Cost-effective pediatric head and body phantoms for computed tomography dosimetry and its evaluation using pencil ion chamber and CT dose profiler
In the present work, a pediatric head and body phantom was fabricated using polymethyl methacrylate (PMMA) at a low cost when compared to commercially available phantoms for the purpose of computed tomography (CT) dosimetry. The dimensions of head and body phantoms were 10 cm diameter, 15 cm length...
Saved in:
Published in: | Journal of medical physics 2015-07, Vol.40 (3), p.170-175 |
---|---|
Main Authors: | , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c659v-a35933f1cc3a58d46d167c291f63c766df39ef29dc120ecc165b9dba7ce03ff73 |
---|---|
cites | |
container_end_page | 175 |
container_issue | 3 |
container_start_page | 170 |
container_title | Journal of medical physics |
container_volume | 40 |
creator | Saravanakumar, A Vaideki, K Govindarajan, K Jayakumar, S Devanand, B |
description | In the present work, a pediatric head and body phantom was fabricated using polymethyl methacrylate (PMMA) at a low cost when compared to commercially available phantoms for the purpose of computed tomography (CT) dosimetry. The dimensions of head and body phantoms were 10 cm diameter, 15 cm length and 16 cm diameter, 15 cm length, respectively. The dose from a 128-slice CT machine received by the head and body phantom at the center and periphery were measured using a 100 mm pencil ion chamber and 150 mm CT dose profiler (CTDP). Using these values, the weighted computed tomography dose index (CTDIw) and in turn the volumetric CTDI (CTDIv) were calculated for various combinations of tube voltage and current-time product. A similar study was carried out using standard calibrated phantom and the results have been compared with the fabricated ones to ascertain that the performance of the latter is equivalent to that of the former. Finally, CTDIv measured using fabricated and standard phantoms were compared with respective values displayed on the console. The difference between the values was well within the limits specified by Atomic Energy Regulatory Board (AERB), India. These results indicate that the cost-effective pediatric phantom can be employed for CT dosimetry. |
doi_str_mv | 10.4103/0971-6203.165073 |
format | article |
fullrecord | <record><control><sourceid>gale_doaj_</sourceid><recordid>TN_cdi_doaj_primary_oai_doaj_org_article_05060e97131e4a3d8fe033292e8c8981</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><galeid>A428732067</galeid><doaj_id>oai_doaj_org_article_05060e97131e4a3d8fe033292e8c8981</doaj_id><sourcerecordid>A428732067</sourcerecordid><originalsourceid>FETCH-LOGICAL-c659v-a35933f1cc3a58d46d167c291f63c766df39ef29dc120ecc165b9dba7ce03ff73</originalsourceid><addsrcrecordid>eNptkk-PEyEYxidG49bVuydD4sXLVBjmHxeTTaPrJpt4Wc-EwsuU7gxUYNr0a_iJZdq1bk0zh0ng9zwvPDxZ9p7geUkw_YxZQ_K6wHRO6go39EU2I4y1OWWEvsxmp-2r7E0Ia4zLipXl6-yqSDQucTnLfi9ciDloDTKaLaANKCOiNxKtQCgkrEJLp_ZosxI2uiEg7TySbtiMERRKK67zYrPaI-WCGSD6_UFjYkCwFf0oonEWjcHYLnlbaXo0LciVGJbgD-ziYRKn0d5p04N_m73Sog_w7ul_nf389vVh8T2__3F7t7i5z2VdsW0uaMUo1URKKqpWlbUidSMLRnRNZVPXSlMGumBKkgKDlCmhJVNL0UjAVOuGXmd3R1_lxJpvvBmE33MnDD8sON9x4aORPXBc4RpDSpMSKAVVrU4etGAFtLJlLUleX45em3E5gJJgoxf9men5jjUr3rktn16EttNhPj0ZePdrhBD5YIKEvhcW3Bg4aYqGsQrTadbH_9C1G71NUSWKNJiwljX_qE6kCxirXZorJ1N-UxZpYoHricovUB1YSId0FqYHOefnF_j0KRiMvCjAR4H0LgQP-pQJwXzqMJ9KyqeS8mOHk-TD8yxPgr-lTcDtEdi5PoIPj_24A88T-2jd7sw4f2ac0sH8rO70D7LvA78</addsrcrecordid><sourcetype>Open Website</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1717019897</pqid></control><display><type>article</type><title>Cost-effective pediatric head and body phantoms for computed tomography dosimetry and its evaluation using pencil ion chamber and CT dose profiler</title><source>PMC (PubMed Central)</source><source>Medknow Open Access Medical Journals</source><source>Publicly Available Content (ProQuest)</source><source>IngentaConnect Journals</source><creator>Saravanakumar, A ; Vaideki, K ; Govindarajan, K ; Jayakumar, S ; Devanand, B</creator><creatorcontrib>Saravanakumar, A ; Vaideki, K ; Govindarajan, K ; Jayakumar, S ; Devanand, B</creatorcontrib><description>In the present work, a pediatric head and body phantom was fabricated using polymethyl methacrylate (PMMA) at a low cost when compared to commercially available phantoms for the purpose of computed tomography (CT) dosimetry. The dimensions of head and body phantoms were 10 cm diameter, 15 cm length and 