Loading…
A STUDY ON THE COMPARISON OF SAFETY AND EFFICACY OF POST PARTUM INTRAUTERINE CONTRACEPTIVE DEVICE WITH INTERVAL INTRAUTERINE CONTRACEPTIVE DEVICE
ABSTRACT Objective: To compare the safety and efficacy of post partum intrauterine contraceptive device with interval intrauterine contraceptive device, to avoid unplanned pregnancies. Study Design: Quasi-experimental study. Place and Duration of Study: Gynaecology and Obstetrics Department, Combine...
Saved in:
Published in: | Pakistan Armed Forces medical journal 2020-10, Vol.70 (5), p.1419-1423 |
---|---|
Main Authors: | , , , |
Format: | Article |
Language: | English |
Subjects: | |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | |
---|---|
cites | |
container_end_page | 1423 |
container_issue | 5 |
container_start_page | 1419 |
container_title | Pakistan Armed Forces medical journal |
container_volume | 70 |
creator | Arif, Nadia Zafar, Bushra Raja Qaseem Ahmed Farrukh Shehzad |
description | ABSTRACT Objective: To compare the safety and efficacy of post partum intrauterine contraceptive device with interval intrauterine contraceptive device, to avoid unplanned pregnancies. Study Design: Quasi-experimental study. Place and Duration of Study: Gynaecology and Obstetrics Department, Combined Military Hospital (CMH) Okara, from Aug 2019 to Jul 2020 Methodology: One hundred patients were included in the study. Divided in 2 groups, group A (post partum intrauterine contraceptive device, n=50) patients underwent cesarean section under spinal anesthesia, after removal of placenta and membranes contraceptive device was placed near fundus with fingers and incision was closed. In group B (interval intrauterine contraceptive device, n=50) and intrauterine contraceptive device was placed 6 weeks postpartum. Post insertion follow up was at 6 weeks and then 6 months. Efficacy was assessed by the continuation rate and safety, by presence or otherwise of heavy menstrual bleeding, lost threads, abnormal vaginal discharge and pain abdomen on follow up visits. Results: Efficacy in group A was 46 (92%) and in group B 40 (80%). Safety that is heavy menstrual bleeding 3 (6%) and 5 (10%), lost threads 3 (6%) and 1 (2%), abnormal vaginal discharge 2 (4%), and 3 (6%), and pain abdomen 1 (2%) and 2 (4%) in groups A and B respectively. Conclusion: Postpartum intrauterine contraceptive device insertion was found to be effective and safe method as compared to interval intrauterine contraceptive device. Successful placement, continuation and retention rate were significantly higher in post placental intra uterine contraceptive device insertion. |
format | article |
fullrecord | <record><control><sourceid>gale_doaj_</sourceid><recordid>TN_cdi_doaj_primary_oai_doaj_org_article_021b065d8e0e4c3a9a9ae7b28cfc2630</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><galeid>A641760550</galeid><doaj_id>oai_doaj_org_article_021b065d8e0e4c3a9a9ae7b28cfc2630</doaj_id><sourcerecordid>A641760550</sourcerecordid><originalsourceid>FETCH-LOGICAL-d231t-5a6616d58b4cbb29005bb70509234ada6ce55c3803da0e99680b61567ff6ca063</originalsourceid><addsrcrecordid>eNqFj89Kw0AQxoMoWKrvsOA5Mtl_2RxDurWBNintttJT2Gw2kmKbmtSDj-Ebu1FBD4Izh2E-vvnxzYU3wjQIfCEovvRGAAT8iFNx7d32_R5cMYIpsJH3HqO12kx2KM-QmkmU5ItlvErXbs2naB1PpdqhOJsgOZ2mSZzsBnmZrxVyNrVZoDRTq3ij5CrNhuthS-RSpVuJJnKbJhI9pmo22ORqG8__9994V7V-7u3t9xx7Gxcimfnz_MElmPsVJsHZZ5rzgFdMlNSUJY7cS2UZAoMIE6orzY1lzBABpNJgo4gLKHnAeFjX3GjgZOylX9yq1fvi1DUH3b0VrW6KT6HtngrdnRvzbAvAQQmcVcKCpYboyLUNSyxMbTAn4Fh3X6xT17682v5c7NvX7ujiF5iGJAQBnP64nrSDNse6PXfaHJreFDGnQciBsYF1_4fLdWUPjWmPtm6c_uvgA-wkilk</addsrcrecordid><sourcetype>Open