How internal heat loads of buildings affect the effectiveness of vertical greenery systems? An experimental study

Nature-based solutions applied to the building skin, such as green roofs and vertical greenery systems, are standing out as the most promising by contributing with thermal improvements at building scale. From previous research done by GREiA research group at the University of Lleida (Spain), energy...

Full description

Saved in:
Bibliographic Details
Published in:Renewable energy 2020-05, Vol.151, p.919-930
Main Authors: Coma, Julià, Chàfer, Marta, Pérez, Gabriel, Cabeza, Luisa F.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c394t-6a1a34ab67ca43135cae1a59731a90df606b5ee8e6bc95e06fe104cc3dfabede3
cites cdi_FETCH-LOGICAL-c394t-6a1a34ab67ca43135cae1a59731a90df606b5ee8e6bc95e06fe104cc3dfabede3
container_end_page 930
container_issue
container_start_page 919
container_title Renewable energy
container_volume 151
creator Coma, Julià
Chàfer, Marta
Pérez, Gabriel
Cabeza, Luisa F.
description Nature-based solutions applied to the building skin, such as green roofs and vertical greenery systems, are standing out as the most promising by contributing with thermal improvements at building scale. From previous research done by GREiA research group at the University of Lleida (Spain), energy savings up to 58% were obtained by implementing vertical greenery systems on external building walls for cooling purposes. However, since there exist other passive and active energy saving technologies in the literature review that were limited their cooling and heating capacity after implementing internal heat loads, new experimental tests for two different vertical greenery systems simulating the heat loads in both, summer and winter were conducted in this research. Additionally, these experiments also improve the scarce and controversial literature for winter conditions. The results demonstrated that considering internal loads in experimental investigations is crucial for the results of the effectiveness of the green walls and green facades. The energy savings of VGS were reduced between 22.5% and 26.7% because of the internal loads for cooling purposes, and increased about 3.6% and 3.1% for heating. •Seasonal energy analysis of two vertical greenery systems implemented in buildings.•Experimental study of VGS considering internal heat loads generated by occupancy.•The thermal performance of VGS decreased due to internal heat loads.•During cooling periods there is still large energy saving potential by VGS.•VGS provide high thermal stability in summer but also in winter periods.
doi_str_mv 10.1016/j.renene.2019.11.077
format article
fullrecord <record><control><sourceid>csuc_cross</sourceid><recordid>TN_cdi_csuc_recercat_oai_recercat_cat_2072_371663</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0960148119317707</els_id><sourcerecordid>oai_recercat_cat_2072_371663</sourcerecordid><originalsourceid>FETCH-LOGICAL-c394t-6a1a34ab67ca43135cae1a59731a90df606b5ee8e6bc95e06fe104cc3dfabede3</originalsourceid><addsrcrecordid>eNp9kM9OwzAMxiMEEmPwBhzyAi1x06btBTRNwJAmcYFzlKbOlmlrR5IN-vZkfyRuKLJiR_59dj5C7oGlwEA8rFKHXTxpxqBOAVJWlhdkBFVZJ0xU2SUZsVqwBPIKrsmN9yvGoKjKfES-Zv03tV1A16k1XaIKdN2r1tPe0GZn163tFp4qY1AHGpZI8ZjafRznj117dMHqCC8cxkc3UD_4gBv_RCcdxZ8tOrvBLsQOH3btcEuujFp7vDvfY_L58vwxnSXz99e36WSeaF7nIREKFM9VI0qtcg680ApBFXXJQdWsNYKJpkCsUDS6LpAJg8ByrXlrVIMt8jGBk672Oy0danRaBdkr-1ccImNlJnkJQvDI5GfG9d47NHIbl1dukMDkwWq5kier5cFqCSCj1RF7PGEY_7O36KTXFjuNrY2jgmx7-7_AL6nPjRM</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>How internal heat loads of buildings affect the effectiveness of vertical greenery systems? An experimental study</title><source>Elsevier</source><creator>Coma, Julià ; Chàfer, Marta ; Pérez, Gabriel ; Cabeza, Luisa F.</creator><creatorcontrib>Coma, Julià ; Chàfer, Marta ; Pérez, Gabriel ; Cabeza, Luisa F.</creatorcontrib><description>Nature-based solutions applied to the building skin, such as green roofs and vertical greenery systems, are standing out as the most promising by contributing with thermal improvements at building scale. From previous research done by GREiA research group at the University of Lleida (Spain), energy savings up to 58% were obtained by implementing vertical greenery systems on external building walls for cooling purposes. However, since there exist other passive and active energy saving technologies in the literature review that were limited their cooling and heating capacity after implementing internal heat loads, new experimental tests for two different vertical greenery systems simulating the heat loads in both, summer and winter were conducted in this research. Additionally, these experiments also improve the scarce and controversial literature for winter conditions. The results demonstrated that considering internal loads in experimental investigations is crucial for the results of the effectiveness of the green walls and green facades. The energy savings of VGS were reduced between 22.5% and 26.7% because of the internal loads for cooling purposes, and increased about 3.6% and 3.1% for heating. •Seasonal energy analysis of two vertical greenery systems implemented in buildings.