%20TITLE%20AVAILABLE&rft.jtitle=Brazilian%20dental%20journal&rft.au=Coto,%20Neide%20Pena&rft.date=2007&rft.volume=18&rft.issue=4&rft.spage=324&rft.epage=328&rft.pages=324-328&rft.issn=0103-6440&rft.eissn=0103-6440&rft_id=info:doi/10.1590/S0103-64402007000400010&rft_dat=%3Ccrossref%3E10_1590_S0103_64402007000400010%3C/crossref%3E%3Cgrp_id%3Ecdi_FETCH-crossref_primary_10_1590_S0103_644020070004000103%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true