Sequential transcatheter aortic valve implantation due to valve dislodgement - a Portico valve implanted over a CoreValve bioprosthesis

Transcatheter aortic valve implantation (TAVI) has become an important treatment in high surgical risk patients with severe aortic stenosis (AS), whose complications need to be managed promptly. The authors report the case of an 86-year-old woman presenting with severe symptomatic AS, rejected for s...

Full description

Saved in:
Bibliographic Details
Published in:Revista portuguesa de cardiologia 2017-03, Vol.36 (3), p.215.e1-215.e4
Main Authors: Campante Teles, Rui, Costa, Cátia, Almeida, Manuel, Brito, João, Sondergaard, Lars, Neves, José P., Abecasis, João, M. Gabriel, Henrique
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c422t-84c36a31853eb2ca68d0a49eb55880b901851e1fffbb452435315356dabe0e1e3
cites cdi_FETCH-LOGICAL-c422t-84c36a31853eb2ca68d0a49eb55880b901851e1fffbb452435315356dabe0e1e3
container_end_page 215.e4
container_issue 3
container_start_page 215.e1
container_title Revista portuguesa de cardiologia
container_volume 36
creator Campante Teles, Rui
Costa, Cátia
Almeida, Manuel
Brito, João
Sondergaard, Lars
Neves, José P.
Abecasis, João
M. Gabriel, Henrique
description Transcatheter aortic valve implantation (TAVI) has become an important treatment in high surgical risk patients with severe aortic stenosis (AS), whose complications need to be managed promptly. The authors report the case of an 86-year-old woman presenting with severe symptomatic AS, rejected for surgery due to advanced age and comorbidities. The patient underwent a first TAVI, with implantation of a Medtronic CoreValve®, which became dislodged and migrated to the ascending aorta. Due to the previous balloon valvuloplasty, the patient's AS became moderate, and her symptoms improved. After several months, she required another intervention, performed with a St. Jude Portico® repositionable self-expanding transcatheter aortic valve. There was a good clinical response that was maintained at one-year follow-up. The use of a self-expanding transcatheter bioprosthesis with repositioning features is a solution in cases of valve dislocation to avoid suboptimal positioning of a second implant, especially when the two valves have to be positioned overlapping or partially overlapping each other. A implantação de válvula aórtica percutânea (VAP) tornou-se um procedimento importante no tratamento de doentes com estenose aórtica grave com elevado risco cirúrgico, cujas complicações devem ser avaliadas e tratadas de forma adequada. Os autores relatam o caso de uma doente de 86 anos, com estenose aórtica grave sintomática, recusada para intervenção cirúrgica dada a idade avançada e comorbilidades. A doente foi submetida a uma primeira implantação de VAP com uma válvula Medtronic CoreValve®, a qual sofreu um deslocamento para a aorta ascendente durante o procedimento. Devido à angioplastia de balão previamente efetuada, a estenose aórtica tornou-se moderada, com melhoria da sintomatologia da doente. Vários meses depois, por agravamento clínico, houve necessidade de reintervenção, a qual foi realizada com um sistema reposicionável Portico®. Verificou-se um segundo posicionamento valvular adequado, com boa resposta clínica da doente, que persiste após um ano de follow-up. A utilização de sistemas reposicionáveis de implantação de VAP constitui, atualmente, uma solução em casos de deslocamento da válvula, de forma a evitar uma segunda implantação subótima, sobretudo quando as duas válvulas têm de ficar em sobreposição.