•Experimental study of VGS considering internal heat loads generated by occupancy.•The thermal performance of VGS decreased due to internal heat loads.•During cooling periods there is still large energy saving potential by VGS.•VGS provide high thermal stability in summer but also in winter periods.</description><identifier>ISSN: 0960-1481</identifier><identifier>EISSN: 1879-0682</identifier><identifier>DOI: 10.1016/j.renene.2019.11.077</identifier><language>eng</language><publisher>Elsevier Ltd</publisher><subject>Arquitectura ; Buildings ; Edificis ; Energy conservation ; Estalvi d'energia ; Internal heat loads ; Jardins verticals ; Occupancy ; Passive energy savings ; Vertical gardening ; Vertical greenery systems ; Àrees temàtiques de la UPC</subject><ispartof>Renewable energy, 2020-05, Vol.151, p.919-930</ispartof><rights>2019 Elsevier Ltd</rights><rights>info:eu-repo/semantics/openAccess</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c394t-6a1a34ab67ca43135cae1a59731a90df606b5ee8e6bc95e06fe104cc3dfabede3</citedby><cites>FETCH-LOGICAL-c394t-6a1a34ab67ca43135cae1a59731a90df606b5ee8e6bc95e06fe104cc3dfabede3</cites><orcidid>0000-0002-1750-661X ; 0000-0002-4440-5312 ; 0000-0001-5086-872X</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>230,314,780,784,885,27924,27925</link.rule.ids></links><search><creatorcontrib>Coma, Julià</creatorcontrib><creatorcontrib>Chàfer, Marta</creatorcontrib><creatorcontrib>Pérez, Gabriel</creatorcontrib><creatorcontrib>Cabeza, Luisa F.</creatorcontrib><title>How internal heat loads of buildings affect the effectiveness of vertical greenery systems? An experimental study</title><title>Renewable energy</title><description>Nature-based solutions applied to the building skin, such as green roofs and vertical greenery systems, are standing out as the most promising by contributing with thermal improvements at building scale. From previous research done by GREiA research group at the University of Lleida (Spain), energy savings up to 58% were obtained by implementing vertical greenery systems on external building walls for cooling purposes. However, since there exist other passive and active energy saving technologies in the literature review that were limited their cooling and heating capacity after implementing internal heat loads, new experimental tests for two different vertical greenery systems simulating the heat loads in both, summer and winter were conducted in this research. Additionally, these experiments also improve the scarce and controversial literature for winter conditions. The results demonstrated that considering internal loads in experimental investigations is crucial for the results of the effectiveness of the green walls and green facades. The energy savings of VGS were reduced between 22.5% and 26.7% because of the internal loads for cooling purposes, and increased about 3.6% and 3.1% for heating. •Seasonal energy analysis of two vertical greenery systems implemented in buildings.•Experimental study of VGS considering internal heat loads generated by occupancy.•The thermal performance of VGS decreased due to internal heat loads.•During cooling periods there is still large energy saving potential by VGS.•VGS provide high thermal stability in summer but also in winter periods.</description><subject>Arquitectura</subject><subject>Buildings</subject><subject>Edificis</subject><subject>Energy conservation</subject><subject>Estalvi d'energia</subject><subject>Internal heat loads</subject><subject>Jardins verticals</subject><subject>Occupancy</subject><subject>Passive energy savings</subject><subject>Vertical gardening</subject><subject>Vertical greenery systems</subject><subject>Àrees temàtiques de la UPC</subject><issn>0960-1481</issn><issn>1879-0682</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2020</creationdate><recordtype>article</recordtype><recordid>eNp9kM9OwzAMxiMEEmPwBhzyAi1x06btBTRNwJAmcYFzlKbOlmlrR5IN-vZkfyRuKLJiR_59dj5C7oGlwEA8rFKHXTxpxqBOAVJWlhdkBFVZJ0xU2SUZsVqwBPIKrsmN9yvGoKjKfES-Zv03tV1A16k1XaIKdN2r1tPe0GZn163tFp4qY1AHGpZI8ZjafRznj117dMHqCC8cxkc3UD_4gBv_RCcdxZ8tOrvBLsQOH3btcEuujFp7vDvfY_L58vwxnSXz99e36WSeaF7nIREKFM9VI0qtcg680ApBFXXJQdWsNYKJpkCsUDS6LpAJg8ByrXlrVIMt8jGBk672Oy0danRaBdkr-1ccImNlJnkJQvDI5GfG9d47NHIbl1dukMDkwWq5kier5cFqCSCj1RF7PGEY_7O36KTXFjuNrY2jgmx7-7_AL6nPjRM</recordid><startdate>20200501</startdate><enddate>20200501</enddate><creator>Coma, Julià</creator><creator>Chàfer, Marta</creator><creator>Pérez, Gabriel</creator><creator>Cabeza, Luisa F.