A sensitive assay for ZYAN1 in human whole blood and urine utilizing positive LC-MS/MS electrospray ionization
: A sensitive LC-MS/MS method was developed and validated for estimation of ZYAN1 in human blood/urine. : An analog internal standard IOX2 along with ZYAN1 was quantified using selective reaction monitoring in positive mode. The chromatographic separation was performed by gradient elution with C ana...
Saved in:
Published in: | Bioanalysis 2017-05, Vol.9 (9), p.719-732 |
---|---|
Main Authors: | , , , , , , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | : A sensitive LC-MS/MS method was developed and validated for estimation of ZYAN1 in human blood/urine.
: An analog internal standard IOX2 along with ZYAN1 was quantified using selective reaction monitoring in positive mode. The chromatographic separation was performed by gradient elution with C
analytical column (3 µm, 50 mm × 2.0 mm) with 4-min run time using an acidified mobile phase consisting of ammonium formate and acetonitrile. Protein precipitation enabled extraction of analytes from diluted blood/urine.
: Calibration curve of ZYAN1 was linear (2-5000 ng/ml). The recovery of ZYAN1 and IOX2 was between 87 and 104%. Interday and intraday accuracy and precision was found well within the acceptance criteria.
: The validated assay was applied for clinical pharmacokinetics of ZYAN1 in healthy volunteers. |
---|---|