doi_str_mv 10.1016/j.repc.2016.03.012
format article
fullrecord <record><control><sourceid>proquest_doaj_</sourceid><recordid>TN_cdi_doaj_primary_oai_doaj_org_article_02ae1ca2ad684947bcd6468fa266649a</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0870255117300689</els_id><doaj_id>oai_doaj_org_article_02ae1ca2ad684947bcd6468fa266649a</doaj_id><sourcerecordid>1874782207</sourcerecordid><originalsourceid>FETCH-LOGICAL-c422t-84c36a31853eb2ca68d0a49eb55880b901851e1fffbb452435315356dabe0e1e3</originalsourceid><addsrcrecordid>eNp9UcuO1DAQjBCIHS37AxyQj1wS_IrjSFzQiIWVVgKJx9Xq2J3FoyQebM9IfAG_jTMzrMQFX2x1V1W7uqrqJaMNo0y92TUR97bh5d1Q0VDGn1QbzjpZcyro02pDdUdr3rbsqrpJaUfLUZT1Qj2vrrjmbS86uql-f8GfB1yyh4nkCEuykH9gxkggxOwtOcJ0ROLn_QRLhuzDQtwBSQ6XjvNpCu4B5yJCagLk84kX_iWiI-G4ipJtiPj91Bp82MeQyrjk04vq2QhTwpvLfV19u33_dfuxvv_04W777r62kvNca2mFAsF0K3DgFpR2FGSPQ9tqTYeelg5DNo7jMMiWS9EK1opWORiQIkNxXd2ddV2AndlHP0P8ZQJ4cyqE-GBg_f-EhnJAZoGDU1r2shusU1LpEbhSSvZQtF6ftYqNssSUzeyTxakYxnBIhulOdppz2hUoP0NtcZwijo-jGTVrnmZn1jzNmqehwpQ8C-nVRf8wzOgeKX_TK4C3ZwCWjR09RpOsx8Wi8xFtLpb8__T_AJJIswk</addsrcrecordid><sourcetype>Open Website</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1874782207</pqid></control><display><type>article</type><title>Sequential transcatheter aortic valve implantation due to valve dislodgement - a Portico valve implanted over a CoreValve bioprosthesis</title><source>ScienceDirect Journals</source><creator>Campante Teles, Rui ; Costa, Cátia ; Almeida, Manuel ; Brito, João ; Sondergaard, Lars ; Neves, José P. ; Abecasis, João ; M. Gabriel, Henrique</creator><creatorcontrib>Campante Teles, Rui ; Costa, Cátia ; Almeida, Manuel ; Brito, João ; Sondergaard, Lars ; Neves, José P. ; Abecasis, João ; M. Gabriel, Henrique</creatorcontrib><description>Transcatheter aortic valve implantation (TAVI) has become an important treatment in high surgical risk patients with severe aortic stenosis (AS), whose complications need to be managed promptly. The authors report the case of an 86-year-old woman presenting with severe symptomatic AS, rejected for surgery due to advanced age and comorbidities. The patient underwent a first TAVI, with implantation of a Medtronic CoreValve®, which became dislodged and migrated to the ascending aorta. Due to the previous balloon valvuloplasty, the patient's AS became moderate, and her symptoms improved. After several months, she required another intervention, performed with a St. Jude Portico® repositionable self-expanding transcatheter aortic valve. There was a good clinical response that was maintained at one-year follow-up. The use of a self-expanding transcatheter bioprosthesis with repositioning features is a solution in cases of valve dislocation to avoid suboptimal positioning of a second implant, especially when the two valves have to be positioned overlapping or partially overlapping each other. A implantação de válvula aórtica percutânea (VAP) tornou-se um procedimento importante no tratamento de doentes com estenose aórtica grave com elevado risco cirúrgico, cujas complicações devem ser avaliadas e tratadas de forma adequada. Os autores relatam o caso de uma doente de 86 anos, com estenose aórtica grave sintomática, recusada para intervenção cirúrgica dada a idade avançada e comorbilidades. A doente foi submetida a uma primeira implantação de VAP com uma válvula Medtronic CoreValve®, a qual sofreu um deslocamento para a aorta ascendente durante o procedimento. Devido à angioplastia de balão previamente efetuada, a estenose aórtica tornou-se moderada, com melhoria da sintomatologia da doente. Vários meses depois, por agravamento clínico, houve necessidade de reintervenção, a qual foi realizada com um sistema reposicionável Portico®. Verificou-se um segundo posicionamento valvular adequado, com boa resposta clínica da doente, que persiste após um ano de follow-up. A utilização de sistemas reposicionáveis de implantação de VAP constitui, atualmente, uma solução em casos de deslocamento da válvula, de forma a evitar uma segunda implantação subótima, sobretudo quando as duas válvulas têm de ficar em sobreposição.