Website</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2473708064</pqid></control><display><type>article</type><title>A STUDY ON THE COMPARISON OF SAFETY AND EFFICACY OF POST PARTUM INTRAUTERINE CONTRACEPTIVE DEVICE WITH INTERVAL INTRAUTERINE CONTRACEPTIVE DEVICE</title><source>Nexis UK</source><source>Publicly Available Content (ProQuest)</source><creator>Arif, Nadia ; Zafar, Bushra ; Raja Qaseem Ahmed ; Farrukh Shehzad</creator><creatorcontrib>Arif, Nadia ; Zafar, Bushra ; Raja Qaseem Ahmed ; Farrukh Shehzad</creatorcontrib><description>ABSTRACT Objective: To compare the safety and efficacy of post partum intrauterine contraceptive device with interval intrauterine contraceptive device, to avoid unplanned pregnancies. Study Design: Quasi-experimental study. Place and Duration of Study: Gynaecology and Obstetrics Department, Combined Military Hospital (CMH) Okara, from Aug 2019 to Jul 2020 Methodology: One hundred patients were included in the study. Divided in 2 groups, group A (post partum intrauterine contraceptive device, n=50) patients underwent cesarean section under spinal anesthesia, after removal of placenta and membranes contraceptive device was placed near fundus with fingers and incision was closed. In group B (interval intrauterine contraceptive device, n=50) and intrauterine contraceptive device was placed 6 weeks postpartum. Post insertion follow up was at 6 weeks and then 6 months. Efficacy was assessed by the continuation rate and safety, by presence or otherwise of heavy menstrual bleeding, lost threads, abnormal vaginal discharge and pain abdomen on follow up visits. Results: Efficacy in group A was 46 (92%) and in group B 40 (80%). Safety that is heavy menstrual bleeding 3 (6%) and 5 (10%), lost threads 3 (6%) and 1 (2%), abnormal vaginal discharge 2 (4%), and 3 (6%), and pain abdomen 1 (2%) and 2 (4%) in groups A and B respectively. Conclusion: Postpartum intrauterine contraceptive device insertion was found to be effective and safe method as compared to interval intrauterine contraceptive device. Successful placement, continuation and retention rate were significantly higher in post placental intra uterine contraceptive device insertion.</description><identifier>ISSN: 0030-9648</identifier><identifier>EISSN: 2411-8842</identifier><language>eng</language><publisher>Rawalpindi: Knowledge Bylanes</publisher><subject>Abdomen ; acceptability ; Age ; Birth control ; Birth rate ; Cesarean section ; Comparative analysis ; contraception ; Contraceptives ; Economic growth ; efficacy ; Family planning ; intrauterine contraceptive device ; Intrauterine devices ; IUD ; Maternal & child health ; Menstruation ; Pain ; Patients ; Population ; Vagina ; Womens health</subject><ispartof>Pakistan Armed Forces medical journal, 2020-10, Vol.70 (5), p.1419-1423</ispartof><rights>COPYRIGHT 2020 Knowledge Bylanes</rights><rights>(c)2020 Pakistan Armed Forces Medical Journal</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.proquest.com/docview/2473708064/fulltextPDF?pq-origsite=primo$$EPDF$$P50$$Gproquest$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://www.proquest.com/docview/2473708064?pq-origsite=primo$$EHTML$$P50$$Gproquest$$Hfree_for_read</linktohtml><link.rule.ids>314,776,780,25732,36991,44569,74872</link.rule.ids></links><search><creatorcontrib>Arif, Nadia</creatorcontrib><creatorcontrib>Zafar, Bushra</creatorcontrib><creatorcontrib>Raja