Loading…
P-64: Improvement of Color Gamut Using New Auxiliary Negative Pulse in AC-PDPs
A new auxiliary negative pulse is proposed to improve the color purity by reducing the neon (Ne) emission of 585 nm in an ac PDP. Applying the auxiliary negative pulse to the address electrodes during a sustain‐period induces a new discharge mode that can reduce the Ne emission remarkably. For this...
Saved in:
Published in: | SID International Symposium Digest of technical papers 2002-05, Vol.33 (1), p.444-447 |
---|---|
Main Authors: | , , , |
Format: | Article |
Language: | English |
Citations: | Items that this one cites |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | |
---|---|
cites | cdi_FETCH-LOGICAL-c1120-cca090bcece75855ba76540b32ba8ed740fb74dec926a49dd9a7d825ff31b9133 |
container_end_page | 447 |
container_issue | 1 |
container_start_page | 444 |
container_title | SID International Symposium Digest of technical papers |
container_volume | 33 |
creator | Kim, Hyun Jang, Sang-Hun Tae, Heung-Sik Chien, Sung-Il |
description | A new auxiliary negative pulse is proposed to improve the color purity by reducing the neon (Ne) emission of 585 nm in an ac PDP. Applying the auxiliary negative pulse to the address electrodes during a sustain‐period induces a new discharge mode that can reduce the Ne emission remarkably. For this new discharge mode, the change in the Ne emission intensity including the discharge characteristics is measured and the corresponding mechanism is also analyzed. As a result, it is found that a color gamut area is expanded by approximately 8.5 % in comparison with a conventional case. |
doi_str_mv | 10.1889/1.1830826 |
format | article |
fullrecord | <record><control><sourceid>istex_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1889_1_1830826</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>ark_67375_WNG_P3X971GQ_X</sourcerecordid><originalsourceid>FETCH-LOGICAL-c1120-cca090bcece75855ba76540b32ba8ed740fb74dec926a49dd9a7d825ff31b9133</originalsourceid><addsrcrecordid>eNp1kF1LwzAUhoMoOKcX_oPcehGXNGnSeDc6rYMxK264u5C26Yi262jaffx7IxveefVyDs9zOLwA3BP8SKJIjogPiqOAX4BBQHiEMAnlJRhgLAWSnK-uwY1zXxhTypgcgHmKOHuC03rbNjtTm00HmxLGTdW0MNF138Gls5s1nJs9HPcHW1ndHv201p3dGZj2lTPQbuA4RukkdbfgqtR-dXfOIVi-PC_iVzR7S6bxeIZyQgKM8lxjibPc5EaEURhmWvCQ4YwGmY5MIRguM8EKk8uAayaLQmpRREFYlpRkklA6BA-nu3nbONeaUm1bW_vXFMHqtwhF1LkIz45O7N5W5vg_qD4mi5SKEHsDnQzrOnP4M3T7rbjwhPqcJyqlKylI8q5W9Ad__WwA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>P-64: Improvement of Color Gamut Using New Auxiliary Negative Pulse in AC-PDPs</title><source>Wiley</source><creator>Kim, Hyun ; Jang, Sang-Hun ; Tae, Heung-Sik ; Chien, Sung-Il</creator><creatorcontrib>Kim, Hyun ; Jang, Sang-Hun ; Tae, Heung-Sik ; Chien, Sung-Il</creatorcontrib><description>A new auxiliary negative pulse is proposed to improve the color purity by reducing the neon (Ne) emission of 585 nm in an ac PDP. Applying the auxiliary negative pulse to the address electrodes during a sustain‐period induces a new discharge mode that can reduce the Ne emission remarkably. For this new discharge mode, the change in the Ne emission intensity including the discharge characteristics is measured and the corresponding mechanism is also analyzed. As a result, it is found that a color gamut area is expanded by approximately 8.5 % in comparison with a conventional case.</description><identifier>ISSN: 0097-966X</identifier><identifier>EISSN: 2168-0159</identifier><identifier>DOI: 10.1889/1.1830826</identifier><language>eng</language><publisher>Oxford, UK: Blackwell Publishing Ltd</publisher><ispartof>SID International Symposium Digest of technical papers, 2002-05, Vol.33 (1), p.444-447</ispartof><rights>2002 Society for Information Display</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c1120-cca090bcece75855ba76540b32ba8ed740fb74dec926a49dd9a7d825ff31b9133</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,777,781,27905,27906</link.rule.ids></links><search><creatorcontrib>Kim, Hyun</creatorcontrib><creatorcontrib>Jang, Sang-Hun</creatorcontrib><creatorcontrib>Tae, Heung-Sik</creatorcontrib><creatorcontrib>Chien, Sung-Il</creatorcontrib><title>P-64: Improvement of Color Gamut Using New Auxiliary Negative Pulse in AC-PDPs</title><title>SID International Symposium Digest of technical papers</title><description>A new auxiliary negative pulse is proposed to improve the color purity by reducing the neon (Ne) emission of 585 nm in an ac PDP. Applying the auxiliary negative pulse to the address electrodes during a sustain‐period induces a new discharge mode that can reduce the Ne emission remarkably. For this new discharge mode, the change in the Ne emission intensity including the discharge characteristics is measured and the corresponding mechanism is also analyzed. As a result, it is found that a color gamut area is expanded by approximately 8.5 % in comparison with a conventional case.