Loading…

A STUDY ON THE COMPARISON OF SAFETY AND EFFICACY OF POST PARTUM INTRAUTERINE CONTRACEPTIVE DEVICE WITH INTERVAL INTRAUTERINE CONTRACEPTIVE DEVICE

ABSTRACT Objective: To compare the safety and efficacy of post partum intrauterine contraceptive device with interval intrauterine contraceptive device, to avoid unplanned pregnancies. Study Design: Quasi-experimental study. Place and Duration of Study: Gynaecology and Obstetrics Department, Combine...

Full description

Saved in:
Bibliographic Details
Published in:Pakistan Armed Forces medical journal 2020-10, Vol.70 (5), p.1419-1423
Main Authors: Arif, Nadia, Zafar, Bushra, Raja Qaseem Ahmed, Farrukh Shehzad
Format: Article
Language:English
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by
cites
container_end_page 1423
container_issue 5
container_start_page 1419
container_title Pakistan Armed Forces medical journal
container_volume 70
creator Arif, Nadia
Zafar, Bushra
Raja Qaseem Ahmed
Farrukh Shehzad
description ABSTRACT Objective: To compare the safety and efficacy of post partum intrauterine contraceptive device with interval intrauterine contraceptive device, to avoid unplanned pregnancies. Study Design: Quasi-experimental study. Place and Duration of Study: Gynaecology and Obstetrics Department, Combined Military Hospital (CMH) Okara, from Aug 2019 to Jul 2020 Methodology: One hundred patients were included in the study. Divided in 2 groups, group A (post partum intrauterine contraceptive device, n=50) patients underwent cesarean section under spinal anesthesia, after removal of placenta and membranes contraceptive device was placed near fundus with fingers and incision was closed. In group B (interval intrauterine contraceptive device, n=50) and intrauterine contraceptive device was placed 6 weeks postpartum. Post insertion follow up was at 6 weeks and then 6 months. Efficacy was assessed by the continuation rate and safety, by presence or otherwise of heavy menstrual bleeding, lost threads, abnormal vaginal discharge and pain abdomen on follow up visits. Results: Efficacy in group A was 46 (92%) and in group B 40 (80%). Safety that is heavy menstrual bleeding 3 (6%) and 5 (10%), lost threads 3 (6%) and 1 (2%), abnormal vaginal discharge 2 (4%), and 3 (6%), and pain abdomen 1 (2%) and 2 (4%) in groups A and B respectively. Conclusion: Postpartum intrauterine contraceptive device insertion was found to be effective and safe method as compared to interval intrauterine contraceptive device. Successful placement, continuation and retention rate were significantly higher in post placental intra uterine contraceptive device insertion.
format article
fullrecord <record><control><sourceid>gale_doaj_</sourceid><recordid>TN_cdi_doaj_primary_oai_doaj_org_article_021b065d8e0e4c3a9a9ae7b28cfc2630</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><galeid>A641760550</galeid><doaj_id>oai_doaj_org_article_021b065d8e0e4c3a9a9ae7b28cfc2630</doaj_id><sourcerecordid>A641760550</sourcerecordid><originalsourceid>FETCH-LOGICAL-d231t-5a6616d58b4cbb29005bb70509234ada6ce55c3803da0e99680b61567ff6ca063</originalsourceid><addsrcrecordid>eNqFj89Kw0AQxoMoWKrvsOA5Mtl_2RxDurWBNintttJT2Gw2kmKbmtSDj-Ebu1FBD4Izh2E-vvnxzYU3wjQIfCEovvRGAAT8iFNx7d32_R5cMYIpsJH3HqO12kx2KM-QmkmU5ItlvErXbs2naB1PpdqhOJsgOZ2mSZzsBnmZrxVyNrVZoDRTq3ij5CrNhuthS-RSpVuJJnKbJhI9pmo22ORqG8__9994V7V-7u3t9xx7Gxcimfnz_MElmPsVJsHZZ5rzgFdMlNSUJY7cS2UZAoMIE6orzY1lzBABpNJgo4gLKHnAeFjX3GjgZOylX9yq1fvi1DUH3b0VrW6KT6HtngrdnRvzbAvAQQmcVcKCpYboyLUNSyxMbTAn4Fh3X6xT17682v5c7NvX7ujiF5iGJAQBnP64nrSDNse6PXfaHJreFDGnQciBsYF1_4fLdWUPjWmPtm6c_uvgA-wkilk</addsrcrecordid><sourcetype>Open