Qaseem Ahmed</creatorcontrib><creatorcontrib>Farrukh Shehzad</creatorcontrib><title>A STUDY ON THE COMPARISON OF SAFETY AND EFFICACY OF POST PARTUM INTRAUTERINE CONTRACEPTIVE DEVICE WITH INTERVAL INTRAUTERINE CONTRACEPTIVE DEVICE</title><title>Pakistan Armed Forces medical journal</title><description>ABSTRACT Objective: To compare the safety and efficacy of post partum intrauterine contraceptive device with interval intrauterine contraceptive device, to avoid unplanned pregnancies. Study Design: Quasi-experimental study. Place and Duration of Study: Gynaecology and Obstetrics Department, Combined Military Hospital (CMH) Okara, from Aug 2019 to Jul 2020 Methodology: One hundred patients were included in the study. Divided in 2 groups, group A (post partum intrauterine contraceptive device, n=50) patients underwent cesarean section under spinal anesthesia, after removal of placenta and membranes contraceptive device was placed near fundus with fingers and incision was closed. In group B (interval intrauterine contraceptive device, n=50) and intrauterine contraceptive device was placed 6 weeks postpartum. Post insertion follow up was at 6 weeks and then 6 months. Efficacy was assessed by the continuation rate and safety, by presence or otherwise of heavy menstrual bleeding, lost threads, abnormal vaginal discharge and pain abdomen on follow up visits. Results: Efficacy in group A was 46 (92%) and in group B 40 (80%). Safety that is heavy menstrual bleeding 3 (6%) and 5 (10%), lost threads 3 (6%) and 1 (2%), abnormal vaginal discharge 2 (4%), and 3 (6%), and pain abdomen 1 (2%) and 2 (4%) in groups A and B respectively. Conclusion: Postpartum intrauterine contraceptive device insertion was found to be effective and safe method as compared to interval intrauterine contraceptive device. Successful placement, continuation and retention rate were significantly higher in post placental intra uterine contraceptive device insertion.</description><subject>Abdomen</subject><subject>acceptability</subject><subject>Age</subject><subject>Birth control</subject><subject>Birth rate</subject><subject>Cesarean section</subject><subject>Comparative analysis</subject><subject>contraception</subject><subject>Contraceptives</subject><subject>Economic growth</subject><subject>efficacy</subject><subject>Family planning</subject><subject>intrauterine contraceptive device</subject><subject>Intrauterine devices</subject><subject>IUD</subject><subject>Maternal & child health</subject><subject>Menstruation</subject><subject>Pain</subject><subject>Patients</subject><subject>Population</subject><subject>Vagina</subject><subject>Womens health</subject><issn>0030-9648</issn><issn>2411-8842</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2020</creationdate><recordtype>article</recordtype><sourceid>PIMPY</sourceid><sourceid>DOA</sourceid><recordid>eNqFj89Kw0AQxoMoWKrvsOA5Mtl_2RxDurWBNintttJT2Gw2kmKbmtSDj-Ebu1FBD4Izh2E-vvnxzYU3wjQIfCEovvRGAAT8iFNx7d32_R5cMYIpsJH3HqO12kx2KM-QmkmU5ItlvErXbs2naB1PpdqhOJsgOZ2mSZzsBnmZrxVyNrVZoDRTq3ij5CrNhuthS-RSpVuJJnKbJhI9pmo22ORqG8__9994V7V-7u3t9xx7Gxcimfnz_MElmPsVJsHZZ5rzgFdMlNSUJY7cS2UZAoMIE6orzY1lzBABpNJgo4gLKHnAeFjX3GjgZOylX9yq1fvi1DUH3b0VrW6KT6HtngrdnRvzbAvAQQmcVcKCpYboyLUNSyxMbTAn4Fh3X6xT17682v5c7NvX7ujiF5iGJAQBnP64nrSDNse6PXfaHJreFDGnQciBsYF1_4fLdWUPjWmPtm6c_uvgA-wkilk</recordid><startdate>20201031</startdate><enddate>20201031</enddate><creator>Arif, Nadia</creator><creator>Zafar, Bushra</creator><creator>Raja Qaseem Ahmed</creator><creator>Farrukh Shehzad</creator><general>Knowledge Bylanes</general><general>AsiaNet Pakistan (Pvt) Ltd</general><general>Army Medical College Rawalpindi</general><scope>3V.