Full-scale pressure vessel tests at low temperatures and external electric potential

The internal pressure test method and test results are presented for pressure vessels at a low-temperature and applied external electric potential conditions. The rupture mechanisms, plasticity and crack resistance characteristics, and times until rupture (rupture lifetimes) are compared between the...

Full description

Saved in:
Bibliographic Details
Published in:Journal of machinery manufacture and reliability 2015-01, Vol.44 (1), p.94-97
Main Authors: Matvienko, Yu. G., Bolshakov, A. M., Burnashev, A. V.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:The internal pressure test method and test results are presented for pressure vessels at a low-temperature and applied external electric potential conditions. The rupture mechanisms, plasticity and crack resistance characteristics, and times until rupture (rupture lifetimes) are compared between the tested pressure vessels and vessels exposed to a constant external electric potential. The positive effect of the external electric potential on the process of rupture of pressure vessels is noted.