Website</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2473708064</pqid></control><display><type>article</type><title>A STUDY ON THE COMPARISON OF SAFETY AND EFFICACY OF POST PARTUM INTRAUTERINE CONTRACEPTIVE DEVICE WITH INTERVAL INTRAUTERINE CONTRACEPTIVE DEVICE</title><source>Nexis UK</source><source>Publicly Available Content (ProQuest)</source><creator>Arif, Nadia ; Zafar, Bushra ; Raja Qaseem Ahmed ; Farrukh Shehzad</creator><creatorcontrib>Arif, Nadia ; Zafar, Bushra ; Raja Qaseem Ahmed ; Farrukh Shehzad</creatorcontrib><description>ABSTRACT Objective: To compare the safety and efficacy of post partum intrauterine contraceptive device with interval intrauterine contraceptive device, to avoid unplanned pregnancies. Study Design: Quasi-experimental study. Place and Duration of Study: Gynaecology and Obstetrics Department, Combined Military Hospital (CMH) Okara, from Aug 2019 to Jul 2020 Methodology: One hundred patients were included in the study. Divided in 2 groups, group A (post partum intrauterine contraceptive device, n=50) patients underwent cesarean section under spinal anesthesia, after removal of placenta and membranes contraceptive device was placed near fundus with fingers and incision was closed. In group B (interval intrauterine contraceptive device, n=50) and intrauterine contraceptive device was placed 6 weeks postpartum. Post insertion follow up was at 6 weeks and then 6 months. Efficacy was assessed by the continuation rate and safety, by presence or otherwise of heavy menstrual bleeding, lost threads, abnormal vaginal discharge and pain abdomen on follow up visits. Results: Efficacy in group A was 46 (92%) and in group B 40 (80%). Safety that is heavy menstrual bleeding 3 (6%) and 5 (10%), lost threads 3 (6%) and 1 (2%), abnormal vaginal discharge 2 (4%), and 3 (6%), and pain abdomen 1 (2%) and 2 (4%) in groups A and B respectively. Conclusion: Postpartum intrauterine contraceptive device insertion was found to be effective and safe method as compared to interval intrauterine contraceptive device. Successful placement, continuation and retention rate were significantly higher in post placental intra uterine contraceptive device insertion.</description><identifier>ISSN: 0030-9648</identifier><identifier>EISSN: 2411-8842</identifier><language>eng</language><publisher>Rawalpindi: Knowledge Bylanes</publisher><subject>Abdomen ; acceptability ; Age ; Birth control ; Birth rate ; Cesarean section ; Comparative analysis ; contraception ; Contraceptives ; Economic growth ; efficacy ; Family planning ; intrauterine contraceptive device ; Intrauterine devices ; IUD ; Maternal &amp; child health ; Menstruation ; Pain ; Patients ; Population ; Vagina ; Womens health</subject><ispartof>Pakistan Armed Forces medical journal, 2020-10, Vol.70 (5), p.1419-1423</ispartof><rights>COPYRIGHT 2020 Knowledge Bylanes</rights><rights>(c)2020 Pakistan Armed Forces Medical Journal</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.proquest.com/docview/2473708064/fulltextPDF?pq-origsite=primo$$EPDF$$P50$$Gproquest$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://www.proquest.com/docview/2473708064?pq-origsite=primo$$EHTML$$P50$$Gproquest$$Hfree_for_read</linktohtml><link.rule.ids>314,776,780,25732,36991,44569,74872</link.rule.ids></links><search><creatorcontrib>Arif, Nadia</creatorcontrib><creatorcontrib>Zafar, Bushra</creatorcontrib><creatorcontrib>Raja