Loading…

Nanoparticles Based Carbon Paste Electrodes for the Determination of Flupentixol Dihydrochloride: Application to Pharmaceutical Analysis and Pharmacokinetic Study

Five different carbon paste electrodes were developed and applied for the electrochemical determination of flupentixol dihydrochloride. Sensor 1 was fabricated using a mixture of graphite powder and multiwall-carbon-nanotubes. Different additives were used to improve the performance and the sensitiv...

Full description

Saved in:
Bibliographic Details
Published in:International journal of electrochemical science 2016-12, Vol.11 (12), p.10715-10731
Main Author: Abdallah, Nehad A.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c316t-2241429032090a078ca73348c18b4b11df640baf953ec6d204da46a2746cfe503
cites cdi_FETCH-LOGICAL-c316t-2241429032090a078ca73348c18b4b11df640baf953ec6d204da46a2746cfe503
container_end_page 10731
container_issue 12
container_start_page 10715
container_title International journal of electrochemical science
container_volume 11
creator Abdallah, Nehad A.
description Five different carbon paste electrodes were developed and applied for the electrochemical determination of flupentixol dihydrochloride. Sensor 1 was fabricated using a mixture of graphite powder and multiwall-carbon-nanotubes. Different additives were used to improve the performance and the sensitivity of the carbon paste electrode. Sensor 2 was developed using chitosan in addition to the graphite powder and the multiwall-carbon-nanotubes while sensor 3 was fabricated with the addition of calix[4]arene ionophore. Copper nanoparticles were incorporated in the membrane paste of sensor 4. Sensor 5 was fabricated using a mixture of copper nanoparticles, multiwall-carbon-nanotubes and calix[4]arene in a graphite paste. The studied carbon paste electrodes exhibited the best performance characteristics with slopes of 29.7, 28.8, 30.2, 30.7 and 30.8 (mV / concentration decade) and linear concentration ranges of 1.0 × 10-5 - 1.0 × 10-2, 1.0 × 10-6 - 1.0 × 10-1, 1.0 × 10-7 - 1.0 × 10-2, 1.0 × 10-9 - 1.0 × 10-2 and 1.0 × 10-10 - 1.0 × 10-2 mol L-1for sensors 1, 2, 3, 4 and 5, respectively. The sensors linear ranges deviated from their ideal ranges after 40, 46, 58, 63 and 82 days for sensors 1, 2, 3, 4 and 5, respectively. All the proposed sensors were successfully used for the determination of flupentixol dihydrochloride in bulk, tablets dosage forms and human plasma samples.
doi_str_mv 10.20964/2016.12.04
format article
fullrecord <record><control><sourceid>elsevier_cross</sourceid><recordid>TN_cdi_crossref_primary_10_20964_2016_12_04</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S1452398123179272</els_id><sourcerecordid>S1452398123179272</sourcerecordid><originalsourceid>FETCH-LOGICAL-c316t-2241429032090a078ca73348c18b4b11df640baf953ec6d204da46a2746cfe503</originalsourceid><addsrcrecordid>eNptkF1LwzAUhosoOOau_AO5l80kTdvVu7kPFYYO1OtympyyaNaUJBP7d_ylRqfghbk5gfc5HzxJcs7ohNMyF5ecsnzC-ISKo2TARMbHaTllx3_-p8nI-xcanyhTURSD5OMeWtuBC1oa9OQaPCoyB1fblmzAByRLgzI4q2LaWEfCFskCA7qdbiHoiNmGrMy-wzbod2vIQm975azcGuu0wisy6zqj5YENlmy24HYgcR9XgiGzFkzvtSfQqt_MvuoWY0wew171Z8lJA8bj6KcOk-fV8ml-O14_3NzNZ-uxTFkexpwLJnhJ0yiDAi2mEoo0FVPJprWoGVNNLmgNTZmlKHPFqVAgcuCFyGWDGU2HycVhrnTWe4dN1Tm9A9dXjFbfhqsvwxXjFRWRzg40xpPeNLrKS42tRKVdFFYpq__t-wSVLIJm</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Nanoparticles Based Carbon Paste Electrodes for the Determination of Flupentixol Dihydrochloride: Application to Pharmaceutical Analysis and Pharmacokinetic Study</title><source>ScienceDirect</source><source>Free Full-Text Journals in Chemistry</source><creator>Abdallah, Nehad A.</creator><creatorcontrib>Abdallah, Nehad A.</creatorcontrib><description>Five different carbon paste electrodes were developed and applied for the electrochemical determination of flupentixol dihydrochloride. Sensor 1 was fabricated using a mixture of graphite powder and multiwall-carbon-nanotubes. Different additives were used to improve the performance and the sensitivity of the carbon paste electrode. Sensor 2 was developed using chitosan in addition to the graphite powder and the multiwall-carbon-nanotubes while sensor 3 was fabricated with the addition of calix[4]arene ionophore. Copper nanoparticles were incorporated in the membrane paste of sensor 4. Sensor 5 was fabricated using a mixture