Loading…

Infants' detection of increments in low- and high-frequency noise

A visually reinforced operant paradigm was employed to examine the relationship between the difference limen (DL) for intensity and level of the standard during infancy. In Experiment 1, 7-month-old infants and adults detected increments in continuous noise presented via headphones at each of four l...

Full description

Saved in:
Bibliographic Details
Published in:Perception & psychophysics 1998-08, Vol.60 (6), p.1044-1051
Main Authors: BERG, K. M, BOSWELL, A. E
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:A visually reinforced operant paradigm was employed to examine the relationship between the difference limen (DL) for intensity and level of the standard during infancy. In Experiment 1, 7-month-old infants and adults detected increments in continuous noise presented via headphones at each of four levels ranging from 28 to 58 dB SPL. Noise stimuli were 2-octave bands centered at either 400 or 4000 Hz, and increments were 10 and 100 msec in duration. Infants' DLs were significantly larger than those of adult subjects and significantly larger for low- than for high-frequency stimuli. For the high-frequency noise band, infants' DLs were generally consistent with Weber's law, remaining essentially constant for standards higher than 28 dB SPL (3 dB SL) for 100-msec increments and 38 dB SPL (13 dB SL) for 10-msec increments. For low-frequency noise, infants' absolute thresholds were exceptionally high, and sensation levels of the standards were too low to adequately describe the relationship. In Experiment 2, 7-month-old infants detected 10- and 100-msec increments in 400-Hz noise stimuli presented in sound field. Infants' low-frequency DLs were large at low intensities and decreased with increases in level of the standard up to at least 30 dB SL. For both low- and high-frequency noise, the difference between DLs for 10- and 100-msec increments tended to be large at low levels of the standard and to decrease at higher levels. These results suggest that the relationship between the DL and level of the standard varies with both stimulus frequency and duration during infancy. However, stimulus-dependent immaturities in increment detection may be most evident at levels within approximately 30 dB of absolute threshold.
ISSN:0031-5117
1532-5962
DOI:10.3758/BF03211938