</scope><scope>7X7</scope><scope>7XB</scope><scope>8FI</scope><scope>8FJ</scope><scope>8FK</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>AZQEC</scope><scope>BENPR</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>FYUFA</scope><scope>GHDGH</scope><scope>K9.</scope><scope>M0S</scope><scope>PIMPY</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>DOA</scope></search><sort><creationdate>20201031</creationdate><title>A STUDY ON THE COMPARISON OF SAFETY AND EFFICACY OF POST PARTUM INTRAUTERINE CONTRACEPTIVE DEVICE WITH INTERVAL INTRAUTERINE CONTRACEPTIVE DEVICE</title><author>Arif, Nadia ; Zafar, Bushra ; Raja Qaseem Ahmed ; Farrukh Shehzad</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-d231t-5a6616d58b4cbb29005bb70509234ada6ce55c3803da0e99680b61567ff6ca063</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2020</creationdate><topic>Abdomen</topic><topic>acceptability</topic><topic>Age</topic><topic>Birth control</topic><topic>Birth rate</topic><topic>Cesarean section</topic><topic>Comparative analysis</topic><topic>contraception</topic><topic>Contraceptives</topic><topic>Economic growth</topic><topic>efficacy</topic><topic>Family planning</topic><topic>intrauterine contraceptive device</topic><topic>Intrauterine devices</topic><topic>IUD</topic><topic>Maternal & child health</topic><topic>Menstruation</topic><topic>Pain</topic><topic>Patients</topic><topic>Population</topic><topic>Vagina</topic><topic>Womens health</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Arif, Nadia</creatorcontrib><creatorcontrib>Zafar, Bushra</creatorcontrib><creatorcontrib>Raja Qaseem Ahmed</creatorcontrib><creatorcontrib>Farrukh Shehzad</creatorcontrib><collection>ProQuest Central (Corporate)</collection><collection>Health & Medical Collection</collection><collection>ProQuest Central (purchase pre-March 2016)</collection><collection>Hospital Premium Collection</collection><collection>Hospital Premium Collection (Alumni Edition)</collection><collection>ProQuest Central (Alumni) (purchase pre-March 2016)</collection><collection>ProQuest Central (Alumni)</collection><collection>ProQuest Central</collection><collection>ProQuest Central Essentials</collection><collection>ProQuest Central</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central</collection><collection>Health Research Premium Collection</collection><collection>Health Research Premium Collection (Alumni)</collection><collection>ProQuest Health & Medical Complete (Alumni)</collection><collection>Health & Medical Collection (Alumni Edition)</collection><collection>Publicly Available Content (ProQuest)</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>DOAJÂ Directory of Open Access Journals</collection><jtitle>Pakistan Armed Forces medical journal</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Arif, Nadia</au><au>Zafar, Bushra</au><au>Raja Qaseem Ahmed</au><au>Farrukh Shehzad</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A STUDY ON THE COMPARISON OF SAFETY AND EFFICACY OF POST PARTUM INTRAUTERINE CONTRACEPTIVE DEVICE WITH INTERVAL INTRAUTERINE CONTRACEPTIVE DEVICE</atitle><jtitle>Pakistan Armed Forces medical journal</jtitle><date>2020-10-31</date><risdate>2020</risdate><volume>70</volume><issue>5</issue><spage>1419</spage><epage>1423</epage><pages>1419-1423</pages><issn>0030-9648</issn><eissn>2411-8842</eissn><abstract>ABSTRACT