of copper nanoparticles, multiwall-carbon-nanotubes and calix[4]arene in a graphite paste. The studied carbon paste electrodes exhibited the best performance characteristics with slopes of 29.7, 28.8, 30.2, 30.7 and 30.8 (mV / concentration decade) and linear concentration ranges of 1.0 × 10-5 - 1.0 × 10-2, 1.0 × 10-6 - 1.0 × 10-1, 1.0 × 10-7 - 1.0 × 10-2, 1.0 × 10-9 - 1.0 × 10-2 and 1.0 × 10-10 - 1.0 × 10-2 mol L-1for sensors 1, 2, 3, 4 and 5, respectively. The sensors linear ranges deviated from their ideal ranges after 40, 46, 58, 63 and 82 days for sensors 1, 2, 3, 4 and 5, respectively. All the proposed sensors were successfully used for the determination of flupentixol dihydrochloride in bulk, tablets dosage forms and human plasma samples.</description><identifier>ISSN: 1452-3981</identifier><identifier>EISSN: 1452-3981</identifier><identifier>DOI: 10.20964/2016.12.04</identifier><language>eng</language><publisher>Elsevier B.V</publisher><subject>copper nanoparticles ; dissolution ; Flupentixol ; multiwall-carbon-nanotubes ; pharmacokinetics</subject><ispartof>International journal of electrochemical science, 2016-12, Vol.11 (12), p.10715-10731</ispartof><rights>2016 The Authors. Published by ESG</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c316t-2241429032090a078ca73348c18b4b11df640baf953ec6d204da46a2746cfe503</citedby><cites>FETCH-LOGICAL-c316t-2241429032090a078ca73348c18b4b11df640baf953ec6d204da46a2746cfe503</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/S1452398123179272$$EHTML$$P50$$Gelsevier$$Hfree_for_read</linktohtml><link.rule.ids>314,780,784,3549,27924,27925,45780</link.rule.ids></links><search><creatorcontrib>Abdallah, Nehad A.</creatorcontrib><title>Nanoparticles Based Carbon Paste Electrodes for the Determination of Flupentixol Dihydrochloride: Application to Pharmaceutical Analysis and Pharmacokinetic Study</title><title>International journal of electrochemical science</title><description>Five different carbon paste electrodes were developed and applied for the electrochemical determination of flupentixol dihydrochloride. Sensor 1 was fabricated using a mixture of graphite powder and multiwall-carbon-nanotubes. Different additives were used to improve the performance and the sensitivity of the carbon paste electrode. Sensor 2 was developed using chitosan in addition to the graphite powder and the multiwall-carbon-nanotubes while sensor 3 was fabricated with the addition of calix[4]arene ionophore. Copper nanoparticles were incorporated in the membrane paste of sensor 4. Sensor 5 was fabricated using a mixture of copper nanoparticles, multiwall-carbon-nanotubes and calix[4]arene in a graphite paste. The studied carbon paste electrodes exhibited the best performance characteristics with slopes of 29.7, 28.8, 30.2, 30.7 and 30.8 (mV / concentration decade) and linear concentration ranges of 1.0 × 10-5 - 1.0 × 10-2, 1.0 × 10-6 - 1.0 × 10-1, 1.0 × 10-7 - 1.0 × 10-2, 1.0 × 10-9 - 1.0 × 10-2 and 1.0 × 10-10 - 1.0 × 10-2 mol L-1for sensors 1, 2, 3, 4 and 5, respectively. The sensors linear ranges deviated from their ideal ranges after 40, 46, 58, 63 and 82 days for sensors 1, 2, 3, 4 and 5, respectively. All the proposed sensors were successfully used for the determination of flupentixol dihydrochloride in bulk, tablets dosage forms and human plasma samples.</description><subject>copper nanoparticles</subject><subject>dissolution</subject><subject>Flupentixol</subject><subject>multiwall-carbon-nanotubes</subject><subject>pharmacokinetics</subject><issn>1452-3981</issn><issn>1452-3981</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2016</creationdate><recordtype>article</recordtype><recordid>eNptkF1LwzAUhosoOOau_AO5l80kTdvVu7kPFYYO1OtympyyaNaUJBP7d_ylRqfghbk5gfc5HzxJcs7ohNMyF5ecsnzC-ISKo2TARMbHaTllx3_-p8nI-xcanyhTURSD5OMeWtuBC1oa9OQaPCoyB1fblmzAByRLgzI4q2LaWEfCFskCA7qdbiHoiNmGrMy-wzbod2vIQm975azcGuu0wisy6zqj5YENlmy24HYgcR9XgiGzFkzvtSfQqt_MvuoWY0wew171Z8lJA8bj6KcOk-fV8ml-O14_3NzNZ-uxTFkexpwLJnhJ0yiDAi2mEoo0FVPJprWoGVNNLmgNTZmlKHPFqVAgcuCFyGWDGU2HycVhrnTWe4dN1Tm9A9dXjFbfhqsvwxXjFRWRzg40xpPeNLrKS42tRKVdFFYpq__t-wSVLIJm</recordid><startdate>20161201</startdate><enddate>20161201</enddate><creator>Abdallah, Nehad A.</creator><general>Elsevier B.V</general><scope>6I.