Wet air oxidation: kinetics of reaction, carbon dioxide equilibrium and reactor design - an overview

Aqueous wastes containing organic pollutants can be efficiently treated by wet air oxidation (WAO), i.e. oxidation by molecular oxygen in the liquid phase, under high temperature (200 to 325°C) and pressure (up to 150 bar). In western Europe, only an handful of industrial plants are in operation. Mo...

Full description

Saved in:
Bibliographic Details
Published in:Water science and technology 1997-02, Vol.35 (4), p.111-118
Main Authors: Debellefontaine, H., Cammas, F. X., Deiber, G., Foussard, J. N., Reilhac, P.
Format: Article
Language:English
Citations: Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c167t-ac1501e2c70f1d1b605b800e9ff88bb489a6d94467d815a3a569c1748b987df23
cites
container_end_page 118
container_issue 4
container_start_page 111
container_title Water science and technology
container_volume 35
creator Debellefontaine, H.
Cammas, F. X.
Deiber, G.
Foussard, J. N.
Reilhac, P.
description Aqueous wastes containing organic pollutants can be efficiently treated by wet air oxidation (WAO), i.e. oxidation by molecular oxygen in the liquid phase, under high temperature (200 to 325°C) and pressure (up to 150 bar). In western Europe, only an handful of industrial plants are in operation. Most of them were designed by extrapolating results from pilot plants. Only a very few studies have been devoted to the scientific design of such reactors (bubble columns). This paper discusses what needs to be known for this scientific design. The usual design methods assume that the column is divided into a number of cells. Each cell is a perfectly mixed reactor connected with the contiguous cells. Reliable data and models are available for hydrodynamics (axial dispersion, gas hold up) and mass transfer. Data are also needed for the kinetics of chemical reactions and are available from numerous sources, but have not yet been generalised. The thermodynamics (fugacities and enthalpy) of the gas phase can be determined with the Peng Robinson equation of state, and the Henry law for the solubility of gases in water describes the equilibrium conditions. But additional data are needed for water solutions containing salts. This paper describes a method that allows such a determination to be made by establishing rigorous balances on a batch autoclave. At present, these data are being used to implement a computer program aimed at determining the performance of a wet air oxidation reactor depending on the various operating parameters. Some typical profiles within the reactor are presented, establishing that the pH of the solution is a very important parameter.
doi_str_mv 10.2166/wst.1997.0098
format article
fullrecord <record><control><sourceid>crossref</sourceid><recordid>TN_cdi_crossref_primary_10_2166_wst_1997_0098</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>10_2166_wst_1997_0098</sourcerecordid><originalsourceid>FETCH-LOGICAL-c167t-ac1501e2c70f1d1b605b800e9ff88bb489a6d94467d815a3a569c1748b987df23</originalsourceid><addsrcrecordid>eNotkEtLAzEYRYMoOFaX7vMDTP2SzOThToovKLhRXA55SrSdaDJt9d_boa7u5XK4i4PQJYU5o0Jc7-o4p1rLOYBWR6jZd0G05OwYNcAkJ5QxforOav0AAMlbaJB_CyM2qeD8k7wZUx5u8GcawphcxTniEoyb1ivsTLF5wD5NZMDhe5NWyZa0WWMz-AOYC_ahpvcBk_2I8zaUbQq7c3QSzaqGi_-codf7u5fFI1k-PzwtbpfEUSFHYhztgAbmJETqqRXQWQUQdIxKWdsqbYTXbSukV7Qz3HRCOypbZbWSPjI-Q-Tw60qutYTYf5W0NuW3p9BPivq9on5S1E-K-B-chFsh</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Wet air oxidation: kinetics of reaction, carbon dioxide equilibrium and reactor design - an overview</title><source>Alma/SFX Local Collection</source><creator>Debellefontaine, H. ; Cammas, F. X. ; Deiber, G. ; Foussard, J. N. ; Reilhac, P.</creator><creatorcontrib>Debellefontaine, H. ; Cammas, F. X. ; Deiber, G. ; Foussard, J. N. ; Reilhac, P.