Qaseem Ahmed</creatorcontrib><creatorcontrib>Farrukh Shehzad</creatorcontrib><title>A STUDY ON THE COMPARISON OF SAFETY AND EFFICACY OF POST PARTUM INTRAUTERINE CONTRACEPTIVE DEVICE WITH INTERVAL INTRAUTERINE CONTRACEPTIVE DEVICE</title><title>Pakistan Armed Forces medical journal</title><description>ABSTRACT Objective: To compare the safety and efficacy of post partum intrauterine contraceptive device with interval intrauterine contraceptive device, to avoid unplanned pregnancies. Study Design: Quasi-experimental study. Place and Duration of Study: Gynaecology and Obstetrics Department, Combined Military Hospital (CMH) Okara, from Aug 2019 to Jul 2020 Methodology: One hundred patients were included in the study. Divided in 2 groups, group A (post partum intrauterine contraceptive device, n=50) patients underwent cesarean section under spinal anesthesia, after removal of placenta and membranes contraceptive device was placed near fundus with fingers and incision was closed. In group B (interval intrauterine contraceptive device, n=50) and intrauterine contraceptive device was placed 6 weeks postpartum. Post insertion follow up was at 6 weeks and then 6 months. Efficacy was assessed by the continuation rate and safety, by presence or otherwise of heavy menstrual bleeding, lost threads, abnormal vaginal discharge and pain abdomen on follow up visits. Results: Efficacy in group A was 46 (92%) and in group B 40 (80%). Safety that is heavy menstrual bleeding 3 (6%) and 5 (10%), lost threads 3 (6%) and 1 (2%), abnormal vaginal discharge 2 (4%), and 3 (6%), and pain abdomen 1 (2%) and 2 (4%) in groups A and B respectively. Conclusion: Postpartum intrauterine contraceptive device insertion was found to be effective and safe method as compared to interval intrauterine contraceptive device. Successful placement, continuation and retention rate were significantly higher in post placental intra uterine contraceptive device insertion.</description><subject>Abdomen</subject><subject>acceptability</subject><subject>Age</subject><subject>Birth control</subject><subject>Birth rate</subject><subject>Cesarean section</subject><subject>Comparative analysis</subject><subject>contraception</subject><subject>Contraceptives</subject><subject>Economic growth</subject><subject>efficacy</subject><subject>Family planning</subject><subject>intrauterine contraceptive device</subject><subject>Intrauterine devices</subject><subject>IUD</subject><subject>Maternal &amp; child health</subject><subject>Menstruation</subject><subject>Pain</subject><subject>Patients</subject><subject>Population</subject><subject>Vagina</subject><subject>Womens health</subject><issn>0030-9648</issn><issn>2411-8842</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2020</creationdate><recordtype>article</recordtype><sourceid>PIMPY</sourceid><sourceid>DOA</sourceid><recordid>eNqFj89Kw0AQxoMoWKrvsOA5Mtl_2RxDurWBNintttJT2Gw2kmKbmtSDj-Ebu1FBD4Izh2E-vvnxzYU3wjQIfCEovvRGAAT8iFNx7d32_R5cMYIpsJH3HqO12kx2KM-QmkmU5ItlvErXbs2naB1PpdqhOJsgOZ2mSZzsBnmZrxVyNrVZoDRTq3ij5CrNhuthS-RSpVuJJnKbJhI9pmo22ORqG8__9994V7V-7u3t9xx7Gxcimfnz_MElmPsVJsHZZ5rzgFdMlNSUJY7cS2UZAoMIE6orzY1lzBABpNJgo4gLKHnAeFjX3GjgZOylX9yq1fvi1DUH3b0VrW6KT6HtngrdnRvzbAvAQQmcVcKCpYboyLUNSyxMbTAn4Fh3X6xT17682v5c7NvX7ujiF5iGJAQBnP64nrSDNse6PXfaHJreFDGnQciBsYF1_4fLdWUPjWmPtm6c_uvgA-wkilk</recordid><startdate>20201031</startdate><enddate>20201031</enddate><creator>Arif, Nadia</creator><creator>Zafar, Bushra</creator><creator>Raja Qaseem Ahmed</creator><creator>Farrukh Shehzad</creator><general>Knowledge Bylanes</general><general>AsiaNet Pakistan (Pvt) Ltd</general><general>Army Medical College Rawalpindi</general><scope>3V.