</creator><general>Elsevier Ltd</general><scope>AAYXX</scope><scope>CITATION</scope><scope>XX2</scope><orcidid>https://orcid.org/0000-0002-1750-661X</orcidid><orcidid>https://orcid.org/0000-0002-4440-5312</orcidid><orcidid>https://orcid.org/0000-0001-5086-872X</orcidid></search><sort><creationdate>20200501</creationdate><title>How internal heat loads of buildings affect the effectiveness of vertical greenery systems? An experimental study</title><author>Coma, Julià ; Chàfer, Marta ; Pérez, Gabriel ; Cabeza, Luisa F.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c394t-6a1a34ab67ca43135cae1a59731a90df606b5ee8e6bc95e06fe104cc3dfabede3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2020</creationdate><topic>Arquitectura</topic><topic>Buildings</topic><topic>Edificis</topic><topic>Energy conservation</topic><topic>Estalvi d'energia</topic><topic>Internal heat loads</topic><topic>Jardins verticals</topic><topic>Occupancy</topic><topic>Passive energy savings</topic><topic>Vertical gardening</topic><topic>Vertical greenery systems</topic><topic>Àrees temàtiques de la UPC</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Coma, Julià</creatorcontrib><creatorcontrib>Chàfer, Marta</creatorcontrib><creatorcontrib>Pérez, Gabriel</creatorcontrib><creatorcontrib>Cabeza, Luisa F.</creatorcontrib><collection>CrossRef</collection><collection>Recercat</collection><jtitle>Renewable energy</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Coma, Julià</au><au>Chàfer, Marta</au><au>Pérez, Gabriel</au><au>Cabeza, Luisa F.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>How internal heat loads of buildings affect the effectiveness of vertical greenery systems? An experimental study</atitle><jtitle>Renewable energy</jtitle><date>2020-05-01</date><risdate>2020</risdate><volume>151</volume><spage>919</spage><epage>930</epage><pages>919-930</pages><issn>0960-1481</issn><eissn>1879-0682</eissn><abstract>Nature-based solutions applied to the building skin, such as green roofs and vertical greenery systems, are standing out as the most promising by contributing with thermal improvements at building scale. From previous research done by GREiA research group at the University of Lleida (Spain), energy savings up to 58% were obtained by implementing vertical greenery systems on external building walls for cooling purposes. However, since there exist other passive and active energy saving technologies in the literature review that were limited their cooling and heating capacity after implementing internal heat loads, new experimental tests for two different vertical greenery systems simulating the heat loads in both, summer and winter were conducted in this research. Additionally, these experiments also improve the scarce and controversial literature for winter conditions. The results demonstrated that considering internal loads in experimental investigations is crucial for the results of the effectiveness of the green walls and green facades. The energy savings of VGS were reduced between 22.5% and 26.7% because of the internal loads for cooling purposes, and increased about 3.6% and 3.1% for heating. •Seasonal energy analysis of two vertical greenery systems implemented in buildings.•Experimental study of VGS considering internal heat loads generated by occupancy.•The thermal performance of VGS decreased due to internal heat loads.•During cooling periods there is still large energy saving potential by VGS.•VGS provide high thermal stability in summer but also in winter periods.</abstract><pub>Elsevier Ltd</pub><doi>10.1016/j.renene.2019.11.077</doi><tpages>12</tpages><orcidid>https://orcid.org/0000-0002-1750-661X</orcidid><orcidid>https://orcid.org/0000-0002-4440-5312</orcidid><orcidid>https://orcid.org/0000-0001-5086-872X</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0960-1481
ispartof Renewable energy, 2020-05, Vol.151, p.919-930
issn 0960-1481
1879-0682
language eng
recordid cdi_csuc_recercat_oai_recercat_cat_2072_371663
source Elsevier
subjects Arquitectura
Buildings
Edificis
Energy conservation
Estalvi d'energia
Internal heat loads
Jardins verticals
Occupancy
Passive energy savings
Vertical gardening
Vertical greenery systems
Àrees temàtiques de la UPC
title How internal heat loads of buildings affect the effectiveness of vertical greenery systems? An experimental study
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-07T21%3A42%3A00IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-csuc_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=How%20internal%20heat%20loads%20of%20buildings%20affect%20the%20effectiveness%20of%20vertical%20greenery%20systems?%20An%20experimental%20study&rft.jtitle=Renewable%20energy&rft.au=Coma,%20Juli%C3%A0&rft.date=2020-05-01&rft.volume=151&rft.spage=919&rft.epage=930&rft.pages=919-930&rft.issn=0960-1481&rft.eissn=1879-0682&rft_id=info:doi/10.1016/j.renene.2019.11.077&rft_dat=%3Ccsuc_cross%3Eoai_recercat_cat_2072_371663%3C/csuc_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c394t-6a1a34ab67ca43135cae1a59731a90df606b5ee8e6bc95e06fe104cc3dfabede3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true