</creatorcontrib><description>Aqueous wastes containing organic pollutants can be efficiently treated by wet air oxidation (WAO), i.e. oxidation by molecular oxygen in the liquid phase, under high temperature (200 to 325°C) and pressure (up to 150 bar). In western Europe, only an handful of industrial plants are in operation. Most of them were designed by extrapolating results from pilot plants. Only a very few studies have been devoted to the scientific design of such reactors (bubble columns). This paper discusses what needs to be known for this scientific design. The usual design methods assume that the column is divided into a number of cells. Each cell is a perfectly mixed reactor connected with the contiguous cells. Reliable data and models are available for hydrodynamics (axial dispersion, gas hold up) and mass transfer. Data are also needed for the kinetics of chemical reactions and are available from numerous sources, but have not yet been generalised. The thermodynamics (fugacities and enthalpy) of the gas phase can be determined with the Peng Robinson equation of state, and the Henry law for the solubility of gases in water describes the equilibrium conditions. But additional data are needed for water solutions containing salts. This paper describes a method that allows such a determination to be made by establishing rigorous balances on a batch autoclave. At present, these data are being used to implement a computer program aimed at determining the performance of a wet air oxidation reactor depending on the various operating parameters. Some typical profiles within the reactor are presented, establishing that the pH of the solution is a very important parameter.</description><identifier>ISSN: 0273-1223</identifier><identifier>EISSN: 1996-9732</identifier><identifier>DOI: 10.2166/wst.1997.0098</identifier><language>eng</language><ispartof>Water science and technology, 1997-02, Vol.35 (4), p.111-118</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c167t-ac1501e2c70f1d1b605b800e9ff88bb489a6d94467d815a3a569c1748b987df23</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27901,27902</link.rule.ids></links><search><creatorcontrib>Debellefontaine, H.</creatorcontrib><creatorcontrib>Cammas, F. X.</creatorcontrib><creatorcontrib>Deiber, G.</creatorcontrib><creatorcontrib>Foussard, J. N.</creatorcontrib><creatorcontrib>Reilhac, P.</creatorcontrib><title>Wet air oxidation: kinetics of reaction, carbon dioxide equilibrium and reactor design - an overview</title><title>Water science and technology</title><description>Aqueous wastes containing organic pollutants can be efficiently treated by wet air oxidation (WAO), i.e. oxidation by molecular oxygen in the liquid phase, under high temperature (200 to 325°C) and pressure (up to 150 bar). In western Europe, only an handful of industrial plants are in operation. Most of them were designed by extrapolating results from pilot plants. Only a very few studies have been devoted to the scientific design of such reactors (bubble columns). This paper discusses what needs to be known for this scientific design. The usual design methods assume that the column is divided into a number of cells. Each cell is a perfectly mixed reactor connected with the contiguous cells. Reliable data and models are available for hydrodynamics (axial dispersion, gas hold up) and mass transfer. Data are also needed for the kinetics of chemical reactions and are available from numerous sources, but have not yet been generalised. The thermodynamics (fugacities and enthalpy) of the gas phase can be determined with the Peng Robinson equation of state, and the Henry law for the solubility of gases in water describes the equilibrium conditions. But additional data are needed for water solutions containing salts. This paper describes a method that allows such a determination to be made by establishing rigorous balances on a batch autoclave. At present, these data are being used to implement a computer program aimed at determining the performance of a wet air oxidation reactor depending on the various operating parameters. Some typical profiles within the reactor are presented, establishing that the pH of the solution is a very important parameter.</description><issn>0273-1223</issn><issn>1996-9732</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1997</creationdate><recordtype>article</recordtype><recordid>eNotkEtLAzEYRYMoOFaX7vMDTP2SzOThToovKLhRXA55SrSdaDJt9d_boa7u5XK4i4PQJYU5o0Jc7-o4p1rLOYBWR6jZd0G05OwYNcAkJ5QxforOav0AAMlbaJB_CyM2qeD8k7wZUx5u8GcawphcxTniEoyb1ivsTLF5wD5NZMDhe5NWyZa0WWMz-AOYC_ahpvcBk_2I8zaUbQq7c3QSzaqGi_-codf7u5fFI1k-PzwtbpfEUSFHYhztgAbmJETqqRXQWQUQdIxKWdsqbYTXbSukV7Qz3HRCOypbZbWSPjI-Q-Tw60qutYTYf5W0NuW3p9BPivq9on5S1E-K-B-chFsh</recordid><startdate>19970201</startdate><enddate>19970201</enddate><creator>Debellefontaine, H.</creator><creator>Cammas, F. X.