</scope><scope>AAFTH</scope><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>20161201</creationdate><title>Nanoparticles Based Carbon Paste Electrodes for the Determination of Flupentixol Dihydrochloride: Application to Pharmaceutical Analysis and Pharmacokinetic Study</title><author>Abdallah, Nehad A.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c316t-2241429032090a078ca73348c18b4b11df640baf953ec6d204da46a2746cfe503</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2016</creationdate><topic>copper nanoparticles</topic><topic>dissolution</topic><topic>Flupentixol</topic><topic>multiwall-carbon-nanotubes</topic><topic>pharmacokinetics</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Abdallah, Nehad A.</creatorcontrib><collection>ScienceDirect Open Access Titles</collection><collection>Elsevier:ScienceDirect:Open Access</collection><collection>CrossRef</collection><jtitle>International journal of electrochemical science</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Abdallah, Nehad A.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Nanoparticles Based Carbon Paste Electrodes for the Determination of Flupentixol Dihydrochloride: Application to Pharmaceutical Analysis and Pharmacokinetic Study</atitle><jtitle>International journal of electrochemical science</jtitle><date>2016-12-01</date><risdate>2016</risdate><volume>11</volume><issue>12</issue><spage>10715</spage><epage>10731</epage><pages>10715-10731</pages><issn>1452-3981</issn><eissn>1452-3981</eissn><abstract>Five different carbon paste electrodes were developed and applied for the electrochemical determination of flupentixol dihydrochloride. Sensor 1 was fabricated using a mixture of graphite powder and multiwall-carbon-nanotubes. Different additives were used to improve the performance and the sensitivity of the carbon paste electrode. Sensor 2 was developed using chitosan in addition to the graphite powder and the multiwall-carbon-nanotubes while sensor 3 was fabricated with the addition of calix[4]arene ionophore. Copper nanoparticles were incorporated in the membrane paste of sensor 4. Sensor 5 was fabricated using a mixture of copper nanoparticles, multiwall-carbon-nanotubes and calix[4]arene in a graphite paste. The studied carbon paste electrodes exhibited the best performance characteristics with slopes of 29.7, 28.8, 30.2, 30.7 and 30.8 (mV / concentration decade) and linear concentration ranges of 1.0 × 10-5 - 1.0 × 10-2, 1.0 × 10-6 - 1.0 × 10-1, 1.0 × 10-7 - 1.0 × 10-2, 1.0 × 10-9 - 1.0 × 10-2 and 1.0 × 10-10 - 1.0 × 10-2 mol L-1for sensors 1, 2, 3, 4 and 5, respectively. The sensors linear ranges deviated from their ideal ranges after 40, 46, 58, 63 and 82 days for sensors 1, 2, 3, 4 and 5, respectively. All the proposed sensors were successfully used for the determination of flupentixol dihydrochloride in bulk, tablets dosage forms and human plasma samples.</abstract><pub>Elsevier B.V</pub><doi>10.20964/2016.12.04</doi><tpages>17</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 1452-3981
ispartof International journal of electrochemical science, 2016-12, Vol.11 (12), p.10715-10731
issn 1452-3981
1452-3981
language eng
recordid cdi_crossref_primary_10_20964_2016_12_04
source ScienceDirect; Free Full-Text Journals in Chemistry
subjects copper nanoparticles
dissolution
Flupentixol
multiwall-carbon-nanotubes
pharmacokinetics
title Nanoparticles Based Carbon Paste Electrodes for the Determination of Flupentixol Dihydrochloride: Application to Pharmaceutical Analysis and Pharmacokinetic Study
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-07T09%3A32%3A21IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-elsevier_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Nanoparticles%20Based%20Carbon%20Paste%20Electrodes%20for%20the%20Determination%20of%20Flupentixol%20Dihydrochloride:%20Application%20to%20Pharmaceutical%20Analysis%20and%20Pharmacokinetic%20Study&rft.jtitle=International%20journal%20of%20electrochemical%20science&rft.au=Abdallah,%20Nehad%20A.&rft.date=2016-12-01&rft.volume=11&rft.issue=12&rft.spage=10715&rft.epage=10731&rft.pages=10715-10731&rft.issn=1452-3981&rft.eissn=1452-3981&rft_id=info:doi/10.20964/2016.12.04&rft_dat=%3Celsevier_cross%3ES1452398123179272%3C/elsevier_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c316t-2241429032090a078ca73348c18b4b11df640baf953ec6d204da46a2746cfe503%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true