16 cm diameter, 15 cm length, respectively. The dose from a 128-slice CT machine received by the head and body phantom at the center and periphery were measured using a 100 mm pencil ion chamber and 150 mm CT dose profiler (CTDP). Using these values, the weighted computed tomography dose index (CTDIw) and in turn the volumetric CTDI (CTDIv) were calculated for various combinations of tube voltage and current-time product. A similar study was carried out using standard calibrated phantom and the results have been compared with the fabricated ones to ascertain that the performance of the latter is equivalent to that of the former. Finally, CTDIv measured using fabricated and standard phantoms were compared with respective values displayed on the console. The difference between the values was well within the limits specified by Atomic Energy Regulatory Board (AERB), India. These results indicate that the cost-effective pediatric phantom can be employed for CT dosimetry.</description><identifier>ISSN: 0971-6203</identifier><identifier>EISSN: 1998-3913</identifier><identifier>DOI: 10.4103/0971-6203.165073</identifier><identifier>PMID: 26500404</identifier><language>eng</language><publisher>India: Medknow Publications Pvt Ltd</publisher><subject>CAT scans ; CT dose profiler ; CTDI phantom ; Dosimetry ; Pediatric CT ; pediatric radiation dose ; Pediatrics ; pencil ion chamber ; Quality ; Scanners ; Sensors ; Software ; Studies ; Technical Note</subject><ispartof>Journal of medical physics, 2015-07, Vol.40 (3), p.170-175</ispartof><rights>COPYRIGHT 2015 Medknow Publications and Media Pvt. Ltd.</rights><rights>Copyright Medknow Publications & Media Pvt Ltd 2015</rights><rights>Copyright: © 2015 Journal of Medical Physics 2015</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c659v-a35933f1cc3a58d46d167c291f63c766df39ef29dc120ecc165b9dba7ce03ff73</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC4594387/pdf/$$EPDF$$P50$$Gpubmedcentral$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://www.proquest.com/docview/1717019897?pq-origsite=primo$$EHTML$$P50$$Gproquest$$Hfree_for_read</linktohtml><link.rule.ids>230,314,723,776,780,881,25731,27435,27901,27902,36989,36990,44566,53766,53768</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/26500404$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Saravanakumar, A</creatorcontrib><creatorcontrib>Vaideki, K</creatorcontrib><creatorcontrib>Govindarajan, K</creatorcontrib><creatorcontrib>Jayakumar, S</creatorcontrib><creatorcontrib>Devanand, B</creatorcontrib><title>Cost-effective pediatric head and body phantoms for computed tomography dosimetry and its evaluation using pencil ion chamber and CT dose profiler</title><title>Journal of medical physics</title><addtitle>J Med Phys</addtitle><description>In the present work, a pediatric head and body phantom was fabricated using polymethyl methacrylate (PMMA) at a low cost when compared to commercially available phantoms for the purpose of computed tomography (CT) dosimetry. The dimensions of head and body phantoms were 10 cm diameter, 15 cm length and 16 cm diameter, 15 cm length, respectively. The dose from a 128-slice CT machine received by the head and body phantom at the center and periphery were measured using a 100 mm pencil ion chamber and 150 mm CT dose profiler (CTDP). Using these values, the weighted computed tomography dose index (CTDIw) and in turn the volumetric CTDI (CTDIv) were calculated for various combinations of tube voltage and current-time product. A similar study was carried out using standard calibrated phantom and the results have been compared with the fabricated ones to ascertain that the performance of the latter is equivalent to that of the former. Finally, CTDIv measured using fabricated and standard phantoms were compared with respective values displayed on the console. The difference between the values was well within the limits specified by Atomic Energy Regulatory Board (AERB), India. These results indicate that the cost-effective pediatric phantom can be employed for CT dosimetry.