</creator><creator>Deiber, G.</creator><creator>Foussard, J. N.</creator><creator>Reilhac, P.</creator><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>19970201</creationdate><title>Wet air oxidation: kinetics of reaction, carbon dioxide equilibrium and reactor design - an overview</title><author>Debellefontaine, H. ; Cammas, F. X. ; Deiber, G. ; Foussard, J. N. ; Reilhac, P.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c167t-ac1501e2c70f1d1b605b800e9ff88bb489a6d94467d815a3a569c1748b987df23</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1997</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Debellefontaine, H.</creatorcontrib><creatorcontrib>Cammas, F. X.</creatorcontrib><creatorcontrib>Deiber, G.</creatorcontrib><creatorcontrib>Foussard, J. N.</creatorcontrib><creatorcontrib>Reilhac, P.</creatorcontrib><collection>CrossRef</collection><jtitle>Water science and technology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Debellefontaine, H.</au><au>Cammas, F. X.</au><au>Deiber, G.</au><au>Foussard, J. N.</au><au>Reilhac, P.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Wet air oxidation: kinetics of reaction, carbon dioxide equilibrium and reactor design - an overview</atitle><jtitle>Water science and technology</jtitle><date>1997-02-01</date><risdate>1997</risdate><volume>35</volume><issue>4</issue><spage>111</spage><epage>118</epage><pages>111-118</pages><issn>0273-1223</issn><eissn>1996-9732</eissn><abstract>Aqueous wastes containing organic pollutants can be efficiently treated by wet air oxidation (WAO), i.e. oxidation by molecular oxygen in the liquid phase, under high temperature (200 to 325°C) and pressure (up to 150 bar). In western Europe, only an handful of industrial plants are in operation. Most of them were designed by extrapolating results from pilot plants. Only a very few studies have been devoted to the scientific design of such reactors (bubble columns). This paper discusses what needs to be known for this scientific design. The usual design methods assume that the column is divided into a number of cells. Each cell is a perfectly mixed reactor connected with the contiguous cells. Reliable data and models are available for hydrodynamics (axial dispersion, gas hold up) and mass transfer. Data are also needed for the kinetics of chemical reactions and are available from numerous sources, but have not yet been generalised. The thermodynamics (fugacities and enthalpy) of the gas phase can be determined with the Peng Robinson equation of state, and the Henry law for the solubility of gases in water describes the equilibrium conditions. But additional data are needed for water solutions containing salts. This paper describes a method that allows such a determination to be made by establishing rigorous balances on a batch autoclave. At present, these data are being used to implement a computer program aimed at determining the performance of a wet air oxidation reactor depending on the various operating parameters. Some typical profiles within the reactor are presented, establishing that the pH of the solution is a very important parameter.</abstract><doi>10.2166/wst.1997.0098</doi><tpages>8</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0273-1223
ispartof Water science and technology, 1997-02, Vol.35 (4), p.111-118
issn 0273-1223
1996-9732
language eng
recordid cdi_crossref_primary_10_2166_wst_1997_0098
source Alma/SFX Local Collection
title Wet air oxidation: kinetics of reaction, carbon dioxide equilibrium and reactor design - an overview
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-28T13%3A59%3A46IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-crossref&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Wet%20air%20oxidation:%20kinetics%20of%20reaction,%20carbon%20dioxide%20equilibrium%20and%20reactor%20design%20-%20an%20overview&rft.jtitle=Water%20science%20and%20technology&rft.au=Debellefontaine,%20H.&rft.date=1997-02-01&rft.volume=35&rft.issue=4&rft.spage=111&rft.epage=118&rft.pages=111-118&rft.issn=0273-1223&rft.eissn=1996-9732&rft_id=info:doi/10.2166/wst.1997.0098&rft_dat=%3Ccrossref%3E10_2166_wst_1997_0098%3C/crossref%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c167t-ac1501e2c70f1d1b605b800e9ff88bb489a6d94467d815a3a569c1748b987df23%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true