</description><identifier>ISSN: 0870-2551</identifier><identifier>EISSN: 2174-2030</identifier><identifier>DOI: 10.1016/j.repc.2016.03.012</identifier><identifier>PMID: 28259370</identifier><language>eng</language><publisher>Portugal: Elsevier España, S.L.U</publisher><subject>Aged, 80 and over ; Aortic Valve Stenosis - surgery ; Bioprosthesis ; Complicações da válvula aórtica percutânea ; Deslocamento da válvula ; Estenose aórtica grave ; Female ; Heart Valve Prosthesis ; Humans ; Postoperative Complications - surgery ; Prosthesis Design ; Prosthesis Failure ; Severe aortic stenosis ; Transcatheter aortic valve implantation complications ; Transcatheter Aortic Valve Replacement - methods ; Valve dislocation</subject><ispartof>Revista portuguesa de cardiologia, 2017-03, Vol.36 (3), p.215.e1-215.e4</ispartof><rights>2017 Sociedade Portuguesa de Cardiologia</rights><rights>Copyright © 2017 Sociedade Portuguesa de Cardiologia. Publicado por Elsevier España, S.L.U. All rights reserved.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c422t-84c36a31853eb2ca68d0a49eb55880b901851e1fffbb452435315356dabe0e1e3</citedby><cites>FETCH-LOGICAL-c422t-84c36a31853eb2ca68d0a49eb55880b901851e1fffbb452435315356dabe0e1e3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/S0870255117300689$$EHTML$$P50$$Gelsevier$$Hfree_for_read</linktohtml><link.rule.ids>314,777,781,3536,27905,27906,45761</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/28259370$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Campante Teles, Rui</creatorcontrib><creatorcontrib>Costa, Cátia</creatorcontrib><creatorcontrib>Almeida, Manuel</creatorcontrib><creatorcontrib>Brito, João</creatorcontrib><creatorcontrib>Sondergaard, Lars</creatorcontrib><creatorcontrib>Neves, José P.</creatorcontrib><creatorcontrib>Abecasis, João</creatorcontrib><creatorcontrib>M. Gabriel, Henrique</creatorcontrib><title>Sequential transcatheter aortic valve implantation due to valve dislodgement - a Portico valve implanted over a CoreValve bioprosthesis</title><title>Revista portuguesa de cardiologia</title><addtitle>Rev Port Cardiol</addtitle><description>Transcatheter aortic valve implantation (TAVI) has become an important treatment in high surgical risk patients with severe aortic stenosis (AS), whose complications need to be managed promptly. The authors report the case of an 86-year-old woman presenting with severe symptomatic AS, rejected for surgery due to advanced age and comorbidities. The patient underwent a first TAVI, with implantation of a Medtronic CoreValve®, which became dislodged and migrated to the ascending aorta. Due to the previous balloon valvuloplasty, the patient's AS became moderate, and her symptoms improved. After several months, she required another intervention, performed with a St. Jude Portico® repositionable self-expanding transcatheter aortic valve. There was a good clinical response that was maintained at one-year follow-up. The use of a self-expanding transcatheter bioprosthesis with repositioning features is a solution in cases of valve dislocation to avoid suboptimal positioning of a second implant, especially when the two valves have to be positioned overlapping or partially overlapping each other. A implantação de válvula aórtica percutânea (VAP) tornou-se um procedimento importante no tratamento de doentes com estenose aórtica grave com elevado risco cirúrgico, cujas complicações devem ser avaliadas e tratadas de forma adequada. Os autores relatam o caso de uma doente de 86 anos, com estenose aórtica grave sintomática, recusada para intervenção cirúrgica dada a idade avançada e comorbilidades. A doente foi submetida a uma primeira implantação de VAP com uma válvula Medtronic CoreValve®, a qual sofreu um deslocamento para a aorta ascendente durante o procedimento. Devido à angioplastia de balão previamente efetuada, a estenose aórtica tornou-se moderada, com melhoria da sintomatologia da doente. Vários meses depois, por agravamento clínico, houve necessidade de reintervenção, a qual foi realizada com um sistema reposicionável Portico®. Verificou-se um segundo posicionamento valvular adequado, com boa resposta clínica da doente, que persiste após um ano de follow-up. A utilização de sistemas reposicionáveis de implantação de VAP constitui, atualmente, uma solução em casos de deslocamento da válvula, de forma a evitar uma segunda implantação subótima, sobretudo quando as duas válvulas têm de ficar em sobreposição.