</scope><scope>7X7</scope><scope>7XB</scope><scope>8FI</scope><scope>8FJ</scope><scope>8FK</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>AZQEC</scope><scope>BENPR</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>FYUFA</scope><scope>GHDGH</scope><scope>K9.</scope><scope>M0S</scope><scope>PIMPY</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>DOA</scope></search><sort><creationdate>20201031</creationdate><title>A STUDY ON THE COMPARISON OF SAFETY AND EFFICACY OF POST PARTUM INTRAUTERINE CONTRACEPTIVE DEVICE WITH INTERVAL INTRAUTERINE CONTRACEPTIVE DEVICE</title><author>Arif, Nadia ; Zafar, Bushra ; Raja Qaseem Ahmed ; Farrukh Shehzad</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-d231t-5a6616d58b4cbb29005bb70509234ada6ce55c3803da0e99680b61567ff6ca063</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2020</creationdate><topic>Abdomen</topic><topic>acceptability</topic><topic>Age</topic><topic>Birth control</topic><topic>Birth rate</topic><topic>Cesarean section</topic><topic>Comparative analysis</topic><topic>contraception</topic><topic>Contraceptives</topic><topic>Economic growth</topic><topic>efficacy</topic><topic>Family planning</topic><topic>intrauterine contraceptive device</topic><topic>Intrauterine devices</topic><topic>IUD</topic><topic>Maternal &amp; child health</topic><topic>Menstruation</topic><topic>Pain</topic><topic>Patients</topic><topic>Population</topic><topic>Vagina</topic><topic>Womens health</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Arif, Nadia</creatorcontrib><creatorcontrib>Zafar, Bushra</creatorcontrib><creatorcontrib>Raja Qaseem Ahmed</creatorcontrib><creatorcontrib>Farrukh Shehzad</creatorcontrib><collection>ProQuest Central (Corporate)</collection><collection>Health &amp; Medical Collection</collection><collection>ProQuest Central (purchase pre-March 2016)</collection><collection>Hospital Premium Collection</collection><collection>Hospital Premium Collection (Alumni Edition)</collection><collection>ProQuest Central (Alumni) (purchase pre-March 2016)</collection><collection>ProQuest Central (Alumni)</collection><collection>ProQuest Central</collection><collection>ProQuest Central Essentials</collection><collection>ProQuest Central</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central</collection><collection>Health Research Premium Collection</collection><collection>Health Research Premium Collection (Alumni)</collection><collection>ProQuest Health &amp; Medical Complete (Alumni)</collection><collection>Health &amp; Medical Collection (Alumni Edition)</collection><collection>Publicly Available Content (ProQuest)</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>DOAJ Directory of Open Access Journals</collection><jtitle>Pakistan Armed Forces medical journal</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Arif, Nadia</au><au>Zafar, Bushra</au><au>Raja Qaseem Ahmed</au><au>Farrukh Shehzad</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A STUDY ON THE COMPARISON OF SAFETY AND EFFICACY OF POST PARTUM INTRAUTERINE CONTRACEPTIVE DEVICE WITH INTERVAL INTRAUTERINE CONTRACEPTIVE DEVICE</atitle><jtitle>Pakistan Armed Forces medical