</description><subject>CAT scans</subject><subject>CT dose profiler</subject><subject>CTDI phantom</subject><subject>Dosimetry</subject><subject>Pediatric CT</subject><subject>pediatric radiation dose</subject><subject>Pediatrics</subject><subject>pencil ion chamber</subject><subject>Quality</subject><subject>Scanners</subject><subject>Sensors</subject><subject>Software</subject><subject>Studies</subject><subject>Technical Note</subject><issn>0971-6203</issn><issn>1998-3913</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2015</creationdate><recordtype>article</recordtype><sourceid>PIMPY</sourceid><sourceid>DOA</sourceid><recordid>eNptkk-PEyEYxidG49bVuydD4sXLVBjmHxeTTaPrJpt4Wc-EwsuU7gxUYNr0a_iJZdq1bk0zh0ng9zwvPDxZ9p7geUkw_YxZQ_K6wHRO6go39EU2I4y1OWWEvsxmp-2r7E0Ia4zLipXl6-yqSDQucTnLfi9ciDloDTKaLaANKCOiNxKtQCgkrEJLp_ZosxI2uiEg7TySbtiMERRKK67zYrPaI-WCGSD6_UFjYkCwFf0oonEWjcHYLnlbaXo0LciVGJbgD-ziYRKn0d5p04N_m73Sog_w7ul_nf389vVh8T2__3F7t7i5z2VdsW0uaMUo1URKKqpWlbUidSMLRnRNZVPXSlMGumBKkgKDlCmhJVNL0UjAVOuGXmd3R1_lxJpvvBmE33MnDD8sON9x4aORPXBc4RpDSpMSKAVVrU4etGAFtLJlLUleX45em3E5gJJgoxf9men5jjUr3rktn16EttNhPj0ZePdrhBD5YIKEvhcW3Bg4aYqGsQrTadbH_9C1G71NUSWKNJiwljX_qE6kCxirXZorJ1N-UxZpYoHricovUB1YSId0FqYHOefnF_j0KRiMvCjAR4H0LgQP-pQJwXzqMJ9KyqeS8mOHk-TD8yxPgr-lTcDtEdi5PoIPj_24A88T-2jd7sw4f2ac0sH8rO70D7LvA78</recordid><startdate>20150701</startdate><enddate>20150701</enddate><creator>Saravanakumar, A</creator><creator>Vaideki, K</creator><creator>Govindarajan, K</creator><creator>Jayakumar, S</creator><creator>Devanand, B</creator><general>Medknow Publications Pvt Ltd</general><general>Medknow Publications and Media Pvt. Ltd</general><general>Medknow Publications & Media Pvt. Ltd</general><general>Medknow Publications & Media Pvt Ltd</general><general>Wolters Kluwer Medknow Publications</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>3V.</scope><scope>7X7</scope><scope>7XB</scope><scope>8FE</scope><scope>8FG</scope><scope>8FI</scope><scope>8FJ</scope><scope>8FK</scope><scope>8G5</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>ARAPS</scope><scope>AZQEC</scope><scope>BENPR</scope><scope>BGLVJ</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>FYUFA</scope><scope>GHDGH</scope><scope>GNUQQ</scope><scope>GUQSH</scope><scope>HCIFZ</scope><scope>K9.</scope><scope>M0S</scope><scope>M2O</scope><scope>MBDVC</scope><scope>P5Z</scope><scope>P62</scope><scope>PADUT</scope><scope>PIMPY</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>Q9U</scope><scope>7X8</scope><scope>5PM</scope><scope>DOA</scope></search><sort><creationdate>20150701</creationdate><title>Cost-effective pediatric head and body phantoms for computed tomography dosimetry and its evaluation using pencil ion chamber and CT dose profiler</title><author>Saravanakumar, A ; Vaideki, K ; Govindarajan, K ; Jayakumar, S ; Devanand, B</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c659v-a35933f1cc3a58d46d167c291f63c766df39ef29dc120ecc165b9dba7ce03ff73</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2015</creationdate><topic>CAT scans</topic><topic>CT dose profiler</topic><topic>CTDI phantom</topic><topic>Dosimetry</topic><topic>Pediatric CT</topic><topic>pediatric radiation dose</topic><topic>Pediatrics</topic><topic>pencil ion chamber</topic><topic>Quality</topic><topic>Scanners</topic><topic>Sensors</topic><topic>Software</topic><topic>Studies</topic><topic>Technical Note</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Saravanakumar, A</creatorcontrib><creatorcontrib>Vaideki, K</creatorcontrib><creatorcontrib>Govindarajan, K</creatorcontrib><creatorcontrib>Jayakumar, S</creatorcontrib><creatorcontrib>Devanand, B</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>ProQuest Central (Corporate)</collection><collection>ProQuest Health & Medical Collection</collection><collection>ProQuest Central (purchase pre-March 2016)</collection><collection>ProQuest SciTech Collection</collection><collection>ProQuest Technology Collection</collection><collection>Hospital Premium Collection</collection><collection>Hospital Premium Collection (Alumni Edition)</collection><collection>ProQuest Central (Alumni) (purchase pre-March 2016)</collection><collection>Research Library (Alumni Edition)</collection><collection>ProQuest Central (Alumni)</collection><collection>ProQuest Central</collection><collection>Advanced Technologies & Aerospace Collection</collection><collection>ProQuest Central Essentials</collection><collection>ProQuest Central</collection><collection>Technology Collection</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central Korea</collection><collection>Health Research Premium Collection</collection><collection>Health Research Premium Collection (Alumni)</collection><collection>ProQuest Central Student</collection><collection>Research Library Prep</collection><collection>SciTech