</description><subject>Aged, 80 and over</subject><subject>Aortic Valve Stenosis - surgery</subject><subject>Bioprosthesis</subject><subject>Complicações da válvula aórtica percutânea</subject><subject>Deslocamento da válvula</subject><subject>Estenose aórtica grave</subject><subject>Female</subject><subject>Heart Valve Prosthesis</subject><subject>Humans</subject><subject>Postoperative Complications - surgery</subject><subject>Prosthesis Design</subject><subject>Prosthesis Failure</subject><subject>Severe aortic stenosis</subject><subject>Transcatheter aortic valve implantation complications</subject><subject>Transcatheter Aortic Valve Replacement - methods</subject><subject>Valve dislocation</subject><issn>0870-2551</issn><issn>2174-2030</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2017</creationdate><recordtype>article</recordtype><sourceid>DOA</sourceid><recordid>eNp9UcuO1DAQjBCIHS37AxyQj1wS_IrjSFzQiIWVVgKJx9Xq2J3FoyQebM9IfAG_jTMzrMQFX2x1V1W7uqrqJaMNo0y92TUR97bh5d1Q0VDGn1QbzjpZcyro02pDdUdr3rbsqrpJaUfLUZT1Qj2vrrjmbS86uql-f8GfB1yyh4nkCEuykH9gxkggxOwtOcJ0ROLn_QRLhuzDQtwBSQ6XjvNpCu4B5yJCagLk84kX_iWiI-G4ipJtiPj91Bp82MeQyrjk04vq2QhTwpvLfV19u33_dfuxvv_04W777r62kvNca2mFAsF0K3DgFpR2FGSPQ9tqTYeelg5DNo7jMMiWS9EK1opWORiQIkNxXd2ddV2AndlHP0P8ZQJ4cyqE-GBg_f-EhnJAZoGDU1r2shusU1LpEbhSSvZQtF6ftYqNssSUzeyTxakYxnBIhulOdppz2hUoP0NtcZwijo-jGTVrnmZn1jzNmqehwpQ8C-nVRf8wzOgeKX_TK4C3ZwCWjR09RpOsx8Wi8xFtLpb8__T_AJJIswk</recordid><startdate>201703</startdate><enddate>201703</enddate><creator>Campante Teles, Rui</creator><creator>Costa, Cátia</creator><creator>Almeida, Manuel</creator><creator>Brito, João</creator><creator>Sondergaard, Lars</creator><creator>Neves, José P.</creator><creator>Abecasis, João</creator><creator>M. Gabriel, Henrique</creator><general>Elsevier España, S.L.U</general><general>Elsevier</general><scope>6I.</scope><scope>AAFTH</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>DOA</scope></search><sort><creationdate>201703</creationdate><title>Sequential transcatheter aortic valve implantation due to valve dislodgement - a Portico valve implanted over a CoreValve bioprosthesis</title><author>Campante Teles, Rui ; Costa, Cátia ; Almeida, Manuel ; Brito, João ; Sondergaard, Lars ; Neves, José P. ; Abecasis, João ; M. Gabriel, Henrique</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c422t-84c36a31853eb2ca68d0a49eb55880b901851e1fffbb452435315356dabe0e1e3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2017</creationdate><topic>Aged, 80 and over</topic><topic>Aortic Valve Stenosis - surgery</topic><topic>Bioprosthesis</topic><topic>Complicações da válvula aórtica percutânea</topic><topic>Deslocamento da válvula</topic><topic>Estenose aórtica grave</topic><topic>Female</topic><topic>Heart Valve Prosthesis</topic><topic>Humans</topic><topic>Postoperative Complications - surgery</topic><topic>Prosthesis Design</topic><topic>Prosthesis Failure</topic><topic>Severe aortic stenosis</topic><topic>Transcatheter aortic valve implantation complications</topic><topic>Transcatheter Aortic Valve Replacement - methods</topic><topic>Valve dislocation</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Campante Teles, Rui</creatorcontrib><creatorcontrib>Costa, Cátia</creatorcontrib><creatorcontrib>Almeida, Manuel</creatorcontrib><creatorcontrib>Brito, João</creatorcontrib><creatorcontrib>Sondergaard, Lars</creatorcontrib><creatorcontrib>Neves, José P.</creatorcontrib><creatorcontrib>Abecasis, João</creatorcontrib><creatorcontrib>M. Gabriel, Henrique</creatorcontrib><collection>ScienceDirect Open Access Titles</collection><collection>Elsevier:ScienceDirect:Open Access</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>DOAJ (Directory of Open Access Journals)</collection><jtitle>Revista portuguesa de cardiologia</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Campante Teles, Rui</au><au>Costa, Cátia</au><au>Almeida, Manuel</au><au>Brito, João</au><au>Sondergaard, Lars</au><au>Neves, José P.