</description><issn>0097-966X</issn><issn>2168-0159</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2002</creationdate><recordtype>article</recordtype><recordid>eNp1kF1LwzAUhoMoOKcX_oPcehGXNGnSeDc6rYMxK264u5C26Yi262jaffx7IxveefVyDs9zOLwA3BP8SKJIjogPiqOAX4BBQHiEMAnlJRhgLAWSnK-uwY1zXxhTypgcgHmKOHuC03rbNjtTm00HmxLGTdW0MNF138Gls5s1nJs9HPcHW1ndHv201p3dGZj2lTPQbuA4RukkdbfgqtR-dXfOIVi-PC_iVzR7S6bxeIZyQgKM8lxjibPc5EaEURhmWvCQ4YwGmY5MIRguM8EKk8uAayaLQmpRREFYlpRkklA6BA-nu3nbONeaUm1bW_vXFMHqtwhF1LkIz45O7N5W5vg_qD4mi5SKEHsDnQzrOnP4M3T7rbjwhPqcJyqlKylI8q5W9Ad__WwA</recordid><startdate>200205</startdate><enddate>200205</enddate><creator>Kim, Hyun</creator><creator>Jang, Sang-Hun</creator><creator>Tae, Heung-Sik</creator><creator>Chien, Sung-Il</creator><general>Blackwell Publishing Ltd</general><scope>BSCLL</scope><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>200205</creationdate><title>P-64: Improvement of Color Gamut Using New Auxiliary Negative Pulse in AC-PDPs</title><author>Kim, Hyun ; Jang, Sang-Hun ; Tae, Heung-Sik ; Chien, Sung-Il</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c1120-cca090bcece75855ba76540b32ba8ed740fb74dec926a49dd9a7d825ff31b9133</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2002</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Kim, Hyun</creatorcontrib><creatorcontrib>Jang, Sang-Hun</creatorcontrib><creatorcontrib>Tae, Heung-Sik</creatorcontrib><creatorcontrib>Chien, Sung-Il</creatorcontrib><collection>Istex</collection><collection>CrossRef</collection><jtitle>SID International Symposium Digest of technical papers</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Kim, Hyun</au><au>Jang, Sang-Hun</au><au>Tae, Heung-Sik</au><au>Chien, Sung-Il</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>P-64: Improvement of Color Gamut Using New Auxiliary Negative Pulse in AC-PDPs</atitle><jtitle>SID International Symposium Digest of technical papers</jtitle><date>2002-05</date><risdate>2002</risdate><volume>33</volume><issue>1</issue><spage>444</spage><epage>447</epage><pages>444-447</pages><issn>0097-966X</issn><eissn>2168-0159</eissn><abstract>A new auxiliary negative pulse is proposed to improve the color purity by reducing the neon (Ne) emission of 585 nm in an ac PDP. Applying the auxiliary negative pulse to the address electrodes during a sustain‐period induces a new discharge mode that can reduce the Ne emission remarkably. For this new discharge mode, the change in the Ne emission intensity including the discharge characteristics is measured and the corresponding mechanism is also analyzed. As a result, it is found that a color gamut area is expanded by approximately 8.5 % in comparison with a conventional case.</abstract><cop>Oxford, UK</cop><pub>Blackwell Publishing Ltd</pub><doi>10.1889/1.1830826</doi><tpages>4</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0097-966X |
ispartof | SID International Symposium Digest of technical papers, 2002-05, Vol.33 (1), p.444-447 |
issn | 0097-966X 2168-0159 |
language | eng |
recordid | cdi_crossref_primary_10_1889_1_1830826 |
source | Wiley |
title | P-64: Improvement of Color Gamut Using New Auxiliary Negative Pulse in AC-PDPs |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-20T05%3A45%3A33IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-istex_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=P-64:%20Improvement%20of%20Color%20Gamut%20Using%20New%20Auxiliary%20Negative%20Pulse%20in%20AC-PDPs&rft.jtitle=SID%20International%20Symposium%20Digest%20of%20technical%20papers&rft.au=Kim,%20Hyun&rft.date=2002-05&rft.volume=33&rft.issue=1&rft.spage=444&rft.epage=447&rft.pages=444-447&rft.issn=0097-966X&rft.eissn=2168-0159&rft_id=info:doi/10.1889/1.1830826&rft_dat=%3Cistex_cross%3Eark_67375_WNG_P3X971GQ_X%3C/istex_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c1120-cca090bcece75855ba76540b32ba8ed740fb74dec926a49dd9a7d825ff31b9133%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true |