Premium Collection</collection><collection>ProQuest Health & Medical Complete (Alumni)</collection><collection>Health & Medical Collection (Alumni Edition)</collection><collection>ProQuest Research Library</collection><collection>Research Library (Corporate)</collection><collection>ProQuest advanced technologies & aerospace journals</collection><collection>ProQuest Advanced Technologies & Aerospace Collection</collection><collection>Research Library China</collection><collection>Publicly Available Content (ProQuest)</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>ProQuest Central Basic</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><collection>DOAJ Directory of Open Access Journals</collection><jtitle>Journal of medical physics</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Saravanakumar, A</au><au>Vaideki, K</au><au>Govindarajan, K</au><au>Jayakumar, S</au><au>Devanand, B</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Cost-effective pediatric head and body phantoms for computed tomography dosimetry and its evaluation using pencil ion chamber and CT dose profiler</atitle><jtitle>Journal of medical physics</jtitle><addtitle>J Med Phys</addtitle><date>2015-07-01</date><risdate>2015</risdate><volume>40</volume><issue>3</issue><spage>170</spage><epage>175</epage><pages>170-175</pages><issn>0971-6203</issn><eissn>1998-3913</eissn><abstract>In the present work, a pediatric head and body phantom was fabricated using polymethyl methacrylate (PMMA) at a low cost when compared to commercially available phantoms for the purpose of computed tomography (CT) dosimetry. The dimensions of head and body phantoms were 10 cm diameter, 15 cm length and 16 cm diameter, 15 cm length, respectively. The dose from a 128-slice CT machine received by the head and body phantom at the center and periphery were measured using a 100 mm pencil ion chamber and 150 mm CT dose profiler (CTDP). Using these values, the weighted computed tomography dose index (CTDIw) and in turn the volumetric CTDI (CTDIv) were calculated for various combinations of tube voltage and current-time product. A similar study was carried out using standard calibrated phantom and the results have been compared with the fabricated ones to ascertain that the performance of the latter is equivalent to that of the former. Finally, CTDIv measured using fabricated and standard phantoms were compared with respective values displayed on the console. The difference between the values was well within the limits specified by Atomic Energy Regulatory Board (AERB), India. These results indicate that the cost-effective pediatric phantom can be employed for CT dosimetry.</abstract><cop>India</cop><pub>Medknow Publications Pvt Ltd</pub><pmid>26500404</pmid><doi>10.4103/0971-6203.165073</doi><tpages>6</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0971-6203 |
ispartof | Journal of medical physics, 2015-07, Vol.40 (3), p.170-175 |
issn | 0971-6203 1998-3913 |
language | eng |
recordid | cdi_doaj_primary_oai_doaj_org_article_05060e97131e4a3d8fe033292e8c8981 |
source | PMC (PubMed Central); Medknow Open Access Medical Journals; Publicly Available Content (ProQuest); IngentaConnect Journals |
subjects | CAT scans CT dose profiler CTDI phantom Dosimetry Pediatric CT pediatric radiation dose Pediatrics pencil ion chamber Quality Scanners Sensors Software Studies Technical Note |
title | Cost-effective pediatric head and body phantoms for computed tomography dosimetry and its evaluation using pencil ion chamber and CT dose profiler |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-31T04%3A58%3A13IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-gale_doaj_&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Cost-effective%20pediatric%20head%20and%20body%20phantoms%20for%20computed%20tomography%20dosimetry%20and%20its%20evaluation%20using%20pencil%20ion%20chamber%20and%20CT%20dose%20profiler&rft.jtitle=Journal%20of%20medical%20physics&rft.au=Saravanakumar,%20A&rft.date=2015-07-01&rft.volume=40&rft.issue=3&rft.spage=170&rft.epage=175&rft.pages=170-175&rft.issn=0971-6203&rft.eissn=1998-3913&rft_id=info:doi/10.4103/0971-6203.165073&rft_dat=%3Cgale_doaj_%3EA428732067%3C/gale_doaj_%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c659v-a35933f1cc3a58d46d167c291f63c766df39ef29dc120ecc165b9dba7ce03ff73%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=1717019897&rft_id=info:pmid/26500404&rft_galeid=A428732067&rfr_iscdi=true |