</au><au>Abecasis, João</au><au>M. Gabriel, Henrique</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Sequential transcatheter aortic valve implantation due to valve dislodgement - a Portico valve implanted over a CoreValve bioprosthesis</atitle><jtitle>Revista portuguesa de cardiologia</jtitle><addtitle>Rev Port Cardiol</addtitle><date>2017-03</date><risdate>2017</risdate><volume>36</volume><issue>3</issue><spage>215.e1</spage><epage>215.e4</epage><pages>215.e1-215.e4</pages><issn>0870-2551</issn><eissn>2174-2030</eissn><abstract>Transcatheter aortic valve implantation (TAVI) has become an important treatment in high surgical risk patients with severe aortic stenosis (AS), whose complications need to be managed promptly. The authors report the case of an 86-year-old woman presenting with severe symptomatic AS, rejected for surgery due to advanced age and comorbidities. The patient underwent a first TAVI, with implantation of a Medtronic CoreValve®, which became dislodged and migrated to the ascending aorta. Due to the previous balloon valvuloplasty, the patient's AS became moderate, and her symptoms improved. After several months, she required another intervention, performed with a St. Jude Portico® repositionable self-expanding transcatheter aortic valve. There was a good clinical response that was maintained at one-year follow-up. The use of a self-expanding transcatheter bioprosthesis with repositioning features is a solution in cases of valve dislocation to avoid suboptimal positioning of a second implant, especially when the two valves have to be positioned overlapping or partially overlapping each other. A implantação de válvula aórtica percutânea (VAP) tornou-se um procedimento importante no tratamento de doentes com estenose aórtica grave com elevado risco cirúrgico, cujas complicações devem ser avaliadas e tratadas de forma adequada. Os autores relatam o caso de uma doente de 86 anos, com estenose aórtica grave sintomática, recusada para intervenção cirúrgica dada a idade avançada e comorbilidades. A doente foi submetida a uma primeira implantação de VAP com uma válvula Medtronic CoreValve®, a qual sofreu um deslocamento para a aorta ascendente durante o procedimento. Devido à angioplastia de balão previamente efetuada, a estenose aórtica tornou-se moderada, com melhoria da sintomatologia da doente. Vários meses depois, por agravamento clínico, houve necessidade de reintervenção, a qual foi realizada com um sistema reposicionável Portico®. Verificou-se um segundo posicionamento valvular adequado, com boa resposta clínica da doente, que persiste após um ano de follow-up. A utilização de sistemas reposicionáveis de implantação de VAP constitui, atualmente, uma solução em casos de deslocamento da válvula, de forma a evitar uma segunda implantação subótima, sobretudo quando as duas válvulas têm de ficar em sobreposição.</abstract><cop>Portugal</cop><pub>Elsevier España, S.L.U</pub><pmid>28259370</pmid><doi>10.1016/j.repc.2016.03.012</doi><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0870-2551
ispartof Revista portuguesa de cardiologia, 2017-03, Vol.36 (3), p.215.e1-215.e4
issn 0870-2551
2174-2030
language eng
recordid cdi_doaj_primary_oai_doaj_org_article_02ae1ca2ad684947bcd6468fa266649a
source ScienceDirect Journals
subjects Aged, 80 and over
Aortic Valve Stenosis - surgery
Bioprosthesis
Complicações da válvula aórtica percutânea
Deslocamento da válvula
Estenose aórtica grave
Female
Heart Valve Prosthesis
Humans
Postoperative Complications - surgery
Prosthesis Design
Prosthesis Failure
Severe aortic stenosis
Transcatheter aortic valve implantation complications
Transcatheter Aortic Valve Replacement - methods
Valve dislocation
title Sequential transcatheter aortic valve implantation due to valve dislodgement - a Portico valve implanted over a CoreValve bioprosthesis
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-20T07%3A05%3A41IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_doaj_&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Sequential%20transcatheter%20aortic%20valve%20implantation%20due%20to%20valve%20dislodgement%20-%20a%20Portico%20valve%20implanted%20over%20a%20CoreValve%20bioprosthesis&rft.jtitle=Revista%20portuguesa%20de%20cardiologia&rft.au=Campante%20Teles,%20Rui&rft.date=2017-03&rft.volume=36&rft.issue=3&rft.spage=215.e1&rft.epage=215.e4&rft.pages=215.e1-215.e4&rft.issn=0870-2551&rft.eissn=2174-2030&rft_id=info:doi/10.1016/j.repc.2016.03.012&rft_dat=%3Cproquest_doaj_%3E1874782207%3C/proquest_doaj_%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c422t-84c36a31853eb2ca68d0a49eb55880b901851e1fffbb452435315356dabe0e1e3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=1874782207&rft_id=info:pmid/28259370&rfr_iscdi=true