journal</jtitle><date>2020-10-31</date><risdate>2020</risdate><volume>70</volume><issue>5</issue><spage>1419</spage><epage>1423</epage><pages>1419-1423</pages><issn>0030-9648</issn><eissn>2411-8842</eissn><abstract>ABSTRACT Objective: To compare the safety and efficacy of post partum intrauterine contraceptive device with interval intrauterine contraceptive device, to avoid unplanned pregnancies. Study Design: Quasi-experimental study. Place and Duration of Study: Gynaecology and Obstetrics Department, Combined Military Hospital (CMH) Okara, from Aug 2019 to Jul 2020 Methodology: One hundred patients were included in the study. Divided in 2 groups, group A (post partum intrauterine contraceptive device, n=50) patients underwent cesarean section under spinal anesthesia, after removal of placenta and membranes contraceptive device was placed near fundus with fingers and incision was closed. In group B (interval intrauterine contraceptive device, n=50) and intrauterine contraceptive device was placed 6 weeks postpartum. Post insertion follow up was at 6 weeks and then 6 months. Efficacy was assessed by the continuation rate and safety, by presence or otherwise of heavy menstrual bleeding, lost threads, abnormal vaginal discharge and pain abdomen on follow up visits. Results: Efficacy in group A was 46 (92%) and in group B 40 (80%). Safety that is heavy menstrual bleeding 3 (6%) and 5 (10%), lost threads 3 (6%) and 1 (2%), abnormal vaginal discharge 2 (4%), and 3 (6%), and pain abdomen 1 (2%) and 2 (4%) in groups A and B respectively. Conclusion: Postpartum intrauterine contraceptive device insertion was found to be effective and safe method as compared to interval intrauterine contraceptive device. Successful placement, continuation and retention rate were significantly higher in post placental intra uterine contraceptive device insertion.</abstract><cop>Rawalpindi</cop><pub>Knowledge Bylanes</pub><tpages>5</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0030-9648
ispartof Pakistan Armed Forces medical journal, 2020-10, Vol.70 (5), p.1419-1423
issn 0030-9648
2411-8842
language eng
recordid cdi_doaj_primary_oai_doaj_org_article_021b065d8e0e4c3a9a9ae7b28cfc2630
source Nexis UK; Publicly Available Content (ProQuest)
subjects Abdomen
acceptability
Age
Birth control
Birth rate
Cesarean section
Comparative analysis
contraception
Contraceptives
Economic growth
efficacy
Family planning
intrauterine contraceptive device
Intrauterine devices
IUD
Maternal & child health
Menstruation
Pain
Patients
Population
Vagina
Womens health
title A STUDY ON THE COMPARISON OF SAFETY AND EFFICACY OF POST PARTUM INTRAUTERINE CONTRACEPTIVE DEVICE WITH INTERVAL INTRAUTERINE CONTRACEPTIVE DEVICE
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-27T02%3A37%3A48IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-gale_doaj_&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20STUDY%20ON%20THE%20COMPARISON%20OF%20SAFETY%20AND%20EFFICACY%20OF%20POST%20PARTUM%20INTRAUTERINE%20CONTRACEPTIVE%20DEVICE%20WITH%20INTERVAL%20INTRAUTERINE%20CONTRACEPTIVE%20DEVICE&rft.jtitle=Pakistan%20Armed%20Forces%20medical%20journal&rft.au=Arif,%20Nadia&rft.date=2020-10-31&rft.volume=70&rft.issue=5&rft.spage=1419&rft.epage=1423&rft.pages=1419-1423&rft.issn=0030-9648&rft.eissn=2411-8842&rft_id=info:doi/&rft_dat=%3Cgale_doaj_%3EA641760550%3C/gale_doaj_%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-d231t-5a6616d58b4cbb29005bb70509234ada6ce55c3803da0e99680b61567ff6ca063%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2473708064&rft_id=info:pmid/&rft_galeid=A641760550&rfr_iscdi=true