Loading…

Accelerometer-assessed physical behavior and the association with clinical outcomes in implantable cardioverter-defibrillator recipients: A systematic review

Current implantable cardioverter-defibrillator (ICD) devices are equipped with a device-embedded accelerometer capable of capturing physical activity (PA). In contrast, wearable accelerometer-based methods enable the measurement of physical behavior (PB) that encompasses not only PA but also sleep b...

Full description

Saved in:
Bibliographic Details
Published in:Cardiovascular digital health journal 2022-02, Vol.3 (1), p.46-55
Main Authors: Kolk, Maarten Z.H., Frodi, Diana M., Andersen, Tariq O., Langford, Joss, Diederichsen, Soeren Z., Svendsen, Jesper H., Tan, Hanno L., Knops, Reinoud E., Tjong, Fleur V.Y.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Current implantable cardioverter-defibrillator (ICD) devices are equipped with a device-embedded accelerometer capable of capturing physical activity (PA). In contrast, wearable accelerometer-based methods enable the measurement of physical behavior (PB) that encompasses not only PA but also sleep behavior, sedentary time, and rest-activity patterns. This systematic review evaluates accelerometer-based methods used in patients carrying an ICD or at high risk of sudden cardiac death. Papers were identified via the OVID MEDLINE and OVID EMBASE databases. PB could be assessed using a wearable accelerometer or an embedded accelerometer in the ICD. A total of 52 papers were deemed appropriate for this review. Out of these studies, 30 examined device-embedded accelerometry (189,811 patients), 19 examined wearable accelerometry (1601 patients), and 3 validated wearable accelerometry against device-embedded accelerometry (106 patients). The main findings were that a low level of PA after implantation of the ICD and a decline in PA were both associated with an increased risk of mortality, heart failure hospitalization, and appropriate ICD shock. Second, PA was affected by cardiac factors (eg, onset of atrial fibrillation, ICD shocks) and noncardiac factors (eg, seasonal differences, societal factors). This review demonstrated the potential of accelerometer-measured PA as a marker of clinical deterioration and ventricular arrhythmias. Notwithstanding that the evidence of PB assessed using wearable accelerometry was limited, there seems to be potential for accelerometers to improve early warning systems and facilitate preventative and proactive strategies.
ISSN:2666-6936
2666-6936
DOI:10.1016/j.cvdhj.2021.11.006