Loading…

Flexural Strength of Reinforced Concrete RAC Beams Exposed to 6-hour Fire – Part 2: Rich Mix

In this research work, experimental investigation on flexural strength of reinforced concrete beams exposed to fire for 6-hours at the temperature of 1000˚C is presented. The beams are made with 50% replacement of natural coarse aggregates with recyclable concrete aggregates. A total of 12 reinforce...

Full description

Saved in:
Bibliographic Details
Published in:Engineering, technology & applied science research technology & applied science research, 2019-02, Vol.9 (1), p.3814-3817
Main Authors: Buller, A. H., Oad, M., Memon, B. A.
Format: Article
Language:English
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:In this research work, experimental investigation on flexural strength of reinforced concrete beams exposed to fire for 6-hours at the temperature of 1000˚C is presented. The beams are made with 50% replacement of natural coarse aggregates with recyclable concrete aggregates. A total of 12 reinforced concrete beams using 1:1.5:3 mix (rich mix) and 0.54 water-cement ratio were cast. The beams were prepared in two groups. Group 1 beams were prepared with 50% recyclable aggregates, whereas group 2 beams were cast with all-natural aggregates (control specimens). All beams were exposed to fire at the above-mentioned temperature followed by testing in universal load testing machine under central point load. Comparison of the results reveals that proposed beams show comparable resistance even after exposed to 6-hours fire at 1000°C.
ISSN:2241-4487
1792-8036