Thoughts on the Possibility of Damage of High-Voltage Electrical Insulation below the So-Called Inception Voltage: Simulation under a Superposition of AC and DC Voltage – Part III

In a previous work, a typical case is studied, where a solid sheet insulation contains a void under DC or AC voltage. In the present paper, to study the charging phenomenon in HVDC valve windings and cables, a more complex case is studied under a superposition of AC and DC voltage. Real inception vo...

Full description

Saved in:
Bibliographic Details
Published in:Engineering, technology & applied science research technology & applied science research, 2018-08, Vol.8 (4), p.3088-3092
Main Author: Danikas, M.
Format: Article
Language:English
Citations: Items that this one cites
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:In a previous work, a typical case is studied, where a solid sheet insulation contains a void under DC or AC voltage. In the present paper, to study the charging phenomenon in HVDC valve windings and cables, a more complex case is studied under a superposition of AC and DC voltage. Real inception voltage is calculated, and it agrees with the experimental results reported in another paper. Moreover, the location of the charging phenomenon is calculated, and it is related to the ratio between AC and DC voltage.