Objective: To compare the safety and efficacy of post partum intrauterine contraceptive device with interval intrauterine contraceptive device, to avoid unplanned pregnancies. Study Design: Quasi-experimental study. Place and Duration of Study: Gynaecology and Obstetrics Department, Combined Military Hospital (CMH) Okara, from Aug 2019 to Jul 2020 Methodology: One hundred patients were included in the study. Divided in 2 groups, group A (post partum intrauterine contraceptive device, n=50) patients underwent cesarean section under spinal anesthesia, after removal of placenta and membranes contraceptive device was placed near fundus with fingers and incision was closed. In group B (interval intrauterine contraceptive device, n=50) and intrauterine contraceptive device was placed 6 weeks postpartum. Post insertion follow up was at 6 weeks and then 6 months. Efficacy was assessed by the continuation rate and safety, by presence or otherwise of heavy menstrual bleeding, lost threads, abnormal vaginal discharge and pain abdomen on follow up visits. Results: Efficacy in group A was 46 (92%) and in group B 40 (80%). Safety that is heavy menstrual bleeding 3 (6%) and 5 (10%), lost threads 3 (6%) and 1 (2%), abnormal vaginal discharge 2 (4%), and 3 (6%), and pain abdomen 1 (2%) and 2 (4%) in groups A and B respectively. Conclusion: Postpartum intrauterine contraceptive device insertion was found to be effective and safe method as compared to interval intrauterine contraceptive device. Successful placement, continuation and retention rate were significantly higher in post placental intra uterine contraceptive device insertion.</abstract><cop>Rawalpindi</cop><pub>Knowledge Bylanes</pub><tpages>5</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0030-9648 |
ispartof | Pakistan Armed Forces medical journal, 2020-10, Vol.70 (5), p.1419-1423 |
issn | 0030-9648 2411-8842 |
language | eng |
recordid | cdi_doaj_primary_oai_doaj_org_article_021b065d8e0e4c3a9a9ae7b28cfc2630 |
source | Nexis UK; Publicly Available Content (ProQuest) |
subjects | Abdomen acceptability Age Birth control Birth rate Cesarean section Comparative analysis contraception Contraceptives Economic growth efficacy Family planning intrauterine contraceptive device Intrauterine devices IUD Maternal & child health Menstruation Pain Patients Population Vagina Womens health |
title | A STUDY ON THE COMPARISON OF SAFETY AND EFFICACY OF POST PARTUM INTRAUTERINE CONTRACEPTIVE DEVICE WITH INTERVAL INTRAUTERINE CONTRACEPTIVE DEVICE |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-27T02%3A37%3A48IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-gale_doaj_&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20STUDY%20ON%20THE%20COMPARISON%20OF%20SAFETY%20AND%20EFFICACY%20OF%20POST%20PARTUM%20INTRAUTERINE%20CONTRACEPTIVE%20DEVICE%20WITH%20INTERVAL%20INTRAUTERINE%20CONTRACEPTIVE%20DEVICE&rft.jtitle=Pakistan%20Armed%20Forces%20medical%20journal&rft.au=Arif,%20Nadia&rft.date=2020-10-31&rft.volume=70&rft.issue=5&rft.spage=1419&rft.epage=1423&rft.pages=1419-1423&rft.issn=0030-9648&rft.eissn=2411-8842&rft_id=info:doi/&rft_dat=%3Cgale_doaj_%3EA641760550%3C/gale_doaj_%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-d231t-5a6616d58b4cbb29005bb70509234ada6ce55c3803da0e99680b61567ff6ca063%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2473708064&rft_id=info:pmid/&rft_galeid=A641760550&rfr_iscdi=true |